Effect of autoclave sterilisation and heat activated sodium hypochlorite irrigation on the performance of nickel-titanium rotary files against cyclic fatigue

被引:1
|
作者
Ayad Jaber, Zuha [1 ]
Jabbar Abdul-Zahra Al-Hmedat, Sattar [1 ]
Hameed, Sarmad Adel [2 ]
Al-Nasrawi, Suhad Jabbar Hamed [1 ]
Aljdaimi, Abtesam Imhemed [3 ]
Haider, Julfikar [4 ]
机构
[1] Univ Kufa, Fac Dent, Dept Conservat Dent, Najaf, Iraq
[2] Univ Kufa, Fac Dent, Dept Oral Med & Oral Pathol, Al Najaf, Iraq
[3] Alasmarya Univ, Coll Dent & Oral Surg, Zliten, Libya
[4] Manchester Metropolitan Univ, Dept Engn, Manchester, Lancs, England
关键词
Endodontic nickel-titanium file; cyclic Fatigue; One Curve file; autoclave; sodium hypochlorite; heat activation;
D O I
10.1080/2374068X.2020.1848309
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The present study aims to assess the impact of heat-activated sodium hypochlorite (NaOCl) and/or autoclave sterilisation on the cyclic fatigue resistance (CFR) of heat-treated nickel-titanium rotary files used in root canal treatment. The CFR of One Curve (OC) files was evaluated under the following conditions: as received (Group 1; control), immersion in NaOCl at 23 +/- 1oC (Group 2), immersion in NaOCl at 60 +/- 1oC (Group 3), autoclave sterilisation at 135 1oC (Group 4), combined treatment of autoclave sterilisation and immersion in NaOCl at 23 +/- 1oC (Group 5), and combined treatment of autoclave sterilisation and immersion in NaOCl at 60 +/- 1oC (Group 6). A simulated root canal in a zirconia block was utilised to test the performance of the files. All the types of treatments resulted in significant reductions in fracture resistance of the OC files. Immersion of the files in NaOCl at 23oC revealed the smallest reduction, while combined treatment of autoclaving and immersion in NaOCl at 60oC caused the greatest reduction. Autoclave sterilisation or exposure of OC files to 2.5% NaOCl adversely affect the cyclic fatigue life and increasing solution temperature or combined treatment caused additionally significant reduction in CFR.
引用
收藏
页码:1071 / 1083
页数:13
相关论文
共 50 条
  • [41] Impact of pecking amplitude on cyclic fatigue of new nickel-titanium files
    Pedulla, Eugenio
    Carlesi, Teocrito
    Pappalardo, Alfio
    Canova, Francesco Saverio
    Malagnino, Vito Antonio
    La Rosa, Giusy Rita Maria
    Generali, Luigi
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (01):
  • [42] Effect of Autoclaving Cycles on the Cyclic Fatigue Resistance of Race and Race Evo Nickel-Titanium Endodontic Rotary Files: An In Vitro Study
    Almohareb, Rahaf A.
    Barakat, Reem
    Albakri, Aroob
    Altamimi, Manal
    METALS, 2021, 11 (12)
  • [43] Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files (vol 48, pg 1100, 2015)
    Lee, S. H.
    Park, Y. G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (02) : 220 - 220
  • [44] Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments
    Ullmann, CJ
    Peters, OA
    JOURNAL OF ENDODONTICS, 2005, 31 (03) : 183 - 186
  • [45] Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments
    Ounsi, Hani F.
    Salameh, Ziad
    Al-Shalan, Thakib
    Ferrari, Marco
    Grandini, Simone
    Pashley, David H.
    Tay, Franklin R.
    JOURNAL OF ENDODONTICS, 2007, 33 (06) : 737 - 741
  • [46] Effect of Different Heat Treatments and Surface Treatments on the Mechanical Properties of Nickel-Titanium Rotary Files
    Hong, Jihye
    Kwak, Sang Won
    Ha, Jung-Hong
    Sigurdsson, Asgeir
    Shen, Ya
    Kim, Hyeon-Cheol
    METALS, 2023, 13 (10)
  • [47] Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files
    Rapisarda, E
    Bonaccorso, A
    Tripi, TR
    Condorelli, GG
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (03): : 343 - 347
  • [48] Effect of experience on quality of canal preparation with rotary nickel-titanium files
    Baumann, MA
    Roth, A
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (06): : 714 - 718
  • [49] Effect of flushing temperature on preparation ability of rotary nickel-titanium files
    Chai, Guangquan
    Guo, Ziyan
    Wang, Yingdi
    Li, Yanfeng
    Wang, Jing
    Zhang, Lu
    Sun, Yidan
    Yang, Chunhao
    Xia, Dong
    Shi, Tingting
    JOURNAL OF APPLIED BIOMATERIALS & FUNCTIONAL MATERIALS, 2021, 19
  • [50] Cyclic Fatigue of Different Nickel-Titanium Rotary Instruments: A Comparative Study
    Testarelli, L.
    Grande, N. M.
    Plotino, G.
    Lendini, M.
    Pongione, G.
    De Paolis, G.
    Rizzo, F.
    Milana, V.
    Gambarini, G.
    OPEN DENTISTRY JOURNAL, 2009, 3 : 55 - 58