Rapid Detection of Mycoplasma pneumoniae by Loop-Mediated Isothermal Amplification (LAMP) in Clinical Respiratory Specimens

被引:1
|
作者
Arfaatabar, Maryam [1 ]
Noori Goodarzi, Narjes [1 ]
Afshar, Davoud [2 ]
Memariani, Hamed [3 ]
Azimi, Ghasem [4 ]
Masoorian, Ensieh [1 ]
Pourmand, Mohammad Reza [1 ,5 ]
机构
[1] Univ Tehran Med Sci, Sch Publ Hlth, Dept Pathobiol, Tehran, Iran
[2] Zanjan Univ Med Sci, Sch Med, Dept Microbiol & Virol, Zanjan, Iran
[3] Pasteur Inst Iran, Biotechnol Res Ctr, Tehran, Iran
[4] Shahed Univ Med Sci, Dept Internal Med, Tehran, Iran
[5] Univ Tehran Med Sci, Biotechnol Res Ctr, Tehran, Iran
关键词
Mycoplasma pneumoniae; PCR; Loop-mediated isothermal amplification (LAMP); Culture; DIAGNOSIS; ASSAY; CHILDREN; DNA;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Mycoplasma pneumoniae is a common cause of community-acquired pneumonia (CAP) worldwide, especially among children and debilitated populations. The present study aimed to investigate a loop-mediated isothermal amplification (LAMP) technique for rapid detection of M. pneumoniae in clinical specimens collected from patients with pneumonia. Methods: Throat swabs were collected from 110 outpatients who suffered from pneumonia. Throat swab samples were obtained from patients referred to the hospital outpatient clinics of Tehran University hospitals, Iran in 2017. The presence of M. pneumoniae in the clinical specimens was evaluated by LAMP, PCR and culture methods. Sensitivity and specificity of the LAMP and PCR assays were also determined. Results: Out of 110 specimens, LAMP assay detected M. pneumoniae in 35 specimens. Detection limit of the LAMP assay was determined to be 33fg /mu L or similar to 40 genome copies/reaction. Moreover, no cross-reaction with genomic DNA from other bacteria was observed. Only 25 specimens were positive by the culture method. The congruence between LAMP assay and culture method was 'substantial' (x=0.77). Specificity and sensitivity of LAMP assay were 88.2%, 100% in compare with culture. However, the congruence between LAMP assay and PCR assay was 'almost perfect' (x=0.86). Specificity and sensitivity of LAMP assay were 92.5%, 100% in compare with PCR. Conclusion: Overall, the LAMP assay is a rapid and cost-efficient laboratory test in comparison to other methods including PCR and culture. Therefore, the LAMP method can be applied in identification of M. pneumoniae isolates in respiratory specimens.
引用
收藏
页码:917 / 924
页数:8
相关论文
共 50 条
  • [1] Rapid detection of Mycoplasma pneumoniae CARDS toxin in clinical respiratory specimens by a loop-mediated isothermal amplification assay
    Fang, Yun
    Xie, Panpan
    Zhang, Xin
    Zhang, Yue
    Yang, Ning
    Shi, Yinghui
    Xin, Ruixia
    Bai, Yunbiao
    Niu, Wenkai
    Yuan, Xin
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2025, 15
  • [2] Loop-mediated isothermal amplification (LAMP) for the rapid detection of Mycoplasma genitalium
    Edwards, Thomas
    Burke, Patricia
    Smalley, Helen B.
    Gillies, Liz
    Longhurst, Denise
    Vipond, Barry
    Hobbs, Glyn
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2015, 83 (01) : 13 - 17
  • [3] Rapid detection of Mycoplasma pneumoniae by loop-mediated isothermal amplification assay
    Yuan, Xin
    Bai, Changqing
    Cui, Qian
    Zhang, Han
    Yuan, Jing
    Niu, Kaiwen
    Feng, Yuzhong
    Jin, Xin
    Li, Puyuan
    Liu, Huiying
    MEDICINE, 2018, 97 (25)
  • [4] DETECTION OF MYCOPLASMA PNEUMONIAE BY COLORIMETRIC LOOP-MEDIATED ISOTHERMAL AMPLIFICATION
    Zhao, Fei
    Liu, Zhong
    Gu, Yixin
    Yang, Yuelian
    Xiao, Di
    Tao, Xiaoxia
    Meng, Fanliang
    He, Lihua
    Zhang, Jianzhong
    ACTA MICROBIOLOGICA ET IMMUNOLOGICA HUNGARICA, 2013, 60 (01) : 1 - 9
  • [5] Rapid detection of hemolysin gene of Klebsiella pneumoniae by Loop-Mediated Isothermal Amplification (LAMP)
    Pasupathi, Rathinasabapathi
    RESEARCH JOURNAL OF BIOTECHNOLOGY, 2018, 13 (04): : 24 - 28
  • [6] ISFET Biosensor with Loop-Mediated Isothermal Amplification for Electronic Rapid Detection of Mycoplasma Pneumoniae
    Zou, Jie
    Hu, Jie
    Shen, Yan
    Zhang, Limei
    Bai, Weiyi
    Wang, Lei
    Li, Jianlong
    Yan, Lin
    Zhang, Zhifeng
    Bai, Hao
    Hu, Wenchuang
    SENSORS, 2025, 25 (05)
  • [7] Clinical utility of loop-mediated isothermal amplification for rapid diagnosis of Mycoplasma pneumoniae in children
    Aizawa, Yuta
    Oishi, Tomohiro
    Tsukano, Shinya
    Taguchi, Tetsuo
    Saitoh, Akihiko
    JOURNAL OF MEDICAL MICROBIOLOGY, 2014, 63 : 248 - 251
  • [8] Rapid detection of Mycoplasma synoviae by loop-mediated isothermal amplification
    Olimpia Kursa
    Grzegorz Woźniakowski
    Grzegorz Tomczyk
    Anna Sawicka
    Zenon Minta
    Archives of Microbiology, 2015, 197 : 319 - 325
  • [9] Rapid detection of Mycoplasma synoviae by loop-mediated isothermal amplification
    Kursa, Olimpia
    Wozniakowski, Grzegorz
    Tomczyk, Grzegorz
    Sawicka, Anna
    Minta, Zenon
    ARCHIVES OF MICROBIOLOGY, 2015, 197 (02) : 319 - 325
  • [10] Rapid detection of the Klebsiella pneumoniae carbapenemase (KPC) gene by loop-mediated isothermal amplification (LAMP)
    Nakano, Ryuichi
    Nakano, Akiyo
    Ishii, Yoshikazu
    Ubagai, Tsuneyuki
    Kikuchi-Ueda, Takane
    Kikuchi, Hirotoshi
    Tansho-Nagakawa, Shigeru
    Kamoshida, Go
    Mu, Xiaoqin
    Ono, Yasuo
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2015, 21 (3-4) : 202 - 206