Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs

被引:14
|
作者
Mie, Keiichiro [1 ]
Ishimoto, Takuya [2 ]
Okamoto, Mari [1 ]
Iimori, Yasumasa [1 ]
Ashida, Kazuna [1 ]
Yoshizaki, Karin [1 ]
Nishida, Hidetaka [1 ]
Nakano, Takayoshi [2 ]
Akiyoshi, Hideo [1 ]
机构
[1] Osaka Prefecture Univ, Grad Sch Life & Environm Sci, Div Vet Sci, Lab Vet Surg,Course Vet Sci, Izumisano, Osaka, Japan
[2] Osaka Univ, Grad Sch Engn, Div Mat & Mfg Sci, Suita, Osaka, Japan
来源
PLOS ONE | 2020年 / 15卷 / 09期
基金
日本科学技术振兴机构;
关键词
MECHANICAL-PROPERTIES; OPEN REDUCTION; CORTICAL BONE; TEXTURE; COLLAGEN/APATITE; MICROSTRUCTURE; ARRANGEMENT; DISRUPTION; MINIATURE; ALIGNMENT;
D O I
10.1371/journal.pone.0237678
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Custom-made implants have recently gained attention in veterinary medicine because of their ability to properly fit animal bones having a wide variety of shapes and sizes. The effect of custom-made implants on bone soundness and the regeneration process is not yet clear. We fabricated a 3D printed Ti-6Al-4V custom-made bone plate that fits the shape of the dog radius, and placed it into the radius where an osteotomy had been made. The preferential orientation of the apatitec-axis contributes to the mechanical integrity of the bone and is a reliable measure of bone quality. We determined this parameter as well as the bone shape and bone mineral density (BMD). The bone portion which lies parallel to the bone plate exhibited bone resorption, decreased BMD, and significant degradation of apatite orientation, relative to the portion outside the plate, at 7 months after the operation. This demonstrates the presence of stress shielding in which applied stress is not transmitted to bone due to the insertion of a stiff bone plate. This reduced stress condition clearly influences the bone regeneration process. The apatite orientation in the regenerated site remained different even after 7 months of regeneration, indicating insufficient mechanical function in the regenerated portion. This is the first study in which the apatite orientation and BMD of the radius were evaluated under conditions of stress shielding in dogs. Our results suggest that assessment of bone repair by radiography can indicate the degree of restoration of BMD, but not the apatite orientation.
引用
收藏
页数:12
相关论文
共 35 条
  • [1] Vascularization in interconnected 3D printed Ti-6Al-4V foams with hydrogel matrix for biomedical bone replacement implants
    Correa, Victor L.
    Garza, Kristine M.
    Murr, Lawrence E.
    SCIENCE CHINA-MATERIALS, 2018, 61 (04) : 565 - 578
  • [2] Vascularization in interconnected 3D printed Ti-6Al-4V foams with hydrogel matrix for biomedical bone replacement implants
    Victor L.Correa
    Kristine M.Garza
    Lawrence E.Murr
    ScienceChinaMaterials, 2018, 61 (04) : 565 - 578
  • [3] Vascularization in interconnected 3D printed Ti-6Al-4V foams with hydrogel matrix for biomedical bone replacement implants
    Victor L. Correa
    Kristine M. Garza
    Lawrence E. Murr
    Science China Materials, 2018, 61 : 565 - 578
  • [4] 3D printed Ti6Al4V bone scaffolds with different pore structure effects on bone ingrowth
    Fuyuan Deng
    Linlin Liu
    Zhong Li
    Juncai Liu
    Journal of Biological Engineering, 15
  • [5] 3D printed Ti6Al4V bone scaffolds with different pore structure effects on bone ingrowth
    Deng, Fuyuan
    Liu, Linlin
    Li, Zhong
    Liu, Juncai
    JOURNAL OF BIOLOGICAL ENGINEERING, 2021, 15 (01)
  • [6] Surface-treated 3D printed Ti-6Al-4V scaffolds with enhanced bone regeneration performance: an in vivo study
    Zhang, Guangdao
    Zhao, Pengyu
    Lin, Lin
    Qin, Limei
    Huan, Zhiguang
    Leeflang, Sander
    Zadpoor, Amir A.
    Zhou, Jie
    Wu, Lin
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (01)
  • [7] In vivo analysis of post-joint-preserving surgery fracture of 3D-printed Ti-6Al-4V implant to treat bone cancer
    Jong Woong Park
    Ye Chan Shin
    Hyun Guy Kang
    Sangeun Park
    Eunhyeok Seo
    Hyokyung Sung
    Im Doo Jung
    Bio-Design and Manufacturing, 2021, 4 (04) : 879 - 888
  • [8] In vivo analysis of post-joint-preserving surgery fracture of 3D-printed Ti-6Al-4V implant to treat bone cancer
    Jong Woong Park
    Ye Chan Shin
    Hyun Guy Kang
    Sangeun Park
    Eunhyeok Seo
    Hyokyung Sung
    Im Doo Jung
    Bio-Design and Manufacturing, 2021, 4 : 879 - 888
  • [9] In vivo analysis of post-joint-preserving surgery fracture of 3D-printed Ti-6Al-4V implant to treat bone cancer
    Park, Jong Woong
    Shin, Ye Chan
    Kang, Hyun Guy
    Park, Sangeun
    Seo, Eunhyeok
    Sung, Hyokyung
    Jung, Im Doo
    BIO-DESIGN AND MANUFACTURING, 2021, 4 (04) : 879 - 888
  • [10] Microstructural and tribological characterisation of an 3D printed Ti-6Al-4V alloy under annealing treatment for prosthetic implantation
    Rizwee, Mumtaz
    Kumar, Deepak
    WELDING INTERNATIONAL, 2025,