Evaluation of the LABGEO PT10 Point-Of-Care Testing Device: Comparison of Analyte Measurements in Capillary Whole Blood and Lithium Heparin Whole Blood Samples With Those in Central Laboratory

被引:0
|
作者
Lim, Jinsook [1 ]
Kim, Hyunjin [1 ]
Koo, Sun Hoe [1 ]
Kwon, Gye Cheol [1 ]
机构
[1] Chungnam Natl Univ Hosp, Dept Lab Med, 33 Munhwa Ro, Daejeon 35015, South Korea
关键词
Analytic chemistry technique; capillary blood; POCT; point-of-care testing; PERFORMANCE; POCT;
D O I
10.1002/jcla.22050
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Point-of-care (POC) testing device has been widely used because of its rapid availability of results making diagnosis and management as early as possible. Capillary blood can reduce the difficulty of obtaining samples compared to venous blood and allows the prompt testing results. In this study, we evaluated the usefulness of capillary blood in Samsung LABGEO PT10. Methods: Fifty-one patients and 18 healthy adults aged between 20 and 65 were enrolled and their capillary and venous blood samples were collected. Venous blood samples were split into lithium heparin (LiHep) tube and serumseparating tube. Measurements using capillary blood and LiHep whole blood were performed in LABGEO PT10. Serum was used for measurement by Toshiba 2000FR NEO in central laboratory. Results: In comparison between measurements in LABGEO PT10 using capillary and LiHep whole blood, the slope ranged between 0.9289 and 1.0471, correlation coefficients (R-2) were over 0.95 except albumin, high-density lipoprotein, and total protein. Comparison of measurements in capillary and LiHep whole blood using LABGEO PT10 with those in the central laboratory revealed that the slope ranged between 0.6433 and 1.1364 for capillary whole blood and 0.6255 and 1.1602 for LiHep whole blood except alkaline phosphatase. For most of analytes, R-2 were over 0.95. Conclusion: Measurements in LABGEO PT10 using capillary blood was well correlated with those in LABGEO PT10 using LiHep whole blood and also with in the central laboratory. In conclusion, capillary blood provides reliable measurements and can be trustfully used in LABGEO PT10. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页数:11
相关论文
共 37 条
  • [1] PORTABLE SIMULTANEOUS MULTIPLE ANALYTE WHOLE-BLOOD ANALYZER FOR POINT-OF-CARE TESTING
    SCHEMBRI, CT
    OSTOICH, V
    LINGANE, PJ
    BURD, TL
    BUHL, SN
    [J]. CLINICAL CHEMISTRY, 1992, 38 (09) : 1665 - 1670
  • [2] A novel point-of-care device accurately measures thyrotropin in whole blood, capillary blood and serum
    Kahaly, George J.
    Lotz, Johannes
    Walder, Sara
    Hammad, Cara
    Kraemer, Rebecca
    Frommer, Lara
    Koenig, Jochem
    Wolf, Jan
    Gottwald-Hostalek, Ulrike
    Urgatz, Bogumila
    Lackner, Karl J.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (10) : 1607 - 1616
  • [3] Hemolysis Rates in Whole Blood Samples for Blood Gas/Electrolyte Analysis by Point-of-Care Testing
    Wilson, Amanda
    Sweeney, Maranna
    Lynch, P. L. Mark
    O'Kane, Maurice J.
    [J]. JOURNAL OF APPLIED LABORATORY MEDICINE, 2018, 3 (01): : 144 - 145
  • [4] A lab-on-a-CD system for point-of-care testing of whole blood samples
    Jun Yang
    [J]. 医用生物力学, 2013, 28(S1) (S1) : 79 - 79
  • [5] Clinical evaluation of the first medical whole blood, point-of-care testing device for detection of myocardial infarction
    Apple, FS
    Anderson, FP
    Collinson, P
    Jesse, RL
    Kontos, MC
    Levitt, MA
    Miller, EA
    Murakami, MM
    [J]. CLINICAL CHEMISTRY, 2000, 46 (10) : 1604 - 1609
  • [6] Comparison of point-of-care and central laboratory analyzers for blood gas and lactate measurements
    Indrasari, Nuri Dyah
    Wonohutomo, Jessica Purwanti
    Sukartini, Ninik
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2019, 33 (05)
  • [7] Comparison of Result Times Between Urine and Whole Blood Point-of-care Pregnancy Testing
    Gottlieb, Michael
    Wnek, Kristopher
    Moskoff, Jordan
    Christian, Errick
    Bailitz, John
    [J]. WESTERN JOURNAL OF EMERGENCY MEDICINE, 2016, 17 (02) : 449 - 453
  • [8] Evaluation of the i-STAT point-of-care capillary whole blood prothrombin time and international normalized ratio: Comparison to the Tcoag MDAII coagulation analyzer in the central laboratory
    Pena, J. A.
    Lewandrowski, K. B.
    Lewandrowski, E. L.
    Gregory, K.
    Baron, J. M.
    Van Cott, E. M.
    [J]. CLINICA CHIMICA ACTA, 2012, 413 (11-12) : 955 - 959
  • [9] An Erbium:YAG laser to obtain capillary blood samples without a needle for point-of-care laboratory testing
    Fonseca, V
    Hinson, J
    Pappas, A
    Waner, M
    Flock, S
    [J]. ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1997, 121 (07) : 685 - 688
  • [10] A Comparison Study Between Point-of-Care Testing Systems and Central Laboratory for Determining Blood Glucose in Venous Blood
    Wei, Huiping
    Lan, Fang
    He, Qitian
    Li, Haiwei
    Zhang, Fuyong
    Qin, Xue
    Li, Shan
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2017, 31 (03)