Ductility of Concrete Members Reinforced with Welded Wire Reinforcement (WWR)

被引:5
|
作者
Shwani, Mohamed [1 ]
Tawadrous, Raed [2 ]
Maguire, Marc [3 ]
机构
[1] Amer Univ Iraq, Sulaimani Kirkuk Main Rd, Sulaimani, Krg, Iraq
[2] EConstruct Florida, 3452 Lake Lynda Dr Suite 350, Orlando, FL 32817 USA
[3] Utah State Univ, Dept Civil & Environm Engn, Logan, UT 84322 USA
关键词
Welded wire reinforcement; Ductility; Strain localization; Failure mode; Reinforced concrete; SLABS;
D O I
10.1016/j.engstruct.2019.04.081
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Past research studies have been conducted on the ductility of concrete members reinforced with welded wire reinforcement (WWR) and determined a new phenomenon called strain localization reduces member ductility due to superior bond between WWR and concrete. Such studies have concluded that strain localization adversely affects the ductility of members reinforced with WWR and it is unsafe to use WWR as tension reinforcement. In this study, 50 simply-supported, concrete slabs with a representative slab width of 2 ft (610 mm), thickness of 7 in. (180 nun), and total length of 21 ft (6.4 m) were tested to further examine the strain localization phenomenon on global deformations. Two major parameters were investigated, cross-weld spacing and wire diameter. The impact of these two parameters on strength, ductility, and mode of failure of concrete members reinforced with WWR was also studied. Moment curvature analysis was used to estimate inelastic deflections and ductility to investigate the effect of the reinforcement total elongation at failure of the wire material on the overall member ductility. It was observed that members reinforced with WWR with cross-weld spacing of 14 in. (355 mm) or more had similar ductility as members reinforced with loose wires (without cross-weld). Members reinforced with WWR with closely spaced cross-weld (i.e., 3 or 7 in. (75 or 180 mm)) showed erratic and often less ductility, however, the wire itself was shown to have low ductility. Failure of members reinforced with WWR provided sufficient warning prior to failure as evidenced by the ductility ratios in excess of 2.5. Additionally, a moment-curvature analysis based parametric study showed that an acceptable level of ductility can be achieved with a minimum total elongation of wire reinforcement of 3% at failure.
引用
收藏
页码:711 / 723
页数:13
相关论文
共 50 条
  • [21] Experimental and analytical assessment of ductility in lightly reinforced concrete members
    Cashell, K. A.
    Elghazouli, A. Y.
    Izzuddin, B. A.
    ENGINEERING STRUCTURES, 2010, 32 (09) : 2729 - 2743
  • [22] Uncertainty analysis of strength and ductility of confined reinforced concrete members
    Kappos, AJ
    Chryssanthopoulos, MK
    Dymiotis, C
    ENGINEERING STRUCTURES, 1999, 21 (03) : 195 - 208
  • [23] Confinement of reinforced concrete columns with welded reinforcement grids
    Saatcioglu, M
    Grira, M
    ACI STRUCTURAL JOURNAL, 1999, 96 (01) : 29 - 39
  • [24] Effect of reinforcement type on the ductility of suspended reinforced concrete slabs
    Gilbert, R. Ian
    Sakka, Zafer I.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (06): : 834 - 843
  • [25] Minimum reinforcement and ductility index of lightly reinforced concrete beams
    Fantilli, Alessandro P.
    Chiaia, Bernardino
    Gorino, Andrea
    COMPUTERS AND CONCRETE, 2016, 18 (06): : 1175 - 1194
  • [26] New trends in concrete construction with welded wire fabric as reinforcement
    Syal, I.C.
    Syal, Rajiv
    Indian Concrete Journal, 1997, 71 (07): : 367 - 371
  • [27] Confinement of high-strength concrete with welded wire reinforcement
    Lambert-Aikhionbare, N
    Tabsh, SW
    ACI STRUCTURAL JOURNAL, 2001, 98 (05) : 677 - 685
  • [28] REINFORCEMENT BUCKLING IN REINFORCED-CONCRETE FLEXURAL MEMBERS
    SCRIBNER, CF
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1986, 83 (06): : 966 - 973
  • [29] INFLUENCE OF REINFORCEMENT COUPLERS ON THE CRACKING OF REINFORCED CONCRETE MEMBERS
    Jokubaitis, Vidmantas
    Juknevicius, Linas
    MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 10TH INTERNATIONAL CONFERENCE 2010, VOL II, 2010, : 646 - 650
  • [30] Fiber-Reinforced Polymer Reinforcement for Concrete Members
    Ekenel, Mahmut
    De Caso y Basalo, Francisco
    Nanni, Antonio
    Concrete International, 2021, 43 (02) : 18 - 22