Ductility of Concrete Members Reinforced with Welded Wire Reinforcement (WWR)

被引:5
|
作者
Shwani, Mohamed [1 ]
Tawadrous, Raed [2 ]
Maguire, Marc [3 ]
机构
[1] Amer Univ Iraq, Sulaimani Kirkuk Main Rd, Sulaimani, Krg, Iraq
[2] EConstruct Florida, 3452 Lake Lynda Dr Suite 350, Orlando, FL 32817 USA
[3] Utah State Univ, Dept Civil & Environm Engn, Logan, UT 84322 USA
关键词
Welded wire reinforcement; Ductility; Strain localization; Failure mode; Reinforced concrete; SLABS;
D O I
10.1016/j.engstruct.2019.04.081
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Past research studies have been conducted on the ductility of concrete members reinforced with welded wire reinforcement (WWR) and determined a new phenomenon called strain localization reduces member ductility due to superior bond between WWR and concrete. Such studies have concluded that strain localization adversely affects the ductility of members reinforced with WWR and it is unsafe to use WWR as tension reinforcement. In this study, 50 simply-supported, concrete slabs with a representative slab width of 2 ft (610 mm), thickness of 7 in. (180 nun), and total length of 21 ft (6.4 m) were tested to further examine the strain localization phenomenon on global deformations. Two major parameters were investigated, cross-weld spacing and wire diameter. The impact of these two parameters on strength, ductility, and mode of failure of concrete members reinforced with WWR was also studied. Moment curvature analysis was used to estimate inelastic deflections and ductility to investigate the effect of the reinforcement total elongation at failure of the wire material on the overall member ductility. It was observed that members reinforced with WWR with cross-weld spacing of 14 in. (355 mm) or more had similar ductility as members reinforced with loose wires (without cross-weld). Members reinforced with WWR with closely spaced cross-weld (i.e., 3 or 7 in. (75 or 180 mm)) showed erratic and often less ductility, however, the wire itself was shown to have low ductility. Failure of members reinforced with WWR provided sufficient warning prior to failure as evidenced by the ductility ratios in excess of 2.5. Additionally, a moment-curvature analysis based parametric study showed that an acceptable level of ductility can be achieved with a minimum total elongation of wire reinforcement of 3% at failure.
引用
收藏
页码:711 / 723
页数:13
相关论文
共 50 条
  • [41] Estimation of Minimum Torsional Reinforcement of Reinforced Concrete and Steel Fiber-Reinforced Concrete Members
    Ju, Hyunjin
    Han, Sun-Jin
    Zhang, Dichuan
    Kim, Jong
    Wu, Wei
    Kim, Kang Su
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2019, 2019
  • [42] ULTIMATE STRENGTH AND DUCTILITY OF REINFORCED CONCRETE COLUMNS WITH CONFINING REINFORCEMENT.
    Hirasawa, Ikuo
    Ito, Mitsuaki
    Chubu Daigaku Kogakubu kiyo, 1987, 23 : 69 - 78
  • [43] Flexural behavior of concrete beams with welded wire fabric as shear reinforcement
    Lin, CH
    Perng, SM
    ACI STRUCTURAL JOURNAL, 1998, 95 (05) : 540 - 546
  • [44] Longitudinal Reinforcement Limits for Fiber-Reinforced Polymer Reinforced Concrete Members
    Karim, Hogr
    Sheikh, M. Neaz
    Hadi, Muhammad N. S.
    ACI STRUCTURAL JOURNAL, 2017, 114 (03) : 687 - 696
  • [45] Shear Strength of Reinforced Concrete Members without Transverse Reinforcement
    Marti, Peter
    Beck, Alexander
    BETON- UND STAHLBETONBAU, 2016, 111 (11) : 716 - 727
  • [46] Shear database for reinforced concrete members without shear reinforcement
    Reineck, KH
    Kuchma, DA
    Kim, KS
    Marx, S
    ACI STRUCTURAL JOURNAL, 2003, 100 (02) : 240 - 249
  • [47] Effect of reinforcement ratio on concrete members reinforced with FRP bars
    Benmokrane, B
    Theriault, M
    Masmoudi, R
    Rizkalla, S
    EVOLVING TECHNOLOGIES FOR THE COMPETITIVE EDGE, BOOKS 1 AND 2, 1997, 42 : 87 - 98
  • [48] Design of slender and squat reinforced concrete members with shear reinforcement
    Pejatovic, Marko
    Fernandez Ruiz, Miguel
    Muttoni, Aurelio
    STRUCTURAL CONCRETE, 2023, 24 (01) : 985 - 1001
  • [49] Flexural Behaviour of Lightweight Reinforced Concrete Beams Internally Reinforced with Welded Wire Mesh
    Chandramouli, Pavithra
    Muthukrishnan, Dinesh
    Sridhar, Venkatesh
    Kumar, Veerappan Sathish
    Murali, Gunasekaran
    Vatin, Nikolai Ivanovich
    BUILDINGS, 2022, 12 (09)
  • [50] Use of Welded Wire Reinforcement as Lateral Reinforcement in Concrete Beams: Part 2-Flexure
    Younes, Abdelaziz
    Tabsh, Sami W.
    Alhoubi, Yazan
    ACI STRUCTURAL JOURNAL, 2023, 120 (03) : 173 - 186