摘要
Silicon-on-insulator (SOI) substrate is widely used in micro-electro-mechanical systems (MEMS). With the buried oxide layer of SOI acting as an etching stop, silicon based micro neural probe can be fabricated with improved uniformity and manufacturability. A seven-record-site neural probe was formed by inductive-coupled plasma (ICP) dry etching of an SOI substrate. The thickness of the probe is 15 mu m. The shaft of the probe has dimensions of 3 mmx100 mu mx15 mu m with typical area of the record site of 78.5 mu m(2). The impedance of the record site was measured in-vitro. The typical impedance characteristics of the record sites are around 2 M Omega at 1 kHz. The performance of the neural probe in-vivo was tested on anesthetic rat. The recorded neural spike was typically around 140 mu V. Spike from individual site could exceed 700 mu V. The average signal noise ratio was 7 or more.
引用
收藏
页码:1187 / 1190
页数:4
相关论文
共 50 条
  • [1] Multi-channel micro neural probe fabricated with SOI
    WeiHua Pei
    Lin Zhu
    ShuJing Wang
    Kai Guo
    Jun Tang
    Xu Zhang
    Lin Lu
    ShangKai Gao
    HongDa Chen
    [J]. Science in China Series E: Technological Sciences, 2009, 52 : 1187 - 1190
  • [2] Multi-channel micro neural probe fabricated with SOI
    PEI WeiHua1
    2 State Key Laboratory on Integrated Optoelectronics
    [J]. Science China Technological Sciences, 2009, (05) : 1187 - 1190
  • [3] Multi channel micro neural probe fabricated with SOI
    Wang, Shujing
    Pei, Weihua
    Guo, Kai
    Gui, Qiang
    Wang, Yu
    Zhang, Xu
    Tang, Jun
    Chen, Hongda
    [J]. 2009 ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, 2009, : 161 - 164
  • [4] Multi-channel SOI lateral IGBTs with large SOA
    Funaki, H
    Matsudai, T
    Nakagawa, A
    Yasuhara, N
    Yamaguchi, Y
    [J]. ISPSD '97: 1997 IEEE INTERNATIONAL SYMPOSIUM ON POWER SEMICONDUCTOR DEVICES AND ICS, 1997, : 33 - 36
  • [5] Multi-channel Probe for Industrial Ethernet Measurement
    Liu, Zhe
    Huan, Ji
    Nu, Xing
    [J]. FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY II, PTS 1 AND 2, 2012, 503-504 : 1476 - 1479
  • [6] Multi-Channel Graph Neural Networks
    Zhou, Kaixiong
    Song, Qingquan
    Huang, Xiao
    Zha, Daochen
    Zou, Na
    Hu, Xia
    [J]. PROCEEDINGS OF THE TWENTY-NINTH INTERNATIONAL JOINT CONFERENCE ON ARTIFICIAL INTELLIGENCE, 2020, : 1352 - 1358
  • [7] Multi-Channel Neural Network for Steganalysis
    Liu, Kai
    Li, Xuan
    Zhang, Qiong
    Kang, Xiangui
    [J]. 2017 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA ASC 2017), 2017, : 1210 - 1213
  • [8] A multi-channel micro valve for micro pneumatic artificial muscle
    Lee, YK
    Shimoyama, I
    [J]. FIFTEENTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2002, : 702 - 705
  • [9] Author Identification of Micro-Messages via Multi-Channel Convolutional Neural Networks
    Aykent, Sarp
    Dozier, Gerry
    [J]. 2020 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2020, : 675 - 681
  • [10] A high precision analog multiplexer for multi-channel neural recording micro-systems
    Naghavi, Saeed
    Sharifi, Niloofar
    Abrishamifar, Adib
    [J]. MICROELECTRONICS JOURNAL, 2018, 71 : 8 - 18