A CCD-based γ-ray dosimeter

被引:1
|
作者
Harris, EJ
Royle, GJ
Mooney, MJ
Speller, RD
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6JA, England
[2] British Energy Generat Ltd, Nucl Elect, Gloucester GL4 3RS, England
关键词
CCD; dosimetry;
D O I
10.1016/S0168-9002(00)00866-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper investigates the use of charged coupled devices (CCDs) for personal gamma -ray dosimetry. Personal dosimeters require high sensitivity to the photon energies likely to be encountered and a sensitivity response across a wide dose rate range, particularly at low dose rates. The principal advantages of CCDs for this application are two-fold: sensitivity at low dose rates due to low-noise operation and a wide dynamic range. Preliminary experimental measurements have been performed on a standard buried channel CCD using a range of isotope sources. One half of the sensor was coated with a 100 mum thick layer of caesium iodide. It is proposed that the differing properties of the two halves of the sensor increases its range for personal dosimetry. Deposition of scintillator coatings of various thicknesses across the surface of the sensor should provide sensitivity to a wide energy range. The results demonstrated that the device has potential for this application. A linear dose rate response was observed over the dose rate range 0.08-35 mu Sv h(-1). It was found that the uncoated side of the sensor demonstrated better response at low dose rates and a better energy response. Whereas the scintillator coated side would improve the detection efficiency at energies beyond 60keV. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:227 / 232
页数:6
相关论文
共 50 条
  • [1] Developments in CCD-based beta/X-ray imaging
    Wells, K
    Kokkinou, E
    Petrou, M
    Ranicar, A
    Spinks, T
    Ott, RJ
    [J]. PENETRATING RADIATION SYSTEMS AND APPLICATIONS III, 2001, 4508 : 99 - 110
  • [2] Soft X-ray spectrograph with CCD-Based detector
    Volkov, GS
    Zaitsev, VI
    AttelanLanglet, S
    Mishenskii, VO
    Papazyan, YV
    Fedulov, MV
    Smirnov, VP
    Etlicher, B
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1997, 40 (01) : 113 - 117
  • [3] A CCD-based detector for SPECT
    Nagarkar, VV
    Shestakova, I
    Gaysinskiy, V
    Tipnis, SV
    Singh, B
    Barber, W
    Hasegawa, B
    Entine, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 54 - 58
  • [4] CCD-based vertex detectors
    Damerell, CJS
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 541 (1-2): : 178 - 188
  • [5] High-sensitivity CCD-based X-ray detector
    Phillips, WC
    Stewart, A
    Stanton, M
    Naday, I
    Ingersoll, C
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 36 - 43
  • [6] A CCD-based detector for SPECT
    Nagarkar, VV
    Shestakova, I
    Gaysinskiy, V
    Tipnis, SV
    Singh, B
    Barber, W
    Hasegawa, B
    Entine, G
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2449 - 2452
  • [7] Performance of scintillating waveguides for CCD-based X-ray detectors
    Badel, X
    Norlin, B
    Kleimann, P
    Williams, L
    Moody, SJ
    Tyrrell, GC
    Fröjdh, C
    Linnros, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 3 - 8
  • [8] A CCD-BASED VERTEX DETECTOR FOR SLD
    DAMERELL, CJS
    ENGLISH, RL
    GILLMAN, AR
    LINTERN, AL
    PHILLIPS, D
    SU, D
    WICKENS, FJ
    AGNEW, G
    CLARKE, P
    HEDGES, S
    MCKEMEY, A
    WATTS, SJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01): : 236 - 239
  • [9] Realization of systems with CCD-based measurements
    Looze, DP
    [J]. AUTOMATICA, 2005, 41 (11) : 2005 - 2009
  • [10] CHARACTERIZATION OF CCD-BASED IMAGING X-RAY-DETECTORS FOR DIFFRACTION EXPERIMENTS
    NADAY, I
    ROSS, S
    KANYO, M
    WESTBROOK, E
    WESTBROOK, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3): : 534 - 538