Quantitative computed tomography (QCT) of the forearm using general purpose spiral whole-body CT scanners: Accuracy, precision and comparison with dual-energy X-ray absorptiometry (DXA)

被引:91
|
作者
Engelke, Klaus [1 ,2 ,3 ]
Libanati, Cesar [4 ]
Liu, Yu [4 ]
Wang, Huei [4 ]
Austin, Matt [4 ]
Fuerst, Tom [1 ,2 ]
Stampa, Bernd [1 ,2 ]
Timm, Wolfram [1 ,2 ]
Genant, Harry K. [1 ,2 ,5 ]
机构
[1] Synarc Inc, D-22087 Hamburg, Germany
[2] Synarc Inc, San Francisco, CA USA
[3] Univ Erlangen Nurnberg, Inst Med Phys, D-8520 Erlangen, Germany
[4] Amgen Inc, Thousand Oaks, CA 91320 USA
[5] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
Quantitative computed tomography; Bone mineral density; Bone geometry; Distal radius; Osteoporosis; BONE-MINERAL DENSITY; POSTMENOPAUSAL WOMEN; DISTAL RADIUS; SEGMENTATION METHOD; CLINICAL-USE; OSTEOPOROSIS; FRACTURES; STRENGTH; AGE; RISK;
D O I
10.1016/j.bone.2009.03.669
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Dual-energy X-ray absorptiometry (DXA) allows clinically relevant measurement of bone mineral density (BMD) at central and appendicular skeletal sites, but DXA has a limited ability to assess bone geometry and cannot distinguish between the Cortical and trabecular bone Compartments. Quantitative computed tomography (QCT) can supplement DXA by enabling geometric and compartmental bone assessments. Whole-body spiral CT scanners are widely available and require only seconds per scan, in contrast to peripheral QCT scanners, which have restricted availability, limited spatial resolution, and require several minutes of scanning time. This study evaluated the accuracy and precision of whole-body spiral CT scanners for quantitatively assessing the distal radius, a common site of non-vertebral osteoporosis-related fractures, and compared the CT-measured densitometric values with those obtained from dual-energy-X-ray absorptiometry. Subjects and methods: A total of 161 postmenopausal women with baseline lumbar spine BMD T-scores between -1.0 and -2.5 underwent left forearm QCT using whole-body spiral CT scanners twice, I month apart. QCT volumes of interest were defined and analyzed at 3 specific radial regions: the ultradistal region by using slices at 8, 9, and 10 mm proximal to the ulnar styloid tip; the distal region by a slice 20 mm proximal; and the middle region by a slice 40 mm proximal, BMD, bone mineral content (BMC), volume, and average cortical thickness and circumference were measured. We evaluated QCT accuracy and precision and also report correlations between QCT and DXA for BMD and BMC Results: Overall accuracy and precision errors for BMD, BMC and volume were consistent with known skeletal QCT technology precision and were generally less than 3%. BMD and BMC assessed by QCT and DXA were Correlated (r = 0.55 to 0.80). Discussion: Whole-body spiral CT scanners allow densitometric evaluations of the distal radius with good accuracy and very good precision. This original and convenient method provides a tool to further investigate cortical and trabecular bone variables in the peripheral skeleton in osteoporotic patients. These assessments, coupled with evaluation of the effects on cortical and trabecular bone measured in response to therapies for osteoporosis, may advance our understanding of the contributors to non-vertebral fracture Occurrence. (C) 2009 Published by Elsevier Inc.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 50 条
  • [31] Dual-energy X-ray Absorptiometry (DXA) for Body Composition Assessment. an Inter-instrument Comparison
    Ward, L. C.
    Rudorfer, C.
    Isenring, E.
    Kagawa, M.
    INTERNATIONAL JOURNAL OF OBESITY, 2011, 35 : S24 - S24
  • [32] COMPARISON OF RADIOGRAPHIC ABSORPTIOMETRY WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY IN NORMAL OLDER WHITE AND BLACK-WOMEN
    KLEEREKOPER, M
    NELSON, DA
    FLYNN, MJ
    PAWLUSZKA, AS
    JACOBSEN, G
    PETERSON, EL
    JOURNAL OF BONE AND MINERAL RESEARCH, 1994, 9 (11) : 1745 - 1749
  • [33] Whole-body Computed Tomography Versus Dual Energy X-ray Absorptiometry for Assessing Heterotopic Ossification in Fibrodysplasia Ossificans Progressiva
    Warner, Sarah E.
    Kaplan, Frederick S.
    Pignolo, Robert J.
    Smith, Stacy E.
    Hsiao, Edward C.
    De Cunto, Carmen
    Di Rocco, Maja
    Harnett, Kathleen
    Grogan, Donna
    Genant, Harry K.
    CALCIFIED TISSUE INTERNATIONAL, 2021, 109 (06) : 615 - 625
  • [34] PRECISION AND ACCURACY FOR RAT WHOLE-BODY AND FEMUR BONE-MINERAL DETERMINATION WITH DUAL X-RAY ABSORPTIOMETRY
    HAGIWARA, S
    LANE, N
    ENGELKE, K
    SEBASTIAN, A
    KIMMEL, DB
    GENANT, HK
    BONE AND MINERAL, 1993, 22 (01): : 57 - 68
  • [35] The prediction of visceral fat by dual-energy X-ray absorptiometry in the elderly: a comparison with computed tomography and anthropometry
    MB Snijder
    M Visser
    JM Dekker
    JC Seidell
    T Fuerst
    F Tylavsky
    J Cauley
    T Lang
    M Nevitt
    TB Harris
    International Journal of Obesity, 2002, 26 : 984 - 993
  • [36] The prediction of visceral fat by dual-energy X-ray absorptiometry in the elderly: a comparison with computed tomography and anthropometry
    Snijder, MB
    Visser, M
    Dekker, JM
    Seidell, JC
    Fuerst, T
    Tylavsky, F
    Cauley, J
    Lang, T
    Nevitt, M
    Harris, TB
    INTERNATIONAL JOURNAL OF OBESITY, 2002, 26 (07) : 984 - 993
  • [37] Measurement of the body composition of small piglets by quantitative magnetic resonance (QMR) and dual-energy X-ray absorptiometry (DXA)
    Mitchell, Alva
    Taicher, Gersh
    Kovner, Israel
    FASEB JOURNAL, 2009, 23
  • [38] Accuracy and precision of in vivo bone mineral measurements in sheep using dual-energy X-ray absorptiometry
    Pouilles, JM
    Collard, P
    Tremollieres, F
    Frayssinet, P
    Railhac, JJ
    Cahuzac, JP
    Autefage, A
    Ribot, C
    CALCIFIED TISSUE INTERNATIONAL, 2000, 66 (01) : 70 - 73
  • [39] Comparison of Lumbar Spine Bone Mineral Density Using Quantitative Computed Tomography and Dual-Energy X-Ray Absorptiometry in an Ovine Model of Osteoporosis
    Bisazza, Katie
    Nelson, Brad
    Sikes, Katie
    Stewart, Holly
    Easley, Jeremiah
    JOURNAL OF BONE AND MINERAL RESEARCH, 2023, 38 : 167 - 168
  • [40] Mechanical strength of the thoracolumbar spine in the elderly:: Prediction from in situ dual-energy X-ray absorptiometry, quantitative computed tomography (QCT), upper and lower limb peripheral QCT, and quantitative ultrasound
    Lochmüller, EM
    Bürklein, D
    Kuhn, V
    Glaser, C
    Müller, R
    Glüer, CC
    Eckstein, F
    BONE, 2002, 31 (01) : 77 - 84