CCD-Based Temperature Modulated Fluorescence Tomography

被引:3
|
作者
Mehrabi, Mehrnaz [1 ,2 ]
Nouizi, Farouk [1 ]
Algarawi, Maha [1 ]
Kwong, Tiffany C. [1 ]
Erkol, Hakan [3 ]
Sampathkumaran, Uma [4 ]
Gulsen, Gultekin [1 ,2 ]
机构
[1] Univ Calif Irvine, Ctr Funct Oncoimaging, Irvine, CA 92717 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92717 USA
[3] Bogazici Univ, Istanbul, Turkey
[4] InnoSense LLC, 2531 West 237th St,Suite 12, Torrance, CA 90505 USA
基金
美国国家卫生研究院;
关键词
Fluorescence tomography; Optical imaging; Focused ultrasound; Multimodality imaging; Indocyanine green (ICG); Thermo-sensitive fluorescence agents; Temperature modulated fluorescence tomography (TMFT); Near-infrared probes; Image reconstruction techniques; diffuse optics; Medical imaging; QUANTITATIVE ACCURACY; RESOLUTION; ALGORITHM;
D O I
10.1117/12.2508931
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High scattering in biological tissues severely degrades the spatial resolution of optical fluorescence imaging in thick tissue. As one of the most sensitive in vivo molecular imaging modalities, Fluorescence Tomography plays an essential role in preclinical studies. To overcome the limitations of FT, we introduced a novel method termed, temperature modulated fluorescence tomography (TMFT). TMFT is based on two key elements: 1) temperature sensitive fluorescent agent (ThermoDots) and 2) high intensity focused ultrasound (HIFU). TMFT localizes the position of the fluorescent ThermoDots by scanning a HIFU beam across the tissue while monitoring the variation in the measured fluorescence signals Actually, a binary mask is built by monitoring the sudden jumps in the fluorescence signal corresponding to the HIFU scan over a position containing ThermoDots. This binary map is used as functional a priori during the FT image reconstruction process. TMFT not only allowed us to resolve ThermoDots with high spatial resolution (similar to 1.3 mm), deep in tissue (similar to 60 mm) but with high quantitative accuracy as well (< 3% error). In this paper, we present the latest prototype of TMFT. Here, the fluorescence signals are acquired using a CCD camera, which increases the sensitivity of the system compared to the previous fiber-based system.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Development of a preclinical CCD- based temperature modulated fluorescence tomography platform
    Nouizi, Farouk
    Erkol, Hakan
    Nikkhah, Deniz
    Kwong, Tiffany C.
    Gulsen, Gultekin
    [J]. BIOMEDICAL OPTICS EXPRESS, 2022, 13 (11) : 5740 - 5752
  • [2] Fast ICCD-based temperature modulated fluorescence tomography
    Nouizi, Farouk
    Kwong, Tiffany C.
    Turong, Bryan
    Nikkhah, Deniz
    Sampathkumaran, Uma
    Gulsen, Gultekin
    [J]. APPLIED OPTICS, 2023, 62 (28) : 7420 - 7430
  • [3] COMBINED RAMAN AND FLUORESCENCE SPECTROSCOPY WITH THE SAME COMPACT CCD-BASED INSTRUMENT
    HOFFMANN, GG
    MENZEBACH, HU
    OELICHMANN, B
    SCHRADER, B
    [J]. APPLIED SPECTROSCOPY, 1992, 46 (04) : 568 - 570
  • [4] A CCD-based detector for SPECT
    Nagarkar, VV
    Shestakova, I
    Gaysinskiy, V
    Tipnis, SV
    Singh, B
    Barber, W
    Hasegawa, B
    Entine, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 54 - 58
  • [5] CCD-based vertex detectors
    Damerell, CJS
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 541 (1-2): : 178 - 188
  • [6] A CCD-based γ-ray dosimeter
    Harris, EJ
    Royle, GJ
    Mooney, MJ
    Speller, RD
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 227 - 232
  • [7] OPTIMIZATION OF CCD-BASED ENERGY-MODULATED X-RAY MICROTOMOGRAPHY
    BONSE, U
    NUSSHARDT, R
    BUSCH, F
    PAHL, R
    JOHNSON, QC
    KINNEY, JH
    SAROYAN, RA
    NICHOLS, MC
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2478 - 2481
  • [8] A CCD-based detector for SPECT
    Nagarkar, VV
    Shestakova, I
    Gaysinskiy, V
    Tipnis, SV
    Singh, B
    Barber, W
    Hasegawa, B
    Entine, G
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2449 - 2452
  • [9] An adaptive algorithm for gamma spots removal in CCD-based neutron radiography and tomography
    Li, Hongyun
    Schillinger, Burkhard
    Calzada, Elbio
    Liu Yinong
    Muehlbauer, Martin
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 564 (01): : 405 - 413
  • [10] Development of a CCD-based pyrometer for surface temperature measurement of casting billets
    Zhang, Yuzhong
    Lang, Xianli
    Hu, Zhenwei
    Shu, Shuangbao
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (06)