The feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus: a retrospective analysis of eleven patients

被引:21
|
作者
Zhang, Xin-Liang [1 ]
Huang, Da-Geng [1 ]
Wang, Xiao-Dong [1 ]
Zhu, Jin-Wen [1 ]
Li, Yi-Bing [1 ]
He, Bao-Rong [1 ]
Hao, Ding-Jun [1 ]
机构
[1] Xi An Jiao Tong Univ, Honghui Hosp, Dept Spine Surg, Hlth Sci Ctr, 76 Nanguo Rd, Xian 710054, Shaanxi, Peoples R China
关键词
Cervical atlas; Pedicle screw; Ponticulus posticus; LATERAL MASS SCREW; POSTERIOR ARCH; FIXATION; HEIGHT;
D O I
10.1007/s00586-016-4589-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Ponticulus posticus is a common anatomic variation that can be mistaken for a broad posterior arch during C1 pedicle screw placement. When the atlas lateral mass screws are placed via the posterior arch, injury to the vertebral artery may result. To our knowledge, there are few clinical studies that have analyzed the feasibility of C1 pedicle screw fixation in patients with ponticulus posticus, in clinical practice. To evaluate the feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus. Between January 2008 and January 2012, 11 consecutive patients with atlantoaxial instability, and with a ponticulus posticus at C1, underwent posterior fusion surgery in our institution. According to preoperative computed tomography (CT) reconstruction, a complete ponticulus posticus was found unilaterally in nine patients and bilaterally in two. Postoperative CT reconstructive imaging was performed to assess whether C1 pedicle screw placement was successful. Patients were followed up at regular intervals and evaluated for symptoms of ponticulus posticus syndrome. Thirteen C1 pedicles (atlas vertebral artery groove), each with a complete ponticulus posticus, were successfully inserted with thirteen 3.5- or 4.0-mm diameter pedicle screws, without resection of the bony anomaly. No intraoperative complications (venous plexus, vertebral artery, or spinal cord injury) occurred. The mean follow-up period was 21 (range 14-30) months. Postoperative CT reconstructive images showed that all 13 pedicle screws were inserted in the C1 pedicles without destruction of the atlas pedicle cortical bone. In the follow-up period, none of the patients demonstrated clinical symptoms of ponticulus posticus syndrome or developed bone fusion. Three-dimensional CT imaging should be considered prior to C1 pedicle screw fixation in patients with ponticulus posticus, to avoid mistaking the ponticulus posticus for a widened dorsal arch of the atlas. If there is no ponticulus posticus syndrome preoperatively, C1 pedicle screw fixation can be successfully performed without removing the bony anomaly.
引用
收藏
页码:1058 / 1063
页数:6
相关论文
共 50 条
  • [31] Deviation analysis for C1/2 pedicle screw placement using a three-dimensional printed drilling guide
    Wu, Xinghuo
    Liu, Rong
    Yu, Jie
    Lu, Lin
    Yang, Cao
    Shao, Zengwu
    Ye, Zhewei
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (06) : 547 - 554
  • [32] C1 Titanium Cables Combined with C2 Pedicle Screw-Rod Fixation for Atlantoaxial Instability Not Suitable for Placement of C1 Screws
    Zhang, Jie-Hong
    Zhang, Zhi-Jing
    Zhu, Ya
    Shi, Jian-Dong
    Li, Bin
    Lu, Yi-Sheng
    WORLD NEUROSURGERY, 2018, 120 : E453 - E456
  • [33] Posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial instability
    Xie, Yang
    Li, Zhonghai
    Tang, Hao
    Li, Ming
    Guan, Zhengmao
    JOURNAL OF CLINICAL NEUROSCIENCE, 2009, 16 (12) : 1592 - 1594
  • [34] Usefulness of a New Electronic Conductivity Device with a Pedicle Probe and a Multi-axis Angiography Unit for Inserting a C1 Lateral Mass Screw Safely and Tightly: A Technical Note
    Kageyama, Hiroto
    Yoshimura, Shinichi
    Matsuda, Kenichi
    Yoshida, Yasunori
    Matsukawa, Hidetoshi
    Yamada, Kiyofumi
    NEUROLOGIA MEDICO-CHIRURGICA, 2019, 59 (12) : 523 - 528
  • [35] Is the 4 mm height of the vertebral artery groove really a limitation of C1 pedicle screw insertion?
    Da-Geng Huang
    Si-Min He
    Jun-Wei Pan
    Hua Hui
    Hui-Min Hu
    Bao-Rong He
    Hui Li
    Xue-Fang Zhang
    Ding-Jun Hao
    European Spine Journal, 2014, 23 : 1109 - 1114
  • [36] Is the 4 mm height of the vertebral artery groove really a limitation of C1 pedicle screw insertion?
    Huang, Da-Geng
    He, Si-Min
    Pan, Jun-Wei
    Hui, Hua
    Hu, Hui-Min
    He, Bao-Rong
    Li, Hui
    Zhang, Xue-Fang
    Hao, Ding-Jun
    EUROPEAN SPINE JOURNAL, 2014, 23 (05) : 1109 - 1114
  • [37] Retrospective Evaluation of Patients with Angioedema Treated with C1 Inhibitors in an Emergency Department
    Yalcinli, Sercan
    Kiyan, Selahattin
    Akarca, Funda Karbek
    EURASIAN JOURNAL OF EMERGENCY MEDICINE, 2022, 21 (03) : 183 - 187
  • [38] Novel unilateral C1 double screw and ipsilateral C2 pedicle screw placement combined with contralateral laminar screw–rod fixation for atlantoaxial instability
    Lei Shi
    Kai Shen
    Rui Deng
    Zheng-Jian Yan
    Kai-Lu Liang
    Liang Chen
    Zhen-Yong Ke
    Zhong-Liang Deng
    European Spine Journal, 2019, 28 : 362 - 369
  • [39] Can C1 lateral mass and C3 pedicle screw fixation be used as an option for atlantoaxial reduction and stabilization in Klippel-Feil patients? A study of its morphological feasibility, technical nuances, and clinical efficiency
    Yue-Qi Du
    Yi-Heng Yin
    Teng Li
    Guang-Yu Qiao
    Xin-Guang Yu
    Neurosurgical Review, 2022, 45 : 2183 - 2192
  • [40] Can C1 lateral mass and C3 pedicle screw fixation be used as an option for atlantoaxial reduction and stabilization in Klippel-Feil patients? A study of its morphological feasibility, technical nuances, and clinical efficiency
    Du, Yue-Qi
    Yin, Yi-Heng
    Li, Teng
    Qiao, Guang-Yu
    Yu, Xin-Guang
    NEUROSURGICAL REVIEW, 2022, 45 (03) : 2183 - 2192