Effect of autoclave sterilisation and heat activated sodium hypochlorite irrigation on the performance of nickel-titanium rotary files against cyclic fatigue

被引:1
|
作者
Ayad Jaber, Zuha [1 ]
Jabbar Abdul-Zahra Al-Hmedat, Sattar [1 ]
Hameed, Sarmad Adel [2 ]
Al-Nasrawi, Suhad Jabbar Hamed [1 ]
Aljdaimi, Abtesam Imhemed [3 ]
Haider, Julfikar [4 ]
机构
[1] Univ Kufa, Fac Dent, Dept Conservat Dent, Najaf, Iraq
[2] Univ Kufa, Fac Dent, Dept Oral Med & Oral Pathol, Al Najaf, Iraq
[3] Alasmarya Univ, Coll Dent & Oral Surg, Zliten, Libya
[4] Manchester Metropolitan Univ, Dept Engn, Manchester, Lancs, England
关键词
Endodontic nickel-titanium file; cyclic Fatigue; One Curve file; autoclave; sodium hypochlorite; heat activation;
D O I
10.1080/2374068X.2020.1848309
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The present study aims to assess the impact of heat-activated sodium hypochlorite (NaOCl) and/or autoclave sterilisation on the cyclic fatigue resistance (CFR) of heat-treated nickel-titanium rotary files used in root canal treatment. The CFR of One Curve (OC) files was evaluated under the following conditions: as received (Group 1; control), immersion in NaOCl at 23 +/- 1oC (Group 2), immersion in NaOCl at 60 +/- 1oC (Group 3), autoclave sterilisation at 135 1oC (Group 4), combined treatment of autoclave sterilisation and immersion in NaOCl at 23 +/- 1oC (Group 5), and combined treatment of autoclave sterilisation and immersion in NaOCl at 60 +/- 1oC (Group 6). A simulated root canal in a zirconia block was utilised to test the performance of the files. All the types of treatments resulted in significant reductions in fracture resistance of the OC files. Immersion of the files in NaOCl at 23oC revealed the smallest reduction, while combined treatment of autoclaving and immersion in NaOCl at 60oC caused the greatest reduction. Autoclave sterilisation or exposure of OC files to 2.5% NaOCl adversely affect the cyclic fatigue life and increasing solution temperature or combined treatment caused additionally significant reduction in CFR.
引用
收藏
页码:1071 / 1083
页数:13
相关论文
共 50 条
  • [21] The Effect of Temperature on Cyclic Fatigue of Nickel-titanium Rotary Endodontic Instruments
    Dosanjh, Amandeep
    Paurazas, Susan
    Askar, Mazin
    JOURNAL OF ENDODONTICS, 2017, 43 (05) : 823 - 826
  • [22] Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files
    Silvaggio, J
    Hicks, ML
    JOURNAL OF ENDODONTICS, 1997, 23 (12) : 731 - 734
  • [23] Cyclic fatigue behavior of nickel-titanium dental rotary files in clinical simulated root canals
    Chi, Chih-Wen
    Li, Chun-Chieh
    Lin, Chun-Pin
    Shin, Chow-Shing
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2017, 116 (04) : 306 - 312
  • [24] Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Instruments after Immersion in Sodium Hypochlorite and/or Sterilization
    Pedulla, Eugenio
    Benites, Angela
    La Rosa, Giusy M.
    Plotino, Gianluca
    Grande, Nicola M.
    Rapisarda, Ernesto
    Generali, Luigi
    JOURNAL OF ENDODONTICS, 2018, 44 (04) : 648 - 653
  • [25] Effect of the temperature of sodium hypochlorite on the cyclic fatigue resistance of ProTaper Gold rotary files
    Mousavi, Seyed Amir
    Norouzi, Niloofar
    Memarzadeh, Bahareh
    Havaei, Seyed Rohollah
    Yousefshahi, Hazhir
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (04) : 533 - 537
  • [26] Effect of immersion in sodium hypochlorite on torque and fatigue resistance of nickel-titanium instruments
    Peters, Ove A.
    Roehlike, Jan O.
    Baumann, Michael A.
    JOURNAL OF ENDODONTICS, 2007, 33 (05) : 589 - 593
  • [27] Effect of sodium hypochlorite on conventional and heat-treated nickel-titanium endodontic rotary instruments - An in vitro study
    Lin, Jack Han-Hsing
    Karabucak, Bekir
    Lee, Su-Min
    JOURNAL OF DENTAL SCIENCES, 2021, 16 (02) : 738 - 743
  • [28] Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel-Titanium instruments
    Zhao, D.
    Shen, Y.
    Peng, B.
    Haapasalo, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (10) : 990 - 995
  • [29] Effects of Chitosan, NaOCl, and EDTA Irrigation Solutions on the Cyclic Fatigue Resistance of Three Nickel-Titanium Endodontic Rotary Files: An In Vitro Study
    Salloom, Wisam S.
    Shukri, Biland M. S.
    DENTAL HYPOTHESES, 2022, 13 (04): : 121 - 123
  • [30] Effect of Repeated Autoclaving on Cyclic Fatigue of Three Nickel-Titanium Rotary Instruments
    Elbatal, Laila M.
    El Batouty, Kariem Mostafa
    Obeid, Maram Mohamed
    ENDO-ENDODONTIC PRACTICE TODAY, 2016, 10 (01): : 15 - 22