A wide lock-in range PLL using self-calibrating technique for processors

被引:0
|
作者
Nakanishi, Jingo [1 ]
Notani, Hiromi [1 ]
Makino, Hiroshi [1 ]
Shinohara, Hirofumi [1 ]
机构
[1] Renesas Technol Corp, Adv Design Framework Dev Dept, Itami, Hyogo 6648641, Japan
关键词
D O I
10.1109/ASSCC.2005.251721
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A wide lock-in range PLL using a self-calibrating technique is proposed. This technique realizes a wide lock-in range and good jitter characteristics by performing the digital calibration at the start of the operation. However, self-calibration with a large number of digital control steps increases the test costs and circuit scale. In this paper, by estimating the margin for self-calibrating operation, the minimum number of digital control steps was determined. A PLL with a low test cost, a wide lock-in range and low jitter was designed and implemented using a 0.15 mu m 1.5 V CMOS process. The measured PLL lock-in range is 80 MHz - 630 MHz with four digital calibration steps. The peak-to-peak jitter at 380 MHz is 100 ps.
引用
收藏
页码:285 / 288
页数:4
相关论文
共 50 条
  • [41] A Low-Phase-Noise Digital Bang-Bang PLL with Fast Lock Over a Wide Lock Range
    Bertulessi, Luca
    Grimaldi, Luigi
    Cherniak, Dmytro
    Samori, Carlo
    Levantino, Salvatore
    2018 IEEE INTERNATIONAL SOLID-STATE CIRCUITS CONFERENCE - (ISSCC), 2018, : 252 - +
  • [42] Three-Dimensional Reconstruction of Target Self-Calibrating System with Nonlinear Optimization Technique
    Wang, Qiangfeng
    Cao, Yan
    Bai, Yu
    Wu, Yujia
    Wu, Qingyun
    INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2018, 32 (06)
  • [43] Self-calibrating distributed-source image reconstruction technique for diffuse optical tomography
    Yaroslavsky, I
    Yaroslavsky, A
    Battarbee, H
    BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 487 - 488
  • [44] Wide-Bandwidth Biological Impedance Spectroscopy System Based on the Digital Lock-In Technique
    Li, Nan
    Wang, Wei
    Xu, Hui
    Yu, Hongqi
    Diao, Jietao
    Li, David D. -U.
    SPECTROSCOPY LETTERS, 2013, 46 (07) : 476 - 482
  • [45] Self-calibrating d-scan: a versatile technique for measuring ultrashort laser pulses using an arbitrary pulse compressor
    Alonso, Benjamin
    Sola, Inigo J.
    Holgado, Warein
    Crespo, Helder
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2017,
  • [46] A SELF-CALIBRATING RHODIUM-IRON RESISTIVE SQUID THERMOMETER FOR THE RANGE BELOW 0.5 K
    SOULEN, RJ
    RUSBY, RL
    VANVECHTEN, D
    JOURNAL OF LOW TEMPERATURE PHYSICS, 1980, 40 (5-6) : 553 - 569
  • [47] Creating image-based VR using a self-calibrating fisheye lens
    Xiong, YL
    Turkowski, K
    1997 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1997, : 237 - 243
  • [48] Switched ratiometric lock-in amplifier enabling sub-ppm measurements in a wide frequency range
    Gervasoni, G.
    Carminati, M.
    Ferrari, G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (10):
  • [49] Self-Calibrating Transponder using Intelligent DSP Metrics for Efficient Optical Networks
    Spinnler, Bernhard
    Slovak, Juraj
    Su, Hao
    Syed, Sharfuddin
    Gumaste, Ashwin
    Bock, Harald
    2023 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXHIBITION, OFC, 2023,
  • [50] Sub-microdegree Phase Measurement Technique using Lock-in Amplifiers
    Walker, William D.
    2008 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, VOLS 1 AND 2, 2008, : 825 - 828