Fracture behavior of cantilever fixed dental prostheses fabricated from different zirconia generations

被引:3
|
作者
Schmidt, Michael B. [1 ]
Rosentritt, Martin [2 ]
Hahnel, Sebastian [1 ]
Wertz, Markus [1 ]
Hoelzig, Hieronymus [3 ]
Kloess, Gert [3 ]
Koenig, Andreas [1 ]
机构
[1] Univ Leipzig, Med Ctr, Dept Prosthet Dent & Dent Mat Sci, Leipzig, Germany
[2] Regensburg Univ, Dept Prosthet Dent, Med Ctr, Regensburg, Germany
[3] Univ Leipzig, Inst Mineral Crystallog & Mat Sci, D-04103 Leipzig, Germany
来源
QUINTESSENCE INTERNATIONAL | 2022年 / 53卷 / 05期
关键词
cantilever fixed dental prosthesis; fracture load; 3Y-TZP; 4Y-TZP; 5Y-TZP; zirconia; LOW-TEMPERATURE DEGRADATION; INCREASED TOOTH MOBILITY; ALVEOLAR BONE SUPPORT; MECHANICAL-PROPERTIES; Y-TZP; PHASE-TRANSFORMATION; IN-VITRO; PART II; STRENGTH; RESISTANCE;
D O I
10.3290/j.qi.b2793243
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this study was to compare the fracture behavior of cantilever fixed dental prostheses (FDPs) fabricated from 3Y-TZP, 4Y-TZP, or 5Y-TZP zirconia. Method and materials: Posterior cantilever FDPs (three groups, each n = 16) were digitally designed and milled. After sintering, eight specimens/group were stored in demineralized water for 72 hours; eight specimens/group were subjected to accelerated aging using chewing simulation with thermal cycling (1,200,000 x 50 N; 2 x 3,000 x 5 degrees C/55 degrees C; H2O2 minutes/cycle) and finally stored in demineralized water for 24 hours. The cantilever FDPs were then statically loaded to failure to determine fracture load. Phase transformation towards the monoclinic phase was controlled with x-ray diffractometry. Results: One failure was identified after accelerated aging in the 5Y-TZP group. Fracture load decreased with increasing yttria content and decreasing bending strength. Accelerated aging using chewing simulation with thermal cycling caused a significant decline in fracture load. All FDPs failed in the area of the prepared tooth and in proximity to the cantilever, where the largest bending moment occurred. The yttria content had no influence on the type of fracture. With increasing yttria content, the relation between deformation and fracture load decreased only slightly. On the surface of FDPs that had been subjected to chewing simulation, no phase transformation towards the monoclinic phase (eg, low temperature degradation) was detected. Conclusion: Within the limitations of a laboratory study, the data indicate that 3Y-, 4Y-, and 5Y-TZP may be employed as material for the fabrication of permanent posterior cantilever FDPs. However, more data are necessary to finally advocate the application of 5-Y-TZP.
引用
收藏
页码:414 / 422
页数:9
相关论文
共 50 条
  • [1] Fracture behaviour of zirconia ceramic cantilever fixed dental prostheses in vitro
    Gabbert, Olaf
    Ohlmann, Brigitte
    Schmitter, Marc
    Gilde, Herbert
    Ruef, Thomas
    Rammelsberg, Peter
    ACTA ODONTOLOGICA SCANDINAVICA, 2008, 66 (04) : 200 - 206
  • [2] Fracture Resistance of Posterior Tooth-Supported Cantilever Fixed Dental Prostheses of Different Zirconia Generations and Framework Thicknesses: An In Vitro Study
    Klotz, Anna-Luisa
    Halfmann, Janina
    Rues, Stefan
    Boemicke, Wolfgang
    Rammelsberg, Peter
    Zenthoefer, Andreas
    MATERIALS, 2024, 17 (01)
  • [3] Influence of Fabrication Techniques and Artificial Aging on the Fracture Resistance of Different Cantilever Zirconia Fixed Dental Prostheses
    Ghazy, Mohamed H.
    Madina, Manal M. Abo
    Aboushelib, Moustafa N.
    JOURNAL OF ADHESIVE DENTISTRY, 2012, 14 (02): : 161 - 166
  • [4] Stability of Cantilever Fixed Dental Prostheses on Zirconia Implants
    Rohr, Nadja
    Nuesch, Reto
    Greune, Rebecca
    Mainetti, Gino
    Karlin, Sabrina
    Zaugg, Lucia K.
    Zitzmann, Nicola U.
    MATERIALS, 2022, 15 (10)
  • [5] Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses
    Lopez-Suarez, Carlos
    Rodriguez, Veronica
    Pelaez, Jesus
    Agustin-Panadero, Ruben
    Suarez, Maria J.
    DENTAL MATERIALS JOURNAL, 2017, 36 (06) : 816 - 821
  • [6] Fracture Behavior of Minimally Invasive, Posterior, and Fixed Dental Prostheses Manufactured from Monolithic Zirconia
    Boemicke, Wolfgang
    Rues, Stefan
    Hlavacek, Verena
    Rammelsberg, Peter
    Schmitter, Marc
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2016, 28 (06) : 367 - 381
  • [7] Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts
    Beuer, Florian
    Korczynski, Natalie
    Rezac, Antonia
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2010, 2 : 5 - 11
  • [8] Durability of cantilever inlay-retained fixed dental prosthesis fabricated from multilayered zirconia ceramics with different designs
    Al-Dwairi, Ziad N.
    Al-Aghbari, Latifah
    Husain, Nadin Al-Haj
    Ozcan, Mutlu
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 137
  • [9] Effect of veneering technique on the fracture resistance of zirconia fixed dental prostheses
    Chaar, M. S.
    Witkowski, S.
    Strub, J. R.
    Att, W.
    JOURNAL OF ORAL REHABILITATION, 2013, 40 (01) : 51 - 59
  • [10] Wear behavior between zirconia and titanium as an antagonist on fixed dental prostheses
    Kanbara, Tsunemichi
    Sekine, Hideshi
    Homma, Shinya
    Yajima, Yasutomo
    Yoshinari, Masao
    BIOMEDICAL MATERIALS, 2014, 9 (02)