An Erbium:YAG laser to obtain capillary blood samples without a needle for point-of-care laboratory testing

被引:0
|
作者
Fonseca, V
Hinson, J
Pappas, A
Waner, M
Flock, S
机构
[1] UNIV ARKANSAS MED SCI HOSP,DEPT MED,DIV ENDOCRINOL,LITTLE ROCK,AR 72205
[2] UNIV ARKANSAS MED SCI HOSP,DEPT PATHOL,LITTLE ROCK,AR 72205
[3] UNIV ARKANSAS MED SCI HOSP,DEPT OTOLARYNGOL HEAD & NECK SURG,LITTLE ROCK,AR 72205
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background. - Needlestick injury poses an occupational hazard to health care workers that will increase with the increasing availability of point-of-care testing using capillary blood obtained with a lancet. Objectives. - To demonstrate the safety and efficacy of a portable pulsed erbium : yttrium-aluminum-garnet (Er: YAC) laser in obtaining a blood sample from patients in a clinical setting and to determine whether the laser radiant energy alters the level of various components of blood, resulting in misleading laboratory results. Design. - Comparison of laboratory values of blood samples obtained with the laser and conventional lancet and comparison of patient and user preferences by questionnaire. Patients and Methods. - One hundred patients with diabetes mellitus attending a diabetes clinic were randomized to have capillary blood sampling from the fingertip performed either by the laser or a conventional lancet first, then with the other device. Main Outcome Measures. - A comparison of pain, healing, hematocrit, and glycosylated hemoglobin (HbAlc), blood urea nitrogen, sodium, potassium, bicarbonate, and glucose levels. Results. - Adequate blood was obtained with both devices 97% of the time. Blood flow was greater with the laser perforation, resulting in higher operator preference. Although patients felt greater pain and experienced slower healing with the laser, these were not serious problems. Modification of the laser energy output led to a reduction in pain. Possibly owing to hemolysis,the potassium level in the blood obtained with the laser was significantly elevated and unsuitable for clinical decision making in many cases. None of the other measurements were similarly affected. Conclusions. - We conclude that the laser device has the potential to obtain a blood sample for routine tests without a needle. This needle-free method will decrease the risk of bloodborne infections caused by needlestick injuries and thus lead to considerable cost savings and public health advantages. Further work is needed to alter the laser energy so that hemolysis can be decreased, thus enabling a more reliable potassium estimation.
引用
收藏
页码:685 / 688
页数:4
相关论文
共 50 条
  • [1] Capillary blood for point-of-care testing
    Tang, Ruihua
    Yang, Hui
    Choi, Jane Ru
    Gong, Yan
    You, MinLi
    Wen, Ting
    Li, Ang
    Li, XiuJun
    Xu, Bo
    Zhang, Sufeng
    Mei, Qibing
    Xu, Feng
    [J]. CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 2017, 54 (05) : 294 - 308
  • [2] Point-of-care Laboratory Testing
    Gauglitz, Guenter
    Luppa, Peter B.
    [J]. CHEMIE IN UNSERER ZEIT, 2009, 43 (05) : 308 - 318
  • [3] Could capillary point-of-care hCG testing act as a substitute for laboratory testing in early pregnancy care?
    Pikovsky, M.
    Kyriacou, C.
    Bobdiwala, S.
    Parker, N.
    Novak, A.
    Barcroft, J.
    Al-Memar, M.
    Sur, S.
    Stalder, C.
    Bourne, T.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 53 - 54
  • [4] Point-of-Care Testing of Blood Glucose: Clinical Performance and Laboratory Efficiency
    Shih, Wei-Shang
    Yang, Pei-Fang
    Chi, Tzu-Fei
    Huang, Liang Li
    Chen, Chang-I
    Wang, Mei-Xuan
    Ho, Yi-Ting
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (09) : BC10 - BC13
  • [5] A comparative study between point-of-care hemoglobin (capillary samples) and laboratory hemoglobin result (venous samples)
    Yu, Chun Hiu
    Lam, Shing Kit Tommy
    [J]. HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2024,
  • [6] Point-of-Care Testing Devices for Heart Failure Analyzing Blood and Saliva Samples
    Tripoliti, Evanthia E.
    Ioannidou, Penelope
    Toumpaniaris, Petros
    Rammos, Aidonis
    Pacitto, Dominique
    Lourme, Jean-Christophe
    Goletsis, Yorgos
    Naka, Katerina K.
    Errachid, Abdelhamid
    Fotiadis, Dimitrios, I
    [J]. IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2020, 13 : 17 - 31
  • [7] A lab-on-a-CD system for point-of-care testing of whole blood samples
    Jun Yang
    [J]. 医用生物力学, 2013, 28(S1) (S1) : 79 - 79
  • [8] Point-of-care analysis of intraosseous blood samples
    Jousi, Milla
    Nurmi, Jouni
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2019, 63 (08) : E21 - E21
  • [9] Accuracy of a point of care compact device for hematocrit testing in capillary blood samples
    Apiratmateekul, N.
    Duanginta, W.
    Chuaychoo, P.
    Kongros, K.
    Treebuphachatsakul, W.
    [J]. CLINICA CHIMICA ACTA, 2022, 530 : S111 - S112
  • [10] Hemolysis Rates in Whole Blood Samples for Blood Gas/Electrolyte Analysis by Point-of-Care Testing
    Wilson, Amanda
    Sweeney, Maranna
    Lynch, P. L. Mark
    O'Kane, Maurice J.
    [J]. JOURNAL OF APPLIED LABORATORY MEDICINE, 2018, 3 (01): : 144 - 145