Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes

被引:127
|
作者
Yang, Yongfeng
Dokhale, Purushottam A.
Silverman, Robert W.
Shah, Kanai S.
McClish, Mickel A.
Farrell, Richard
Entine, Gerald
Cherry, Simon R.
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Radiat Monitoring Devices Inc, Watertown, MA 02172 USA
[3] Univ Calif Los Angeles, Dept Mol & Med Pharmacol, Los Angeles, CA 90095 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 09期
关键词
D O I
10.1088/0031-9155/51/9/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We explore dual-ended read out of LSO arrays with two position sensitive avalanche photodiodes (PSAPDs) as a high resolution, high efficiency depth-encoding detector for PET applications. Flood histograms, energy resolution and depth of interaction (DOI) resolution were measured for unpolished LSO arrays with individual crystal sizes of 1.0, 1.3 and 1.5 mm, and for a polished LSO array with 1.3 mm pixels. The thickness of the crystal arrays was 20 mm. Good flood histograms were obtained for all four arrays, and crystals in all four arrays can be clearly resolved. Although the amplitude of each PSAPD signal decreases as the interaction depth moves further from the PSAPD, the sum of the two PSAPD signals is essentially constant with irradiation depth for all four arrays. The energy resolutions were similar for all four arrays, ranging from 14.7% to 15.4%. A DOI resolution of 3-4 mm (including the width of the irradiation band which is similar to 2 mm) was obtained for all the unpolished arrays. The best DOI resolution was achieved with the unpolished 1mm array (average 3.5 mm). The DOI resolution for the 1.3 mm and 1.5 mm unpolished arrays was 3.7 and 4.0 mm respectively. For the polished array, the DOI resolution was only 16.5 mm. Summing the DOI profiles across all crystals for the 1 mm array only degraded the DOI resolution from 3.5 mm to 3.9 mm, indicating that it may not be necessary to calibrate the DOI response separately for each crystal within an array. The DOI response of individual crystals in the array confirms this finding. These results provide a detailed characterization of the DOI response of these PSAPD-based PET detectors which will be important in the design and calibration of a PET scanner making use of this detector approach.
引用
收藏
页码:2131 / 2142
页数:12
相关论文
共 50 条
  • [1] Investigation of position sensitive avalanche photodiodes for a new high resolution PET detector design
    Levin, CS
    Foudray, AMK
    Olcott, PD
    Habte, F
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2262 - 2266
  • [2] Investigation of position sensitive avalanche photodiodes for a new high-resolution PET detector design
    Levin, CS
    Foudray, AMK
    Olcott, PD
    Habte, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 805 - 810
  • [3] Influence of temperature and bias voltage on the performance of a high resolution PET detector built with position sensitive avalanche photodiodes
    Vandenbroucke, A.
    McLaughlin, T. J.
    Levin, C. S.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [4] Design of high resolution PET detectors using avalanche photodiodes
    Burr, Kent C.
    Ivan, Adrian
    Wang, Gin-Chung
    LeBlanc, James W.
    McClish, Mickel A.
    Farrell, Richard
    Shah, Kanai S.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2794 - 2798
  • [5] Avalanche photodiodes in scintillation detection for high resolution PET
    Kapusta, M
    Moszynski, M
    Balcerzyk, M
    Lesniewski, K
    Szawlowski, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 2029 - 2033
  • [6] Evaluation of position sensitive avalanche photodiodes for PET
    Burr, KC
    Ivan, A
    LeBlanc, J
    Zelakiewicz, S
    McDaniel, DL
    Kim, CL
    Ganin, A
    Shah, KS
    Grazioso, R
    Farrell, R
    Glodo, J
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 332 - 336
  • [7] AVALANCHE PHOTODIODES FOR HIGH-RESOLUTION PET IMAGING SYSTEMS
    Bugalho, R.
    Carrico, B.
    Ferreira, C. S.
    Ferreira, M.
    Moura, R.
    Ortigao, C.
    Pinheiro, J.
    Rodrigues, P.
    Silva, J. C.
    Trindade, A.
    Varela, J.
    BIODEVICES 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2009, : 31 - 38
  • [8] Resolution improvement in PET using detector depth of interaction information.
    Dahlbom, M
    MacDonald, LR
    Cherry, SR
    Eriksson, L
    Casey, ME
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 162 - 162
  • [9] Performance characterization of a novel thin position-sensitive avalanche photodiode-based detector for high resolution PET
    Zhang, Jin
    Foudray, Angela M. K.
    Olcott, Peter D.
    Levin, Craig S.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2478 - 2482
  • [10] Four-layer depth-of-interaction PET detector for high resolution PET using a multi-pixel S8550 avalanche photodiode
    Nishikido, Fumihiko
    Inadama, Naoko
    Oda, Ichiro
    Shibuya, Kengo
    Yoshida, Eiji
    Yamaya, Taiga
    Kitamura, Keishi
    Murayama, Hideo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 570 - 575