Determination of tissue optical properties from spatially resolved relative diffuse reflectance

被引:0
|
作者
Chen, YQ [1 ]
Lin, L [1 ]
Li, G [1 ]
Ye, WY [1 ]
Yu, QL [1 ]
机构
[1] Tianjin Univ, Coll Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
关键词
tissue optics; reflectance; Monte Carlo; neural network; principal component analysis;
D O I
10.1117/12.571446
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Noninvasive determination of mu(s)' and mu(a) is essential for clinical applications in medical diagnostics and therapeutics. Spatially resolved diffuse reflectance method is more advantageous than other techniques because of its simplicity and low-cost. The methods for solving the nonlinear inverse problem of estimates of mu(s)' and mu(a) from spatially resolved diffuse reflectance R-d(r) can be classified into the algorithms based on absolute or relative reflectance measurements in nature. Since absolute reflectance measurements are technically more difficult to perform than the relative one, study on the methods based on the relative reflectance has a more important meaning for real applications. Considering that there were several normalizations of R-d(r), in this paper we discussed the varieties of prediction rms errors of mu(s)' and mu(a) extracted from relative reflectance data of different normalization forms including R-d(r)/R-d(r)(max), r(2)(R-d(r)/R-d(r)(max)), ln(R-d(r)/R-d(r)(max)) and ln(r(2)(R-d(r)/R-d(r)(max))). Additionally, we compared the accuracies of mu(s)' and mu(a) determined from absolute reflectance data R-d(r) and ln(R-d(r)) with that from relative reflectance data to study the loss of accuracy due to normalization. Rather than the traditional neural network methods, we used a new method - PCA-NN trained with diffuse reflectance data from Monte Carlo simulations to derive mu(s)' and mu(a). All the PCA-NNs were trained and tested on the space with mu(s)' between 0. 1 and 2.0 mm(-1) and mu(a) between 0.01 and 0.1 mm(-1). The test results indicate that the rms errors in mu(s)' and mu(a) are 0.72% and 2.57% for R-d(r), 0.28% and 0.55% for ln(R-d(r)), 2.98% and 5.44% for R-d(r)/R-d(r)(max), 2.22% and 3.21% for ln(R-d(r)/R-d(r)(max)), 6.52% and 20.7% for r(2)(R-d(r)/R-d(r)(max)), and 2.22% and 3.21% for ln(r(2)(R-d(r)/R-d(r) max)), Suggesting that the normalization form ln(R-d(r)/R-d(r)(max)) would be the first choice for the estimates of As' and A. from relative reflectance data by PCA-NN. Although the loss of accuracy due to normalization is considerable, the preliminary results provide a guideline for relative reflectance measurements.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 50 条
  • [21] A DIFFUSION-THEORY MODEL OF SPATIALLY RESOLVED, STEADY-STATE DIFFUSE REFLECTANCE FOR THE NONINVASIVE DETERMINATION OF TISSUE OPTICAL-PROPERTIES INVIVO
    FARRELL, TJ
    PATTERSON, MS
    WILSON, B
    MEDICAL PHYSICS, 1992, 19 (04) : 879 - 888
  • [22] The determination of in vivo human tissue optical properties and absolute chromophore concentrations using spatially resolved steady-state diffuse reflectance spectroscopy
    Doornbos, RMP
    Lang, R
    Aalders, MC
    Cross, FW
    Sterenborg, HJCM
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (04): : 967 - 981
  • [23] Multivariate method for the determination of tissue optical properties from diffuse reflectance profiles
    Yeh, SJ
    Khalil, OS
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 : 456 - 464
  • [24] Determination of tissue optical properties from diffuse reflectance profiles by multivariate calibration
    Dam, JS
    Andersen, PE
    Dalgaard, T
    Fabricius, PE
    APPLIED OPTICS, 1998, 37 (04): : 772 - 778
  • [25] Determination of tissue optical properties by time-resolved reflectance
    Liu, XL
    Zhang, R
    Bao, HJ
    Zhong, JK
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 460 - 461
  • [26] Tissue optical properties from spatially resolved reflectance: calibration and in vivo application on rat kidney
    Gladytz, Thomas
    Hoppe, Alexander
    Cantow, Kathleen
    Flemming, Bert
    Pohlmann, Andreas
    Niendorf, Thoralf
    Seeliger, Erdmann
    Grosenick, Dirk
    DIFFUSE OPTICAL SPECTROSCOPY AND IMAGING VI, 2017, 10412
  • [27] Extraction of optical properties in the sub-diffuse regime by spatially resolved reflectance spectroscopy
    Naglic, Peter
    Cugmas, Blaz
    Pernus, Franjo
    Likar, Bostjan
    Burmen, Miran
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXVII, 2016, 9706
  • [28] Sensitivity of spatially resolved reflectance signals to coincident variations in tissue optical properties
    Arifler, Dizem
    APPLIED OPTICS, 2010, 49 (22) : 4310 - 4320
  • [29] Optical properties of phantoms and tissue measured in vivo from 0.9-1.3 mu m using spatially resolved diffuse reflectance
    Bruulsema, JT
    Hayward, JE
    Farrell, TJ
    Essenpreis, M
    Patterson, MS
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF, 1997, 2979 : 325 - 334
  • [30] Metamodeling approach for efficient estimation of optical properties of turbid media from spatially resolved diffuse reflectance measurements
    Watte, Rodrigo
    Nghia Nguyen Do Trong
    Aernouts, Ben
    Erkinbaev, Chyngyz
    De Baerdemaeker, Josse
    Nicolai, Bart
    Saeys, Wouter
    OPTICS EXPRESS, 2013, 21 (26): : 32630 - 32642