Sensitivity and Specificity of Serum and Synovial Fluid Markers in Diagnosis of Infection in Head-Neck Taper Corrosion of Metal-On-Polyethylene Total Hip Arthroplasty

被引:8
|
作者
Kwon, Young-Min [1 ]
Mahajan, John [1 ]
Tirumala, Venkatsaiakhil [1 ]
Oganesyan, Ruben [1 ]
Yeo, Ingwon [1 ]
Klemt, Christian [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Bioengn Lab, 55 Fruit St,Yawkey Suite 3B, Boston, MA 02114 USA
来源
JOURNAL OF ARTHROPLASTY | 2020年 / 35卷 / 12期
关键词
adverse local tissue reaction; periprosthetic joint infection; head-neck taper corrosion; cobalt and chromium metal ion level; metal-on-polyethylene total hip; arthroplasty; LOCAL TISSUE-REACTIONS; JUNCTION; OUTCOMES; UTILITY; STEM;
D O I
10.1016/j.arth.2020.06.058
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The accurate diagnosis of periprosthetic joint infection (PJI) in the setting of adverse local tissue reactions in patients with metal-on-polyethylene (MoP) total hip arthroplasty (THA) secondary to head-neck taper junction corrosion is challenging as it frequently has the appearance of purulence. The aim of this study is to evaluate the utility of erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and synovial fluid markers in diagnosing PJI in failed MoP THA due to head-neck taper corrosion. Methods: A total of 89 consecutive patients with MoP THA with head-neck taper corrosion in 2 groups was evaluated: (1) infection group (n = 11) and (2) noninfection group (n = 78). All patients had highly crossed polyethylene with cobalt chromium femoral heads and had preoperative synovial fluid aspiration. In addition, serum cobalt and chromium levels were analyzed. Results: The optimal cutoff value for synovial white blood cell was 2144 with 93% sensitivity and 84% specificity. Neutrophil count optimal cutoff value was 82% with 93% sensitivity and 82% specificity. Receiver operating characteristic analysis of ESR and CRP determined optimal cutoff at 57 mm/h and 35 mg/L with 57% sensitivity and 94% specificity and 93% sensitivity and 76% specificity, respectively. There were no significant differences in metal ion levels between the infected and noninfected groups. Conclusion: The results of this study suggest that ESR and CRP are useful in excluding PJI, whereas both synovial white blood cell count and neutrophil percentage in hip aspirate are useful markers for diagnosing infection in MoP THA patients with head-neck taper corrosion associated adverse local tissue reaction. (C) 2020 Elsevier Inc. All rights reserved.
引用
下载
收藏
页码:3737 / 3742
页数:6
相关论文
共 49 条
  • [1] Sensitivity and Specificity of Metal Ion Level in Predicting Adverse Local Tissue Reactions Due to Head-Neck Taper Corrosion in Primary Metal-on-Polyethylene Total Hip Arthroplasty
    Kwon, Young-Min
    MacAuliffe, John
    Arauz, Paul G.
    Peng, Yun
    JOURNAL OF ARTHROPLASTY, 2018, 33 (09): : 3025 - 3029
  • [2] Risk Factors Associated With Early Complications of Revision Surgery for Head-Neck Taper Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty
    Kwon, Young-Min
    Rossi, Daniel
    MacAuliffe, John
    Peng, Yun
    Arauz, Paul
    JOURNAL OF ARTHROPLASTY, 2018, 33 (10): : 3231 - 3237
  • [3] The Fate of Elevated Metal Ion Levels After Revision Surgery for Head-Neck Taper Corrosion in Patients With Metal-on-Polyethylene Total Hip Arthroplasty
    Kwon, Young-Min
    MacAuliffe, John
    Peng, Yun
    Arauz, Paul
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08): : 2631 - 2635
  • [4] Head-Neck Taper Corrosion in Hip Arthroplasty
    Hussenbocus, S.
    Kosuge, D.
    Solomon, L. B.
    Howie, D. W.
    Oskouei, R. H.
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [5] Head-Neck Taper Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty: Risk Factors, Clinical Evaluation, and Treatment of Adverse Local Tissue Reactions
    Fitz, David
    Klemt, Christian
    Chen, Wenhao
    Xiong, Liang
    Yeo, Ingwon
    Kwon, Young-Min
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (22) : 907 - 913
  • [6] Radiographic Risk Factors Associated With Adverse Local Tissue Reaction in Head-Neck Taper Corrosion of Primary Metal-on-Polyethylene Total Hip Arthroplasty
    Kwon, Young-Min
    An, Shuai
    Yeo, Ingwon
    Tirumala, Venkatsaiakhil
    Chen, Wenhao
    Klemt, Christian
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (08) : 353 - 360
  • [7] Pseudotumor and deep venous thrombosis due to crevice corrosion of the head-neck junction in metal-on-polyethylene total hip arthroplasty
    Watanabe, Hiroshi
    Takahashi, Kenji
    Takenouchi, Kenji
    Sato, Akiko
    Kawaji, Hidemi
    Nakamura, Hiroshi
    Takai, Shinro
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (06) : 1142 - 1147
  • [8] Head-neck taper corrosion following total hip arthroplasty with Stryker Meridian stem
    Patel, Sonika
    Talmo, Carl T.
    Nandi, Sumon
    HIP INTERNATIONAL, 2016, 26 (06) : E49 - E51
  • [9] Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties
    Triantafyllopoulos, Georgios K.
    Elpers, Marcella E.
    Burket, Jayme C.
    Esposito, Christina I.
    Padgett, Douglas E.
    Wright, Timothy M.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (02) : 330 - 338
  • [10] Corrosion of the Head-neck Junction After Total Hip Arthroplasty
    Jennings, Jason M.
    Dennis, Douglas A.
    Yang, Charlie C.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2016, 24 (06) : 349 - 356