Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients

被引:151
|
作者
Létourneau, D
Martinez, AA
Lockman, D
Yan, D
Vargas, C
Ivaldi, G
Wong, J
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48072 USA
[2] European Inst Oncol, Dept Radiat Oncol, Milan, Italy
关键词
cone-beam CT; fiducial marker; image-guided therapy; prostate cancer;
D O I
10.1016/j.ijrobp.2005.03.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Kilovoltage cone-beam CT (CBCT) implemented on board a medical accelerator is available for image-guidance applications in our clinic. The objective of this work was to assess the magnitude and stability of the residual setup error associated with CBCT online-guided prostate cancer patient setup. Residual error pertains to the uncertainty in image registration, the limited mechanical accuracy, and the intrafraction motion during imaging and treatment. Methods and Materials: The residual error for CBCT online-guided correction was first determined in a phantom study. After online correction, the phantom residual error was determined by comparing megavoltage portal images acquired every 90 to the corresponding digitally reconstructed radiographs. In the clinical study, 8 prostate cancer patients were implanted with three radiopaque markers made of high-winding coils. After positioning the patient using the skin marks, a CBCT scan was acquired and the setup error determined by fusing the coils on the CBCT and planning CT scans. The patient setup was then corrected by moving the couch accordingly. A second CBCT scan was acquired immediately after the correction to evaluate the residual target setup error. Intrafraction motion was evaluated by tracking the coils and the bony landmarks on kilovoltage radiographs acquired every 30 s between the two CBCT scans. Corrections based on soft-tissue registration were evaluated offline by aligning the prostate contours defined on both planning CT and CBCT images. Results: For ideal rigid phantoms, CBCT image-guided treatment can usually achieve setup accuracy of 1 mm or better. For the patients, after CBCT correction, the target setup error was reduced in almost all cases and was generally within +/- 1.5 mm. The image guidance process took 23-35 min, dictated by the computer speed and network configuration. The contribution of the intrafraction motion to the residual setup error was small, with a standard deviation of +/- 0.9 mm. The average difference between the setup corrections obtained with coil and soft-tissue registration was greatest in the superoinferior direction and was equal to -1.1 +/- 2.9 mm. Conclusion: On the basis of the residual setup error measurements, the margin required after online CBCT correction for the patients enrolled in this study would be approximatively 3 mm and is considered to be a lower limit owing to the small intrafraction motion observed. The discrepancy between setup corrections derived from registration using coils or soft tissue can be due in part to the lack of complete three-dimensional information with the coils or to the difficulty in prostate delineation and requires further study. (c) 2005 Elsevier Inc.
引用
收藏
页码:1239 / 1246
页数:8
相关论文
共 50 条
  • [1] Assessment of residual error for online cone beam CT guided treatment of prostate patients
    Letourneau, D
    Lockman, D
    Yan, D
    Wong, J
    Martinez, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S196 - S197
  • [2] Dosimetric impact of online KV cone-beam CT-guided radiotherapy in prostate cancer
    Chilles, A.
    Ginestet, C.
    Ayadi, M.
    Pommier, P.
    Carrie, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S112 - S112
  • [3] Residual error of the online kilovoltage cone-beam CT guided radiotherapy evaluated in phantom and thoracic cancer patients
    Wang, Y. Y.
    Fu, X. L.
    Yang, H. J.
    Gong, M.
    Wu, Z. Q.
    Jiang, G. L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S499 - S500
  • [4] Cone-Beam CT-Guided Lung Biopsies: Results in 94 Patients
    Gulias-Soidan, Daniel
    Crus-Sanchez, Nilfa Milena
    Fraga-Manteiga, Daniel
    Cao-Gonzalez, Juan Ignacio
    Balboa-Barreiro, Vanesa
    Gonzalez-Martin, Cristina
    [J]. DIAGNOSTICS, 2020, 10 (12)
  • [5] A target containing phantom for accuracy assessment of cone-beam CT-guided histotripsy
    Kutlu, Ayca Z.
    Minesinger, Grace M.
    Laeseke, Paul F.
    Speidel, Michael
    Wagner, Martin G.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (05):
  • [6] The influence of a dietary protocol on cone beam CT-guided radiotherapy for prostate cancer patients
    Smitsmans, Monique H. P.
    Pos, Floris J.
    de Bois, Josien
    Heemsbergen, Wilma D.
    Sonke, Jan-Jakob
    Lebesque, Joos V.
    van Herk, Marcel
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04): : 1279 - 1286
  • [7] Cone-beam CT based image-guided RapidArc treatment of Prostate Cancer
    Hentschel, B.
    Strauss, D.
    Berger, K.
    Dorn, U.
    Oehler, W.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 : 60 - 60
  • [8] Cone-Beam CT-Guided Vertebroplasty in a Patient With Vertebra Plana
    Pua, Uei
    Lim, Gavin Hock Tai
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 196 - 199
  • [9] CONE-BEAM CT-GUIDED STEREOTACTIC RADIOSURGERY FOR SPINAL METASTASES
    Nguyen, Trang K.
    Wolinsky, Jean-Paul
    Sciubba, Daniel M.
    Le, Yi
    Ford, Eric
    Tryggestad, Eric
    Bydon, Ali
    Witham, Timothy F.
    Rigamonti, Daniele
    Wong, John H.
    Gokaslan, Ziya L.
    Kleinberg, Lawrence
    Lim, Michael
    [J]. NEURO-ONCOLOGY, 2009, 11 (05) : 669 - 669
  • [10] A cone beam CT-guided online plan modification technique to correct interfractional anatomic changes for prostate cancer IMRT treatment
    Fu, Weihua
    Yang, Yong
    Yue, Ning J.
    Heron, Dwight E.
    Huq, M. Saiful
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (06): : 1691 - 1703