Fluid pulsation detection in presence of induced motion artifacts using speckle techniques

被引:1
|
作者
Nemati, M. [1 ]
Paroni, L. G. [2 ]
Bhattacharya, N. [1 ]
Urbach, H. P. [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Sci & Technol, Opt Res Grp, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] LifeTec Grp, NL-5612 AZ Eindhoven, Netherlands
关键词
Image processing; Pulsatile flow; Scattering; Medical devices; BLOOD-FLOW; VALIDATION; DYNAMICS; VELOCITY; SIGNALS; MEDIA;
D O I
10.1063/1.4879585
中图分类号
O59 [应用物理学];
学科分类号
摘要
The importance of regular health monitoring has led to a large variety of medical products being available in the market. Motion artifact is still a limitation in portable optical devices which can provide accurate results. We will address the possibility of measuring a pulsatile flow in a noisy environment using an approach based on speckle dynamics. In specific case we measure pulsation or the heart rate in presence of motion between the illumination and the in-vitro or in-vivo sample. The main motion induced artifact in the signal being measured arises from changing the light penetration depth at various positions being illuminated. These measurements have been compared for different settings and multiple-exposure time of the camera. We compare the result for each measurement based on two techniques of speckle contrast and correlation. Under several parameters of the measurement, different analysis techniques were successful but in general correlation approach shows to be more robust for larger motion induced artifacts. Shorter exposure times provide a more detailed spectrum and more successful for extracting the signal from the induced motion artifact, in case of correlation analysis. The in-vivo measurement results agreed fairly with in-vitro case.
引用
收藏
页码:215 / 222
页数:8
相关论文
共 50 条
  • [31] Cancellation of motion artifacts in ambulatory ECG signals using TD-LMS adaptive filtering techniques
    Xiong, Fan
    Chen, Dongyi
    Chen, Zhenghao
    Dai, Shumei
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2019, 58 : 606 - 618
  • [32] Simulation of motion of gastric fluid induced by peristalsis using CFD
    Kozu, Hiroyuki
    Kobayashi, Isao
    Nakajima, Mitsutoshi
    Uemura, Kunihiko
    Sato, Seigo
    Ichikawa, Sosaku
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2009, 108 : S136 - S136
  • [33] Measuring Breast Motion at Multiple DBT Compression Levels Using Ultrasound Speckle-tracking Techniques
    Zeng, Rongping
    Jia, Congxian
    Akhlaghi, Nima
    Torkaman, Mahsa
    Garra, Brian
    Alton, Karen
    Brem, Rachel
    Ahmed, Tahira
    Kaczmarek, Richard
    Myers, Kyle J.
    14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [34] Motion Detection in the Presence of Egomotion Using the Fourier-Mellin Transform
    Thoduka, Santosh
    Hegger, Frederik
    Kraetzschmar, Gerhard K.
    Ploeger, Paul G.
    ROBOCUP 2017: ROBOT WORLD CUP XXI, 2018, 11175 : 252 - 264
  • [35] Correction of Motion-Induced Artifacts in Clinical Cardiac SPECT Studies Using a Stereo-Motion-Tracking System
    McNamara, Joseph E.
    Johnson, Karen
    Mitra, Joyeeta
    Pretorius, P. Hendrik
    Gu, Sonxiang
    Gennert, Michael A.
    King, Michael A.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3593 - +
  • [36] HUMAN DETECTION AND MOTION TRACKING USING MACHINE LEARNING TECHNIQUES: A REVIEW
    Mahajan, Rohini
    Padha, Devanand
    2018 FIFTH INTERNATIONAL CONFERENCE ON PARALLEL, DISTRIBUTED AND GRID COMPUTING (IEEE PDGC), 2018, : 127 - 131
  • [37] IMPROVED MR IMAGING OF THE BRAIN BY USING COMPENSATING GRADIENTS TO SUPPRESS MOTION-INDUCED ARTIFACTS
    QUENCER, RM
    HINKS, RS
    PATTANY, PH
    HOREN, M
    POST, MJD
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (03) : 431 - 438
  • [38] IMPROVED MR IMAGING OF THE BRAIN BY USING COMPENSATING GRADIENTS TO SUPPRESS MOTION-INDUCED ARTIFACTS
    QUENCER, RM
    HINKS, RS
    PATTANY, PH
    HOREN, M
    POST, MJD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (01) : 163 - 170
  • [39] NONDESTRUCTIVE DETECTION OF DEFECTS IN MINIATURIZED MULTILAYER CERAMIC CAPACITORS USING DIGITAL SPECKLE CORRELATION TECHNIQUES
    CHAN, YC
    YEUNG, F
    JIN, GC
    BAO, NK
    CHUNG, PS
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART A, 1995, 18 (03): : 677 - 684
  • [40] A comparison of multidimensional flow estimation techniques using computational fluid dynamics: speckle tracking versus vector Doppler
    Swillens, Abigail
    Segers, Patrick
    Lovstakken, Lasse
    Torp, Hans
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1623 - +