Effect of Power Frequency Harmonics in Conducted Emission Measurement

被引:0
|
作者
Mahesh, G. [1 ]
Subbarao, B. [1 ]
Karunakaran, S. [1 ]
机构
[1] SAMEER Ctr Electromagnet, Madras 600113, Tamil Nadu, India
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conducted Emission (CE) measurement for AC operated equipment is carried out to quantity the amount of noise / interference generated by Equipment Under Test (EUT) and sent back to power supply input terminal through power cable. The increased use of non linear devices has resulted in increased 'power harmonics' and thus degradation of power quality. The interference generated by, the EUT will not only depend on its internal source (electronics) but also will depend on the input AC mains power quality. The presence of voltage harmonics at line impedance stabilization network (LISN) output significantly affects the conducted emission generated by EUT. This paper establishes the effect of voltage harmonics on CE measurement with experimental results and data. It also stresses the need for specification of maximum allowable voltage Total Harmonic Distortion (THD) in electromagnetic compatibility (EMC) standards.
引用
下载
收藏
页码:273 / 277
页数:5
相关论文
共 50 条
  • [31] Research on Power Measurement in Harmonics Disturbance Circumstances
    Xu, Yu
    MEMS, NANO AND SMART SYSTEMS, PTS 1-6, 2012, 403-408 : 3253 - 3257
  • [32] Measurement of Harmonics in the Finnish Power Grid.
    Kuronen, Pertti
    Lahtinen, Matti
    Sahko, 1979, 52 (5-6): : 163 - 168
  • [33] Simulation Study on Conducted Emission of Power Conversion System
    Lin, Guangjin
    Cai, Qiang-Ming
    Deng, Shilu
    Cao, Xin
    Guo, Feng
    Fan, Jun
    2023 ASIA-PACIFIC MICROWAVE CONFERENCE, APMC, 2023, : 467 - 469
  • [34] Undesired Emission from Coupled-Resonant Wireless Power Transfer Antenna for Fundamental and Harmonics Frequency
    Hirayama, Hiroshi
    Yamada, Hiroyuki
    Kikuma, Nobuvoshi
    Sakakibara, Kunio
    2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, TOKYO (EMC'14/TOKYO), 2014, : 438 - 441
  • [35] EFFECT OF AURAL HARMONICS ON FREQUENCY DISCRIMINATION
    HENNING, GB
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1965, 37 (06): : 1144 - &
  • [36] Effect of power line interference on microphone calibration measurements made at or near harmonics of the power line frequency
    Wagner, Randall P.
    Nedzelnitsky, Victor
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2007, 112 (02) : 107 - 114
  • [37] The Effect of The Grounding Condition of Line Impedance Stabilization Network on The Measurement Validity of Conducted Emission Parameter
    Ananda, Wisnu
    Cahyadi, Seto Ayom
    Inayaturohman, Irwan
    Hamdani, Deny
    2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 498 - 502
  • [38] Modelling and Measurement of High Switching Frequency Conducted EMI
    Grobler, I.
    Gitau, M. N.
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 1031 - 1036
  • [39] The effect of impedance mismatch on the conducted EMI emission
    Thammasiriroj, W
    Ruayariyasub, S
    Khan-ngern, W
    Nitta, S
    ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS, CEEM'2003, PROCEEDINGS, 2003, : 346 - 349
  • [40] Normalized estimation of fundamental frequency and measurement of harmonics/interharmonics
    Chu Z.
    Ding M.
    Du S.
    Dong X.
    Chu, Z. (zbchu@hfut.edu.cn), 1600, South China University of Technology (11): : 10 - 17