Development of a theranostic preclinical fluorescence molecular tomography/cone beam CT-guided irradiator platform

被引:4
|
作者
Nouizi, Farouk [1 ,2 ]
Brooks, Jamison [3 ]
Zuro, Darren M. [3 ]
Hui, Susanta K. [3 ]
Gulsen, Gultekin [1 ,2 ]
机构
[1] Univ Calif Irvine, Tu & Yuen Ctr Funct Oncoimaging, Dept Radiol Sci, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Chao Family Comprehens Canc Ctr, Irvine, CA 92697 USA
[3] City Hope Natl Med Ctr, Beckman Res Inst, Dept Radiat Oncol, 1500 E Duarte Rd, Duarte, CA 91010 USA
基金
美国国家卫生研究院;
关键词
DIFFUSE OPTICAL TOMOGRAPHY; BIOLUMINESCENCE TOMOGRAPHY; X-RAY; QUANTITATIVE ACCURACY; RADIATION-THERAPY; RESOLUTION; SYSTEM; PERFORMANCE; LIGHT; MRI;
D O I
10.1364/BOE.469559
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Image-guided small animal radiation research platforms allow more precise radiation treatment. Commercially available small animal X-ray irradiators are often equipped with a CT/cone-beam CT (CBCT) component for target guidance. Besides having poor soft-tissue contrast, CBCT unfortunately cannot provide molecular information due to its low sensitivity. Hence, there are extensive efforts to incorporate a molecular imaging component besides CBCT on these radiation therapy platforms. As an extension of these efforts, here we present a theranostic fluorescence tomography/CBCT-guided irradiator platform that provides both anatomical and molecular guidance, which can overcome the limitations of stand-alone CBCT. The performance of our hybrid system is validated using both tissue-like phantoms and mice ex vivo. Both studies show that fluorescence tomography can provide much more accurate quantitative results when CBCT-derived structural information is used to constrain the inverse problem. The error in the recovered fluorescence absorbance reduces nearly 10-fold for all cases, from approximately 60% down to 6%. This is very significant since high quantitative accuracy in molecular information is crucial to the correct assessment of the changes in tumor microenvironment related to radiation therapy.
引用
收藏
页码:6100 / 6112
页数:13
相关论文
共 50 条
  • [31] Simultaneous Estimation of Beam Geometry and Radiation/Imaging Isocenter Coincidence in Cone-Beam CT-Guided Radiation Therapy
    Ford, J.
    Zheng, D.
    Saleh, H.
    Lu, J.
    Williamson, J.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3152 - +
  • [32] Multidetector CT fluoroscopy and cone-beam CT-guided percutaneous transthoracic biopsy: comparison based on patient doses
    Strocchi, S.
    Colli, V.
    Conte, L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 151 (01) : 162 - 165
  • [33] Planning CT-guided robust and fast cone-beam CT scatter correction using a local filtration technique
    Cui, Hehe
    Jiang, Xiao
    Fang, Chengyijue
    Zhu, Lei
    Yang, Yidong
    [J]. MEDICAL PHYSICS, 2021, 48 (11) : 6832 - 6843
  • [34] Deformable image registration with local rigidity constraints for cone-beam CT-guided spine surgery
    Reaungamornrat, S.
    Wang, A. S.
    Uneri, A.
    Otake, Y.
    Khanna, A. J.
    Siewerdsen, J. H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14): : 3761 - 3787
  • [35] Fluoroscopy and Cone-Beam CT-guided Fixation by Internal Cemented Screw for Pathologic Pelvic Fractures
    Roux, Charles
    Tselikas, Lambros
    Yevich, Steven
    Solha, Raphael Sandes
    Hakime, Antoine
    Teriitehau, Christophe
    Gravel, Guillaume
    de Baere, Thierry
    Deschamps, Frederic
    [J]. RADIOLOGY, 2019, 290 (02) : 418 - 425
  • [36] Chinese expert consensus on cone-beam CT-guided diagnosis, localization and treatment for pulmonary nodules
    Xu, Dongyang
    Xie, Fangfang
    Zhang, Jisong
    Chen, Hong
    Chen, Zhongbo
    Guan, Zhenbiao
    Hou, Gang
    Ji, Cheng
    Li, Haitao
    Li, Manxiang
    Li, Wei
    Li, Xuan
    Li, Yishi
    Lian, Hairong
    Liao, Jiangrong
    Liu, Dan
    Luo, Zhuang
    Ouyang, Haifeng
    Shen, Yongchun
    Shi, Yiwei
    Tang, Chunli
    Wan, Nansheng
    Wang, Tao
    Wang, Hong
    Wang, Huaqi
    Wang, Juan
    Wu, Xuemei
    Xia, Yang
    Xiao, Kui
    Xu, Wujian
    Xu, Fei
    Yang, Huizhen
    Yang, Junyong
    Ye, Taosheng
    Ye, Xianwei
    Yu, Pengfei
    Zhang, Nan
    Zhang, Peng
    Zhang, Quncheng
    Zhao, Qi
    Zheng, Xiaoxuan
    Zou, Jun
    Chen, Enguo
    Sun, Jiayuan
    [J]. THORACIC CANCER, 2024, 15 (07) : 582 - 597
  • [37] Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients
    Létourneau, D
    Martinez, AA
    Lockman, D
    Yan, D
    Vargas, C
    Ivaldi, G
    Wong, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04): : 1239 - 1246
  • [38] The value of Cone-Beam CT-guided radiofrequency ablation in the treatment of pulmonary malignancies (≤3 cm)
    Xiang, Zi-jun
    Wang, Yi
    Du, En-fu
    Xu, Lin
    Jiang, Bin
    Li, Huili
    Wang, Yun
    Cui, Ning
    [J]. BIOSCIENCE REPORTS, 2019, 39
  • [39] Intraoperative cone-beam CT spatial priors for diffuse optical fluorescence tomography
    Daly, M. J.
    Chan, H.
    Muhanna, N.
    Akens, M. K.
    Wilson, B. C.
    Irish, J. C.
    Jaffray, D. A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [40] Development of Integrated Multimodal Molecular Imaging and Xray Irradiator Module for Molecular Image Guided Radiation Therapy (MIGRT) in Preclinical Research
    Papineni, R. V.
    McLaughlin, W.
    Vizard, D.
    Dermott, B.
    Gongalez, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S88 - S88