Investigation of position sensitive avalanche photodiodes for a new high-resolution PET detector design

被引:45
|
作者
Levin, CS [1 ]
Foudray, AMK
Olcott, PD
Habte, F
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
[2] Univ Calif San Diego, Dept Phys, La Jolla, CA 92037 USA
[3] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
avalanche photodiodes; photodetectors; positron emission tomography (PET); scintillation detectors;
D O I
10.1109/TNS.2004.830112
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We are developing a high-resolution PET detector design with a goal of nearly complete scintillation light collection in less than or equal to 1 mm width, greater than or equal to 20 mm effective thickness LSO crystals. The design uses position sensitive avalanche photodiodes in novel layered configurations that significantly improve the light collection aspect ratio. To reduce design complexity and dead area we are investigating the use of 1 mm thick sheets of LSO in addition to discrete crystal rods, and the use of PSAPDs which require only four readout channels per device. The raw spatial response of a 1 mm thick crystal sheet coupled to a PSAPD exhibits a compressed dynamic range compared to that observed with discrete crystals. Measurements with the proposed configurations using Na-22. irradiation achieved 10%-13% FWHM energy resolution at 511 keV and 2 ns coincidence time resolution. 1 mm width crystals with a saw cut surface finish an no inter-crystal reflector were well resolved in flood images.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [1] Investigation of position sensitive avalanche photodiodes for a new high resolution PET detector design
    Levin, CS
    Foudray, AMK
    Olcott, PD
    Habte, F
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2262 - 2266
  • [2] Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes
    Yang, Yongfeng
    Dokhale, Purushottam A.
    Silverman, Robert W.
    Shah, Kanai S.
    McClish, Mickel A.
    Farrell, Richard
    Entine, Gerald
    Cherry, Simon R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (09): : 2131 - 2142
  • [3] Influence of temperature and bias voltage on the performance of a high resolution PET detector built with position sensitive avalanche photodiodes
    Vandenbroucke, A.
    McLaughlin, T. J.
    Levin, C. S.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [4] AVALANCHE PHOTODIODES FOR HIGH-RESOLUTION PET IMAGING SYSTEMS
    Bugalho, R.
    Carrico, B.
    Ferreira, C. S.
    Ferreira, M.
    Moura, R.
    Ortigao, C.
    Pinheiro, J.
    Rodrigues, P.
    Silva, J. C.
    Trindade, A.
    Varela, J.
    BIODEVICES 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2009, : 31 - 38
  • [5] Evaluation of position sensitive avalanche photodiodes for PET
    Burr, KC
    Ivan, A
    LeBlanc, J
    Zelakiewicz, S
    McDaniel, DL
    Kim, CL
    Ganin, A
    Shah, KS
    Grazioso, R
    Farrell, R
    Glodo, J
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 332 - 336
  • [6] Design of high resolution PET detectors using avalanche photodiodes
    Burr, Kent C.
    Ivan, Adrian
    Wang, Gin-Chung
    LeBlanc, James W.
    McClish, Mickel A.
    Farrell, Richard
    Shah, Kanai S.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2794 - 2798
  • [7] HIGH-RESOLUTION POSITION-SENSITIVE DETECTOR
    GAO, RS
    ROBERT, WE
    SMITH, GJ
    SMITH, KA
    STEBBINGS, RF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (09): : 1954 - 1956
  • [8] Investigation of scintillation light multiplexing for PET detectors based on position sensitive avalanche photodiodes
    Habte, Frezghi
    Olcott, Peter D.
    Levin, Craig S.
    Foudray, Angela M. K.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2027 - 2030
  • [9] Avalanche photodiodes in scintillation detection for high resolution PET
    Kapusta, M
    Moszynski, M
    Balcerzyk, M
    Lesniewski, K
    Szawlowski, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 2029 - 2033
  • [10] A NEW DUAL CRYSTAL DEPTH SENSITIVE DETECTOR FOR HIGH-RESOLUTION PET CAMERAS
    LECOMTE, R
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 974 - 974