Effect of Power Frequency Harmonics in Conducted Emission Measurement

被引:0
|
作者
Mahesh, G. [1 ]
Subbarao, B. [1 ]
Karunakaran, S. [1 ]
机构
[1] SAMEER Ctr Electromagnet, Madras 600113, Tamil Nadu, India
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conducted Emission (CE) measurement for AC operated equipment is carried out to quantity the amount of noise / interference generated by Equipment Under Test (EUT) and sent back to power supply input terminal through power cable. The increased use of non linear devices has resulted in increased 'power harmonics' and thus degradation of power quality. The interference generated by, the EUT will not only depend on its internal source (electronics) but also will depend on the input AC mains power quality. The presence of voltage harmonics at line impedance stabilization network (LISN) output significantly affects the conducted emission generated by EUT. This paper establishes the effect of voltage harmonics on CE measurement with experimental results and data. It also stresses the need for specification of maximum allowable voltage Total Harmonic Distortion (THD) in electromagnetic compatibility (EMC) standards.
引用
下载
收藏
页码:273 / 277
页数:5
相关论文
共 50 条
  • [21] Influence of harmonics on power energy measurement
    Luo, Yaqiao
    Hu, Chong
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2009, 29 (05): : 130 - 132
  • [22] Effect of quality of power supply voltage on conducted emission in compact fluorescent lamps
    Brodecki, Dariusz
    PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (03): : 18 - 21
  • [23] Precision measurement of power harmonics and flicker
    Budovsky, I
    Hammond, G
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (02) : 483 - 487
  • [24] Frequency Measurement with High Accuracy and Method for Harmonics Identification in Polluted Distribution Power Networks
    Chanedeau, Gwladys
    Gaubert, Jean-Paul
    Rambault, Laurent
    Tissier, Jean-Francois
    2012 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2012, : 474 - 479
  • [25] Estimation of Deviation of Conducted Emission Measurement without LISN
    Li, Kang-Rong
    See, Kye-Yak
    2016 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2016, : 946 - 949
  • [26] Effect of harmonics and high-frequency on OLEV system in distribution power system
    Kim, J.-C. (jckim@ssu.ac.kr), 1600, Korean Institute of Electrical Engineers (63):
  • [27] Current Probes for Differential Mode Conducted Emission Measurement
    Knight, D. A.
    Marshall, R. C.
    2017 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - EMC EUROPE, 2017,
  • [28] Impact Analysis of Conducted Emission Measurement Without LISN
    Li, Kang-Rong
    See, Kye-Yak
    Bandara, Rathnayaka Mudiyanselage Sooriya
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2016, 58 (03) : 776 - 783
  • [29] Conducted emission measurement of a cell phone processor module
    Wan, Fayu
    Ge, Junxiang
    Qu, Mengxiang
    Progress In Electromagnetics Research C, 2013, 42 : 191 - 203
  • [30] FREQUENCY TRACKING IN POWER NETWORKS IN THE PRESENCE OF HARMONICS
    BEGOVIC, MM
    DJURIC, PM
    DUNLAP, S
    PHADKE, AG
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (02) : 480 - 486