Surface plasmon resonance based highly sensitive gold coated PCF biosensor

被引:35
|
作者
Islam, Mohammad Rakibul [1 ]
Iftekher, A. N. M. [1 ]
Hasan, Kazi Rakibul [1 ]
Nayen, Md Julkar [1 ]
Bin Islam, Saimon [1 ]
Islam, Rakina [1 ]
Khan, Raisa Labiba [1 ]
Moazzam, Ehtesam [1 ]
Tasnim, Zarrin [1 ]
机构
[1] Islamic Univ Technol, Dept Elect & Elect Engn, Boardbazar Gazipur 1704, Bangladesh
来源
关键词
Surface plasmon resonance; Optical fiber sensors; Photonic crystal fiber; Sensitivity; Resolution;
D O I
10.1007/s00339-020-04162-5
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A highly sensitive surface plasmon resonance-based PCF biosensor is explored in this research work. Outside the fiber frame, active plasmonic material gold (Au) with a thickness of 25 nm has been deposited which is chemically steady and is the primary sensing layer of the presented sensor. Unknown analytes could be detected by being flown on the metal surface or leaked onto the metal layer's outer surface. In this paper, we used circular airholes for external sensing of the unknown analyte. The suggested sensor obtains the maximum wavelength sensitivity of 14,500 nm / RIU in X-polarization mode and the maximum amplitude sensitivity of 4738.9 RIU-1 for Y-polarized mode, respectively in the spectrum of 1.35-1.41 for the analyte refractive index (RI). The lowest wavelength sensor resolution offered by this sensor is 6.9x10-6 RIU and the lowest amplitude sensor resolution is 2.11x10(-6) RIU for Y-polarized mode with FOM of 387 and 364 for X and Y polarization. In the presence of a perfectly matched layer (PML), the sensing output of the presented sensor is analyzed using the finite element method (FEM) based software named COMSOL Multiphysics version 5.3a. From our simulation result, it is important to note that the proposed sensor demonstrates a noteworthy sensor performance for both polarization modes so that the choice of light sources during the practical implementation is more frequent. The findings also show some bright features that our proposed sensor can detect organic chemicals, biochemical analytes and can also be used in medical diagnostics immensely.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Graphene coated high sensitive surface plasmon resonance biosensor for sensing DNA hybridization
    Hossain, Biplob
    Rana, Masud
    [J]. Sensor Letters, 2016, 14 (02) : 145 - 152
  • [22] Highly sensitive nano-porous lattice biosensor based on localized surface plasmon resonance and interference
    Yeom, Se-Hyuk
    Kim, Ok-Geun
    Kang, Byoung-Ho
    Kim, Kyu-Jin
    Yuan, Heng
    Kwon, Dae-Hyuk
    Kim, Hak-Rin
    Kang, Shin-Won
    [J]. OPTICS EXPRESS, 2011, 19 (23): : 22882 - 22891
  • [23] Highly sensitive surface plasmon resonance biosensor based on a low-index polymer optical fiber
    Cao, Shaoqing
    Shao, Yu
    Wang, Ying
    Wu, Tiesheng
    Zhang, Longfei
    Huang, Yijian
    Zhang, Feng
    Liao, Changrui
    He, Jun
    Wang, Yiping
    [J]. OPTICS EXPRESS, 2018, 26 (04): : 3988 - 3994
  • [24] Highly sensitive differential phase-sensitive surface plasmon resonance biosensor based on the Mach-Zehnder configuration
    Wu, SY
    Ho, HP
    Law, WC
    Lin, CL
    Kong, SK
    [J]. OPTICS LETTERS, 2004, 29 (20) : 2378 - 2380
  • [25] Phase-stepping technique for highly sensitive microscopic surface plasmon resonance biosensor
    Zhang, Chonglei
    Wang, Rong
    Wang, Yijia
    Zhu, Siwei
    Min, Changjun
    Yuan, X. -C.
    [J]. APPLIED OPTICS, 2014, 53 (05) : 836 - 840
  • [26] Highly Sensitive Surface Plasmon Resonance Biosensor Using WSe2 and Silicon
    Nur, Jannati Nabiha
    Asrafy, Fairuj
    Shushama, Kamrun Nahar
    [J]. 2018 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION & COMMUNICATION TECHNOLOGY (ICEEICT), 2018, : 246 - 250
  • [27] Design of an asymmetric gold-coated photonic crystal fiber (PCF) polarization filter based on surface plasmon resonance (SPR)
    Yang, Dan
    Wei, Zhulin
    Xu, Bin
    Cheng, Tonglei
    [J]. INSTRUMENTATION SCIENCE & TECHNOLOGY, 2021, 50 (03) : 306 - 320
  • [28] Performance Analysis Of Circular Lattice PCF Biosensor Using Surface Plasmon Resonance
    Fouthika, V.
    Samtindiswary, P.
    Sivasindhu, M.
    [J]. 2019 INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATION AND INFORMATICS (ICCCI - 2019), 2019,
  • [29] Highly sensitive graphene biosensors based on surface plasmon resonance
    Wu, L.
    Chu, H. S.
    Koh, W. S.
    Li, E. P.
    [J]. OPTICS EXPRESS, 2010, 18 (14): : 14395 - 14400
  • [30] Graphene Coated Photonic Crystal Fiber Biosensor Based on Surface Plasmon Resonance
    Paul, Alok Kumar
    Sarkar, Ajay Krishno
    Razzak, S. M. Abdur
    [J]. 2017 IEEE REGION 10 HUMANITARIAN TECHNOLOGY CONFERENCE (R10-HTC), 2017, : 856 - 859