Fracture behavior of cantilever fixed dental prostheses fabricated from different zirconia generations

被引:3
|
作者
Schmidt, Michael B. [1 ]
Rosentritt, Martin [2 ]
Hahnel, Sebastian [1 ]
Wertz, Markus [1 ]
Hoelzig, Hieronymus [3 ]
Kloess, Gert [3 ]
Koenig, Andreas [1 ]
机构
[1] Univ Leipzig, Med Ctr, Dept Prosthet Dent & Dent Mat Sci, Leipzig, Germany
[2] Regensburg Univ, Dept Prosthet Dent, Med Ctr, Regensburg, Germany
[3] Univ Leipzig, Inst Mineral Crystallog & Mat Sci, D-04103 Leipzig, Germany
来源
QUINTESSENCE INTERNATIONAL | 2022年 / 53卷 / 05期
关键词
cantilever fixed dental prosthesis; fracture load; 3Y-TZP; 4Y-TZP; 5Y-TZP; zirconia; LOW-TEMPERATURE DEGRADATION; INCREASED TOOTH MOBILITY; ALVEOLAR BONE SUPPORT; MECHANICAL-PROPERTIES; Y-TZP; PHASE-TRANSFORMATION; IN-VITRO; PART II; STRENGTH; RESISTANCE;
D O I
10.3290/j.qi.b2793243
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this study was to compare the fracture behavior of cantilever fixed dental prostheses (FDPs) fabricated from 3Y-TZP, 4Y-TZP, or 5Y-TZP zirconia. Method and materials: Posterior cantilever FDPs (three groups, each n = 16) were digitally designed and milled. After sintering, eight specimens/group were stored in demineralized water for 72 hours; eight specimens/group were subjected to accelerated aging using chewing simulation with thermal cycling (1,200,000 x 50 N; 2 x 3,000 x 5 degrees C/55 degrees C; H2O2 minutes/cycle) and finally stored in demineralized water for 24 hours. The cantilever FDPs were then statically loaded to failure to determine fracture load. Phase transformation towards the monoclinic phase was controlled with x-ray diffractometry. Results: One failure was identified after accelerated aging in the 5Y-TZP group. Fracture load decreased with increasing yttria content and decreasing bending strength. Accelerated aging using chewing simulation with thermal cycling caused a significant decline in fracture load. All FDPs failed in the area of the prepared tooth and in proximity to the cantilever, where the largest bending moment occurred. The yttria content had no influence on the type of fracture. With increasing yttria content, the relation between deformation and fracture load decreased only slightly. On the surface of FDPs that had been subjected to chewing simulation, no phase transformation towards the monoclinic phase (eg, low temperature degradation) was detected. Conclusion: Within the limitations of a laboratory study, the data indicate that 3Y-, 4Y-, and 5Y-TZP may be employed as material for the fabrication of permanent posterior cantilever FDPs. However, more data are necessary to finally advocate the application of 5-Y-TZP.
引用
收藏
页码:414 / 422
页数:9
相关论文
共 50 条
  • [41] Precision of fit: zirconia three-unit fixed dental prostheses
    Beuer, Florian
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL ORAL INVESTIGATIONS, 2009, 13 (03) : 343 - 349
  • [42] Precision of fit: zirconia three-unit fixed dental prostheses
    Florian Beuer
    Michael Naumann
    Wolfgang Gernet
    John A. Sorensen
    Clinical Oral Investigations, 2009, 13
  • [43] Biomechanical behavior of posterior metal-free cantilever fixed dental prostheses: effect of material and retainer design
    Ammar T. Kasem
    Abdallah Ahmed Elsherbiny
    Manal Abo-Madina
    João Paulo M. Tribst
    Walid Al-Zordk
    Clinical Oral Investigations, 2023, 27 : 2109 - 2123
  • [44] Biomechanical behavior of posterior metal-free cantilever fixed dental prostheses: effect of material and retainer design
    Kasem, Ammar T. T.
    Elsherbiny, Abdallah Ahmed
    Abo-Madina, Manal
    Tribst, Joao Paulo M.
    Al-Zordk, Walid
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (05) : 2109 - 2123
  • [45] Effect of implant type on the stability of cantilever fixed dental prostheses: An in vitro study
    Rohr, Nadja
    Karakas-Stupar, Irina
    Karlin, Sabrina
    Zitzmann, Nicola U.
    Zaugg, Lucia K.
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (04) : 419 - 426
  • [46] Anterior Cantilever Resin-Bonded Fixed Dental Prostheses: A Review of the Literature
    Mourshed, Bilal
    Samran, Abdulaziz
    Alfagih, Amal
    Samran, Ahalm
    Abdulrab, Saleem
    Kern, Matthias
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (03): : 266 - 275
  • [47] Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques
    Nesse, Harald
    Ulstein, Dina Mari Akeryik
    Vaage, Malene Myhre
    Oilo, Marit
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (05): : 686 - 692
  • [48] Stereolithography-fabricated zirconia dental prostheses: concerns based on clinical requirements
    Li, Hezhen
    Song, Lu
    Sun, Jialin
    Ma, Jing
    Shen, Zhijian
    ADVANCES IN APPLIED CERAMICS, 2020, 119 (5-6) : 236 - 243
  • [49] No-Prep Zirconia Cantilever Resin-Bonded Fixed Dental Prostheses: A Noninvasive, Simple Approach to Replacing a Single Missing Tooth
    Mainjot, Amelie Karine Jacques
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2025, 37 (01) : 68 - 84
  • [50] Ten-year outcome of zirconia ceramic cantilever resin-bonded fixed dental prostheses and the influence of the reasons for missing incisors
    Kern, Matthias
    Passia, Nicole
    Sasse, Martin
    Yazigi, Christine
    JOURNAL OF DENTISTRY, 2017, 65 : 51 - 55