Comparison of point-of-care and central laboratory analyzers for blood gas and lactate measurements

被引:12
|
作者
Indrasari, Nuri Dyah [1 ]
Wonohutomo, Jessica Purwanti [1 ]
Sukartini, Ninik [1 ]
机构
[1] Univ Indonesia, Cipto Mangunkusumo Natl Referral Hosp, Clin Pathol Dept, Fac Med, Jakarta, Indonesia
关键词
blood gas; inter-device variability; i-STAT; lactate; Nova pHOx plus L;
D O I
10.1002/jcla.22885
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Blood gas analysis and blood lactate measurement have important roles in patient management. Point-of-care (POC) testing simplifies and provides rapid blood gas and lactate measurements. This study aimed to compare pH, pCO(2), pO(2), and lactate measurements between a POC device and a benchtop blood gas analyzer typically used in a hospital central laboratory, and to evaluate the inter-device variability of the POC device. Methods A cross-sectional study was conducted with a sample size of 100. Each sample was measured for pH, pCO(2), pO(2), and lactate using a Nova pHOx plus L benchtop blood gas analyzer in the central laboratory and an i-STAT handheld POC device. The results of both devices were compared using Pearson or Spearman correlation coefficients and Bland-Altman tests. Testing of the inter-device variability was done by using three different i-STAT devices, and the results were compared statistically. Results Strong correlations were observed for all test results. In Bland-Altman analysis, >= 95% of the results were within the limits of agreement, with the exception of lactate, which had only 93%. The results that were beyond the limits were primarily lactate levels >8 mmol/L. Biases between the benchtop analyzer and the i-STAT were not clinically significant, except pH. No significant inter-device variability was observed between the i-STAT analyzers. Conclusion This comparison study of pH, pCO(2), pO(2), and lactate measurements between Nova pHOx plus L and i-STAT analyzers showed good agreement. However, lactate measurement results >8 mmol/L on the i-STAT analyzer should be interpreted with caution.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Evaluation of the LABGEO PT10 Point-Of-Care Testing Device: Comparison of Analyte Measurements in Capillary Whole Blood and Lithium Heparin Whole Blood Samples With Those in Central Laboratory
    Lim, Jinsook
    Kim, Hyunjin
    Koo, Sun Hoe
    Kwon, Gye Cheol
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2017, 31 (03)
  • [42] The preanalytical phase should be carefully assessed during the comparisons of point-of-care versus central laboratory measurements
    Auvet, Adrien
    Simundic, Ana-Maria
    Guillon, Antoine
    [J]. HEART & LUNG, 2017, 46 (05): : 402 - 403
  • [43] Performance and reliability of two frequently used point-of-care blood gas analyzers at 423 and 4,559 m
    Treff, Gunnar
    Treff, Franziska
    Sareban, Mahdi
    Schiefer, Lisa M.
    Schaefer, Larissa
    Schmidt, Peter
    Niebauer, Josef
    Steinacker, Juergen M.
    Swenson, Erik R.
    Swenson, Kai E.
    Mayer, Benjamin
    Berger, Marc M.
    [J]. CLINICAL BIOCHEMISTRY, 2023, 116 : 38 - 41
  • [44] Point-of-care Laboratory Testing
    Gauglitz, Guenter
    Luppa, Peter B.
    [J]. CHEMIE IN UNSERER ZEIT, 2009, 43 (05) : 308 - 318
  • [45] Point-of-care laboratory instruments
    Wallen, Roy D.
    [J]. Biomedical Instrumentation and Technology, 2007, 41 (01): : 62 - 64
  • [46] COMPARISON OF TWO POINT-OF-CARE INR DEVICES AND LABORATORY METHOD
    Vazquez, Sara R.
    Fleming, Ryan
    Johnson, Stacy A.
    [J]. AMERICAN JOURNAL OF HEMATOLOGY, 2016, 91 (09) : E364 - E365
  • [47] Comparison of pleural fluid pH measurements: blood gas analyzer, pH indicator stick, litmus paper, and point-of-care testing for blood gases
    Kim, Sang-Ha
    Shin, Beomsu
    Lee, Seok Jeong
    Lee, Myoung Kyu
    Lee, Won-Yeon
    Yong, Suk Joong
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [48] Point-of-Care Measurements on a Neonatal Intensive Care Unit Using the OMNI-S Blood Gas Analyzer
    Arthurs, Owen
    Dey, Prakash
    Pattnayak, Santosh
    Bewley, Barbara
    MacDonald, Audrey
    Kelsall, Wilf
    [J]. POINT OF CARE, 2007, 6 (02): : 112 - 117
  • [49] Comparison of two point-of-care lipid analyzers for use in global cardiovascular risk assessments
    Dale, Rita A.
    Jensen, Lisa H.
    Krantz, Mori J.
    [J]. ANNALS OF PHARMACOTHERAPY, 2008, 42 (05) : 633 - 639
  • [50] Accuracy of point-of-care blood glucose measurements in the medical ICU
    Y Liu
    D Wu
    X Song
    Y Meng
    L Weng
    B Du
    [J]. Critical Care, 12 (Suppl 2):