Fracture behavior of cantilever fixed dental prostheses fabricated from different zirconia generations

被引:3
|
作者
Schmidt, Michael B. [1 ]
Rosentritt, Martin [2 ]
Hahnel, Sebastian [1 ]
Wertz, Markus [1 ]
Hoelzig, Hieronymus [3 ]
Kloess, Gert [3 ]
Koenig, Andreas [1 ]
机构
[1] Univ Leipzig, Med Ctr, Dept Prosthet Dent & Dent Mat Sci, Leipzig, Germany
[2] Regensburg Univ, Dept Prosthet Dent, Med Ctr, Regensburg, Germany
[3] Univ Leipzig, Inst Mineral Crystallog & Mat Sci, D-04103 Leipzig, Germany
来源
QUINTESSENCE INTERNATIONAL | 2022年 / 53卷 / 05期
关键词
cantilever fixed dental prosthesis; fracture load; 3Y-TZP; 4Y-TZP; 5Y-TZP; zirconia; LOW-TEMPERATURE DEGRADATION; INCREASED TOOTH MOBILITY; ALVEOLAR BONE SUPPORT; MECHANICAL-PROPERTIES; Y-TZP; PHASE-TRANSFORMATION; IN-VITRO; PART II; STRENGTH; RESISTANCE;
D O I
10.3290/j.qi.b2793243
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this study was to compare the fracture behavior of cantilever fixed dental prostheses (FDPs) fabricated from 3Y-TZP, 4Y-TZP, or 5Y-TZP zirconia. Method and materials: Posterior cantilever FDPs (three groups, each n = 16) were digitally designed and milled. After sintering, eight specimens/group were stored in demineralized water for 72 hours; eight specimens/group were subjected to accelerated aging using chewing simulation with thermal cycling (1,200,000 x 50 N; 2 x 3,000 x 5 degrees C/55 degrees C; H2O2 minutes/cycle) and finally stored in demineralized water for 24 hours. The cantilever FDPs were then statically loaded to failure to determine fracture load. Phase transformation towards the monoclinic phase was controlled with x-ray diffractometry. Results: One failure was identified after accelerated aging in the 5Y-TZP group. Fracture load decreased with increasing yttria content and decreasing bending strength. Accelerated aging using chewing simulation with thermal cycling caused a significant decline in fracture load. All FDPs failed in the area of the prepared tooth and in proximity to the cantilever, where the largest bending moment occurred. The yttria content had no influence on the type of fracture. With increasing yttria content, the relation between deformation and fracture load decreased only slightly. On the surface of FDPs that had been subjected to chewing simulation, no phase transformation towards the monoclinic phase (eg, low temperature degradation) was detected. Conclusion: Within the limitations of a laboratory study, the data indicate that 3Y-, 4Y-, and 5Y-TZP may be employed as material for the fabrication of permanent posterior cantilever FDPs. However, more data are necessary to finally advocate the application of 5-Y-TZP.
引用
收藏
页码:414 / 422
页数:9
相关论文
共 50 条
  • [31] Survival and complications of implant-supported cantilever fixed dental prostheses with zirconia and metal frameworks: A retrospective cohort study
    Horsch, Laura
    Kronsteiner, Dorothea
    Rammelsberg, Peter
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (05) : 621 - 629
  • [32] Effect of gingival ceramic veneer thickness on the fracture strength of zirconia-based fixed dental prostheses
    Gabbert, Olaf
    Ohlmann, Brigitte
    Schmitter, Marc
    Farhan, Daniel
    Becker, Falk
    Rammelsberg, Peter
    AMERICAN JOURNAL OF DENTISTRY, 2010, 23 (03): : 147 - 151
  • [33] Effect of veneering materials on fracture loads of implant-supported zirconia molar fixed dental prostheses
    Kondo, Tomohide
    Komine, Futoshi
    Honda, Junichi
    Takata, Hiroki
    Moriya, Yuta
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (02) : 140 - 144
  • [34] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Schoenberger, Joana
    Erdelt, Kurt-Juergen
    Baeumer, Daniel
    Beuer, Florian
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2629 - 2635
  • [35] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Joana Schönberger
    Kurt-Jürgen Erdelt
    Daniel Bäumer
    Florian Beuer
    Clinical Oral Investigations, 2017, 21 : 2629 - 2635
  • [36] Effect of firing procedures and layering thickness of porcelain on internal adaptation of zirconia cantilever resin-bonded fixed dental prostheses
    Kitani, Jin
    Komine, Futoshi
    Kusaba, Kosuke
    Nakase, Daishi
    Ito, Keigo
    Matsumura, Hideo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 333 - 338
  • [37] Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses
    Subsomboon, Chonticha
    Urapepon, Somchai
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (04): : 171 - 178
  • [38] Fit of High-Translucency Zirconia Fixed Dental Prostheses Using Two Different Intraoral Scanners
    Aktas, Guliz
    Guncu, Mustafa Baris
    Amini, Hanyeh
    Turkyilmaz, Ilser
    Gavras, Joanna Nicolette
    Zengin, Hatice Yagmur
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (04) : 498 - 500
  • [39] Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses
    Kohorst, P.
    Brinkmann, H.
    Dittmer, M. P.
    Borchers, L.
    Stiesch, M.
    JOURNAL OF ORAL REHABILITATION, 2010, 37 (04) : 283 - 291
  • [40] Clinical evaluation of monolithic zirconia multiunit posterior fixed dental prostheses
    Lestan, Nina Grguras
    Ozcan, Mutlu
    Kocjan, Andraz
    Oblak, Cedomir
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (06): : 1258 - 1264