Switchgear is one of the key equipments of electrical power system. Its operation condition is very important for system reliability. Mechanical failure (open rejecting, close rejecting, and mechanical malfunction), insulation failure, and contacts overheating are in the majority of all operation failures. In this paper, an on-line condition monitoring system for 12kV switchgear is developed. In this system, the insulation condition of bushings, the temperature rise of the detachable contacts and the mechanical performance are detected on-line. For mechanical performance, the contact travel and the current of close and open release coils are detected. Thus the average speed and instant speed can be got from contact travel. A prototype of this on-line condition monitoring system has been developed. Experiments indicate that the monitoring system can perform accurate on-line detection of operation condition of switchgear, and it can offer exact forecasting in time.
引用
收藏
页码:2290 / 2294
页数:5
相关论文
共 50 条
  • [1] On-site Online Condition Monitoring of Medium-Voltage Switchgear Units
    Nicolaou, Christina
    Mansour, Ahmad
    Van Laerhoven, Kristof
    [J]. 11TH INTERNATIONAL CONFERENCE ON THE INTERNET OF THINGS, IOT 2021, 2021, : 1 - 8
  • [2] Development of on-line monitoring equipment of medium voltage switchgear
    Huang Xiping
    Wang Xin
    Qiang Wen
    [J]. ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL III, 2007, : 388 - +
  • [3] MEDIUM-VOLTAGE SWITCHGEAR CUBICLES
    POOLE, D
    MUNZINGER, K
    [J]. BROWN BOVERI REVIEW, 1984, 71 (1-2): : 54 - 61
  • [4] Review of Medium-Voltage Switchgear Fault Detection in a Condition-Based Monitoring System by Using Deep Learning
    Alsumaidaee, Yaseen Ahmed Mohammed
    Yaw, Chong Tak
    Koh, Siaw Paw
    Tiong, Sieh Kiong
    Chen, Chai Phing
    Ali, Kharudin
    [J]. ENERGIES, 2022, 15 (18)
  • [5] The idea of system control and monitoring of a complete medium-voltage switchgear with solid insulation
    Shul’ga R.N.
    Shul’ga A.R.
    Kovalev D.I.
    Khrenov S.I.
    Koshelev M.A.
    [J]. Russian Electrical Engineering, 2017, 88 (8) : 509 - 514
  • [6] A NEW GENERATION OF MEDIUM-VOLTAGE SWITCHGEAR
    HOYER, P
    KRAMER, W
    [J]. BROWN BOVERI REVIEW, 1985, 72 (01): : 24 - 28
  • [7] DEVELOPMENT TRENDS IN MEDIUM-VOLTAGE SWITCHGEAR
    PAULS, H
    HACKENSCHMIDT, K
    [J]. BROWN BOVERI REVIEW, 1986, 73 (11): : 621 - 628
  • [8] On-line Monitoring and Evaluation of Mechanical Characteristic Condition of Switchgear
    You, Yi-min
    Li, Jia
    Lin, Ming-rui
    Liu, Jing-an
    Ouyang, Zhen-guo
    [J]. 2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [9] ALTERNATIVE INSULATION GAS FOR MEDIUM-VOLTAGE SWITCHGEAR
    Hyrenbach, Maik
    Zache, Sebastian
    [J]. 2016 PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE EUROPE (PCIC EUROPE), 2016,
  • [10] Recent topics of the medium-voltage switchgear in Japan
    Morita, A
    [J]. IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 1450 - 1454