Overvoltages in secondary circuits of medium-voltage switchgear generated by multiple reignitions of circuit breakers

被引:5
|
作者
Hardt, N [1 ]
Koenig, D [1 ]
机构
[1] Tech Univ Darmstadt, High Voltage Lab, D-64283 Darmstadt, Germany
关键词
EMC in substations; transient overvoltages;
D O I
10.1109/15.809855
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
During switching operations in the high-voltage system, transient voltages and currents occur that can generate overvoltages in the secondary circuits of switchgear. The investigations reported in this article are focused on medium-voltage air-insulated switchgear, The introduced model is able to identify the coupling mechanisms. The coupling,ia the instrument transformers and the secondary wiring to the electronic equipment is described. At first, the frequency-dependent coupling is explained for each secondary component. These are instrument transformers, the secondary wiring, and the electronic equipment. Then it is shown how to combine these components in order to get a complete description of the interfering mechanisms.
引用
收藏
页码:510 / 515
页数:6
相关论文
共 50 条
  • [31] PRINCIPLES AND APPLICATIONS OF BROWN BOVERI MEDIUM-VOLTAGE SWITCHGEAR
    KEINERT, L
    KOHLER, E
    [J]. BROWN BOVERI REVIEW, 1978, 65 (04): : 209 - 219
  • [32] ELECTROMAGNETIC COMPATIBILITY - A VITAL ISSUE FOR MEDIUM-VOLTAGE SWITCHGEAR
    Mueller, Ansgar
    Noeldner, Oliver
    [J]. 2012 PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE EUROPE CONFERENCE PROCEEDINGS (PCIC EUROPE), 2012,
  • [33] New Approaches for Maintenance Grounding in Medium-Voltage Switchgear
    Richard, Joe
    Mabius, David
    [J]. AISTECH 2013: PROCEEDINGS OF THE IRON & STEEL TECHNOLOGY CONFERENCE, VOLS I AND II, 2013, : 2309 - 2315
  • [34] Choosing medium-voltage circuit-breakers based on IEC60909 short-circuit calculations
    Cosse, RE
    Hazel, TG
    Youssef, R
    [J]. IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 2798 - 2805
  • [35] Solid-state circuit breakers and current-limiting devices for medium-voltage systems
    Schröder, S
    Meyer, C
    De Doncker, RW
    [J]. IEEE INTERNATIONAL POWER ELECTRONICS CONGRESS, TECHNICAL PROCEEDINGS, 2002, : 91 - 95
  • [36] Lightning-Induced Overvoltages on Overhead Medium-Voltage Lines
    Piantini, Alexandre
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [37] Directions of Development of Diagnostic Methods of Vacuum Medium-Voltage Switchgear
    Wegierek, Pawel
    Kostyla, Damian
    Lech, Michal
    [J]. ENERGIES, 2023, 16 (05)
  • [38] On-line condition monitoring system of medium-voltage switchgear
    Shi, ZQ
    Meng, YP
    Yang, W
    Ding, D
    Jia, SL
    Rong, MZ
    Cheng, YH
    [J]. IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 2290 - 2294
  • [39] Pure Air - the Alternative for the next Eeneration of Medium-voltage Switchgear
    Haim, M.
    Summer, R.
    [J]. ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2021, 138 (08): : 643 - 645
  • [40] MANAGING ARC FLASH Collaborative solutions in medium-voltage switchgear
    Krause, Kenneth
    Burns, David
    Hutchinson, Scott
    Arvola, Juha
    [J]. IEEE INDUSTRY APPLICATIONS MAGAZINE, 2014, 20 (01) : 70 - 78