Fluid pulsation detection in presence of induced motion artifacts using speckle techniques

被引:1
|
作者
Nemati, M. [1 ]
Paroni, L. G. [2 ]
Bhattacharya, N. [1 ]
Urbach, H. P. [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Sci & Technol, Opt Res Grp, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] LifeTec Grp, NL-5612 AZ Eindhoven, Netherlands
关键词
Image processing; Pulsatile flow; Scattering; Medical devices; BLOOD-FLOW; VALIDATION; DYNAMICS; VELOCITY; SIGNALS; MEDIA;
D O I
10.1063/1.4879585
中图分类号
O59 [应用物理学];
学科分类号
摘要
The importance of regular health monitoring has led to a large variety of medical products being available in the market. Motion artifact is still a limitation in portable optical devices which can provide accurate results. We will address the possibility of measuring a pulsatile flow in a noisy environment using an approach based on speckle dynamics. In specific case we measure pulsation or the heart rate in presence of motion between the illumination and the in-vitro or in-vivo sample. The main motion induced artifact in the signal being measured arises from changing the light penetration depth at various positions being illuminated. These measurements have been compared for different settings and multiple-exposure time of the camera. We compare the result for each measurement based on two techniques of speckle contrast and correlation. Under several parameters of the measurement, different analysis techniques were successful but in general correlation approach shows to be more robust for larger motion induced artifacts. Shorter exposure times provide a more detailed spectrum and more successful for extracting the signal from the induced motion artifact, in case of correlation analysis. The in-vivo measurement results agreed fairly with in-vitro case.
引用
收藏
页码:215 / 222
页数:8
相关论文
共 50 条
  • [41] Maneuvering Fluid Motion and Flow-Induced Detection of Toxins by Enzyme Multilayer Films
    Gill, Arshdeep K.
    Varshney, Rohit
    Alam, Mujeeb
    Agashe, Chinmayee
    Patra, Debabrata
    ACS APPLIED BIO MATERIALS, 2021, 4 (08): : 6203 - 6208
  • [42] Measurement of Very Low Concentration of Microparticles in Fluid by Single Particle Detection using Acoustic Radiation Force Induced Particle Motion
    Lee, John H.
    Jimenez, Javier
    Butterworth, Ian R.
    Castro-Gonzalez, Carlos
    Shukla, Shiva K.
    Marti-Fuster, Berta
    Elvira, Luis
    Boning, Duane S.
    Anthony, Brian W.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [43] Mitigation of motion-induced artifacts in cone beam computed tomography using deep convolutional neural networks
    Amirian, Mohammadreza
    Montoya-Zegarra, Javier A.
    Herzig, Ivo
    Hotz, Peter Eggenberger
    Lichtensteiger, Lukas
    Morf, Marco
    Zust, Alexander
    Paysan, Pascal
    Peterlik, Igor
    Scheib, Stefan
    Fuchslin, Rudolf Marcel
    Stadelmann, Thilo
    Schilling, Frank-Peter
    MEDICAL PHYSICS, 2023, 50 (10) : 6228 - 6242
  • [44] Detection of apparent skin motion using optical flow analysis: Blood pulsation signal obtained from optical flow sequence
    Nakajima, K
    Maekawa, T
    Miike, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (02): : 1331 - 1336
  • [45] Speckle tracking in a phantom and feature-based tracking in liver in the presence of respiratory motion using 4D ultrasound
    Harris, Emma J.
    Miller, Naomi R.
    Bamber, Jeffrey C.
    Symonds-Tayler, J. Richard N.
    Evans, Philip M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12): : 3363 - 3380
  • [46] Breast Tumor Detection and Classification Using Intravoxel Incoherent Motion Hyperspectral Imaging Techniques
    Chan, Si-Wa
    Chang, Yung-Chieh
    Huang, Po-Wen
    Ouyang, Yen-Chieh
    Chang, Yu-Tzu
    Chang, Ruey-Feng
    Chai, Jyh-Wen
    Chen, Clayton Chi-Chang
    Chen, Hsian-Min
    Chang, Chein-, I
    Lin, Chin-Yao
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [47] Foreground Estimation in Motion Imagery Using Multi-Frame Change Detection Techniques
    Lingg, Andrew J.
    Rigling, Brian D.
    MOTION IMAGERY TECHNOLOGIES, BEST PRACTICES, AND WORKFLOWS FOR INTELLIGENCE, SURVEILLANCE, AND RECONNAISSANCE (ISR), AND SITUATIONAL AWARENESS, 2013, 8740
  • [48] Motion capture of chest and abdominal markers using a flexible multi-camera motion-tracking system for correcting motion-induced artifacts in cardiac SPECT
    McNamara, Joseph E.
    Feng, Bing
    Johnson, Karen
    Gu, Sonxiang
    Gennert, Michael A.
    King, Michael A.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4289 - +
  • [49] Control of Body Motion in an Ideal Fluid Using the Internal Mass and the Rotor in the Presence of Circulation Around the Body
    Evgeny V. Vetchanin
    Alexander A. Kilin
    Journal of Dynamical and Control Systems, 2017, 23 : 435 - 458
  • [50] Control of Body Motion in an Ideal Fluid Using the Internal Mass and the Rotor in the Presence of Circulation Around the Body
    Vetchanin, Evgeny V.
    Kilin, Alexander A.
    JOURNAL OF DYNAMICAL AND CONTROL SYSTEMS, 2017, 23 (02) : 435 - 458