The feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus: a retrospective analysis of eleven patients

被引:21
|
作者
Zhang, Xin-Liang [1 ]
Huang, Da-Geng [1 ]
Wang, Xiao-Dong [1 ]
Zhu, Jin-Wen [1 ]
Li, Yi-Bing [1 ]
He, Bao-Rong [1 ]
Hao, Ding-Jun [1 ]
机构
[1] Xi An Jiao Tong Univ, Honghui Hosp, Dept Spine Surg, Hlth Sci Ctr, 76 Nanguo Rd, Xian 710054, Shaanxi, Peoples R China
关键词
Cervical atlas; Pedicle screw; Ponticulus posticus; LATERAL MASS SCREW; POSTERIOR ARCH; FIXATION; HEIGHT;
D O I
10.1007/s00586-016-4589-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Ponticulus posticus is a common anatomic variation that can be mistaken for a broad posterior arch during C1 pedicle screw placement. When the atlas lateral mass screws are placed via the posterior arch, injury to the vertebral artery may result. To our knowledge, there are few clinical studies that have analyzed the feasibility of C1 pedicle screw fixation in patients with ponticulus posticus, in clinical practice. To evaluate the feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus. Between January 2008 and January 2012, 11 consecutive patients with atlantoaxial instability, and with a ponticulus posticus at C1, underwent posterior fusion surgery in our institution. According to preoperative computed tomography (CT) reconstruction, a complete ponticulus posticus was found unilaterally in nine patients and bilaterally in two. Postoperative CT reconstructive imaging was performed to assess whether C1 pedicle screw placement was successful. Patients were followed up at regular intervals and evaluated for symptoms of ponticulus posticus syndrome. Thirteen C1 pedicles (atlas vertebral artery groove), each with a complete ponticulus posticus, were successfully inserted with thirteen 3.5- or 4.0-mm diameter pedicle screws, without resection of the bony anomaly. No intraoperative complications (venous plexus, vertebral artery, or spinal cord injury) occurred. The mean follow-up period was 21 (range 14-30) months. Postoperative CT reconstructive images showed that all 13 pedicle screws were inserted in the C1 pedicles without destruction of the atlas pedicle cortical bone. In the follow-up period, none of the patients demonstrated clinical symptoms of ponticulus posticus syndrome or developed bone fusion. Three-dimensional CT imaging should be considered prior to C1 pedicle screw fixation in patients with ponticulus posticus, to avoid mistaking the ponticulus posticus for a widened dorsal arch of the atlas. If there is no ponticulus posticus syndrome preoperatively, C1 pedicle screw fixation can be successfully performed without removing the bony anomaly.
引用
收藏
页码:1058 / 1063
页数:6
相关论文
共 50 条
  • [11] Feasibility and limitations of C1 lateral mass screw placement in patients of atlas assimilation
    Jian, Feng-Zeng
    Su, Chun-Hai
    Chen, Zan
    Wang, Xing-Wen
    Ling, Feng
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2012, 114 (06) : 590 - 596
  • [12] C1 anatomy and dimensions relative to pedicle screw placement
    Niu, He-Gang
    Yan, Yi-Zhu
    Zhang, Jing-Jing
    Shen, Cai-Liang
    Zhang, Yin -Shun
    JOURNAL OF CLINICAL NEUROSCIENCE, 2023, 111 : 22 - 25
  • [13] Ponticulus Posticus on the Posterior Arch of Atlas, Prevalence Analysis in Symptomatic and Asymptomatic Patients of Gulbarga Population
    Chitroda, Parita K.
    Katti, Girish
    Baba, Irfan A.
    Najmudin, Mohammad
    Ghali, Sreennas Rao
    Kalmath, Bhuvaneshwari
    Vijay, G.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2013, 7 (12) : 3044 - 3047
  • [14] Comparison of Transarticular Screw Fixation and C1 Lateral Mass-C2 Pedicle Screw Fixation in Patients with Rheumatoid Arthritis with Atlantoaxial Instability
    Ryu, Je Il
    Bak, Koang Hum
    Kim, Jae Min
    Chun, Hyoung-Joon
    WORLD NEUROSURGERY, 2017, 99 : 179 - 185
  • [15] Three-dimensional anatomic analysis and navigation templates for C1 pedicle screw placement perpendicular to the coronal plane: a retrospective study
    Wu, Chao
    Deng, Jiayan
    Zeng, Bofang
    Zhu, Yuan Fang
    Li, Tao
    NEUROLOGICAL RESEARCH, 2021, 43 (12) : 961 - 969
  • [16] C2 Pedicle Screw and Plate Combined With C1 Titanium Cable Fixation for the Treatment of Alantoaxial Instability not Suitable for Placement of C1 Screw
    Xiao, Zeng Ming
    Zhan, Xin Li
    Gong, De Feng
    Chen, Qian Fen
    Bin Lao, Gao
    Jiang, Hua
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (07): : 514 - 517
  • [17] Morphometric Analysis of C2 Pedicle in 247 Patients and Proposal for Trajectory and Size of Pedicle Screw
    Agrawal, Mohit
    Devarajan, Leve J.
    Dharanipathy, Sundarakrishnan
    Katiyar, Varidh
    Singh, Pankaj K.
    Garg, Ajay
    Chandra, P. Sarat
    Kale, Shashank S.
    NEUROLOGY INDIA, 2021, 69 (04) : 925 - 930
  • [18] Cone beam computed tomography evaluation of ponticulus posticus in patients with cleft lip and palate: a retrospective radio-anatomic study
    Bayrakdar, I. S.
    Yasa, Y.
    Duman, S. B.
    Karaturgut, U. E.
    Ocak, A.
    Yilmaz, S. Gunen
    FOLIA MORPHOLOGICA, 2018, 77 (01) : 72 - 78
  • [19] Feasibility of C2 Pedicle Screw Fixation With the "in-out-in" Technique for Patients With Basilar Invagination
    Xu, Panjie
    Lin, Junyu
    Xiao, Hang
    Zheng, Jianying
    Ji, Wei
    SPINE, 2024, 49 (11) : 798 - 804
  • [20] Feasibility of lateral mass screw insertion in patients with the risky triad of C1: evaluation of the over-the-arch technique
    Lee, Hyung Rae
    Lee, Dong-Ho
    Cho, Jae Hwan
    Hwang, Eui Seung
    Seok, Sang Yun
    Park, Sehan
    Lee, Choon Sung
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (05) : 822 - 829