A Feasibility Study of Position-Sensitive Silicon Photomultiplier for Application in Scintillating Fiber Tracker

被引:0
|
作者
Peng, Yu [1 ]
Zhao, Tianqi [1 ]
Dai, Lei [1 ]
Xie, Yuguang [2 ]
Liang, Kun [1 ]
Yang, Ru [1 ]
Han, Dejun [1 ]
机构
[1] Beijing Normal Univ, Coll Nucl Sci & Technol, Beijing 100875, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Scintillating fiber tracker (SciFi Tracker) is a very important tracking detection mechanism in high energy physics experiments. The current SciFi tracking detector consists of staggered layers of scintillating fibers that are read out by one dimensional (1-D) pixel type silicon photomultiplier (SiPM) array, which shows such disadvantages as the large number of read-out channels and limited position resolution due to its pixel size. In order to overcome these drawbacks in SciFi Tracker, a two-dimensional (2-D) tetra-lateral position sensitive (PS) SiPM is proposed in this work to replace the 1-D pixel type SiPMs array, so that the read- out electronics can be greatly reduced while retaining a good position resolution.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Amorphous silicon position-sensitive detector
    Mochiki, Koh-ichi
    Hasegawa, Ken-ichi
    Namatame, Shuji
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 640 - 644
  • [42] EPITAXIAL SILICON POSITION-SENSITIVE DETECTORS
    SHIRAISHI, F
    KIM, C
    KIM, H
    KIKUCHI, K
    HUSIMI, K
    OHKAWA, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 554 - 557
  • [43] Two-dimensional neutron detector based on a position-sensitive photomultiplier
    Kurz, R.
    Reinartz, R.
    Widdau, S.
    Schelten, J.
    Scholz, A.
    Schaefer, W.
    Nuclear instruments and methods in physics research, 1988, 273 (01): : 273 - 282
  • [44] High-position-resolution neutron detector using a position-sensitive photomultiplier tube
    Clergeau, JF
    Guérard, B
    Buffet, JC
    Van Esch, P
    ADVANCES IN NEUTRON SCATTERING INSTRUMENTATION, 2002, 4785 : 254 - 261
  • [45] HIGH-RESOLUTION SCINTILLATION HODOSCOPE USING A POSITION-SENSITIVE PHOTOMULTIPLIER
    DITTA, J
    SILLOU, D
    MICHALOWICZ, A
    AZAIEZ, H
    KURODA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 220 (2-3): : 343 - 348
  • [46] RADIONUCLIDE MAPPING USING A POSITION-SENSITIVE PHOTOMULTIPLIER TUBE AND A GERMANIUM DETECTOR
    DEWARAJA, YK
    HE, Z
    FLEMING, RF
    WEHE, DK
    FLEMING, RH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 649 - 652
  • [47] TWO-DIMENSIONAL NEUTRON DETECTOR BASED ON A POSITION-SENSITIVE PHOTOMULTIPLIER
    KURZ, R
    REINARTZ, R
    WIDDAU, S
    SCHELTEN, J
    SCHOLZ, A
    SCHAFER, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (01): : 273 - 282
  • [48] One-dimensional position-sensitive detector for alpha particles using an outer-layer scintillating fiber
    Toyama, Sho
    Daiki, Miura
    Miwa, Misako
    Matsuyama, Shigeo
    RADIATION MEASUREMENTS, 2023, 169
  • [49] A study of silicon photomultiplier sensor prototypes for readout of a scintillating fiber lead sheet barrel calorimeter
    Zorn, Carl J.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2099 - 2104
  • [50] New Distortion Correction Algorithm for Two-Dimensional Tetra-Lateral Position-Sensitive Silicon Photomultiplier
    Zhao, Tianqi
    Li, Baicheng
    Li, Chenhui
    Wang, Ruiheng
    Miao, Quanlong
    Liang, Kun
    Yang, Ru
    Han, Dejun
    IEEE ELECTRON DEVICE LETTERS, 2017, 38 (02) : 228 - 231