Gas bubble network formation in irradiated beryllium pebbles monitored by X-ray microtomography

被引:13
|
作者
Moeslang, A. [1 ]
Pieritz, R. A. [2 ]
Boller, E. [2 ]
Ferrero, C. [2 ]
机构
[1] Forschungszentrum Karlsruhe, IMF I, D-76021 Karlsruhe, Germany
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
基金
欧盟地平线“2020”;
关键词
MICROSTRUCTURE; BEDS;
D O I
10.1016/j.jnucmat.2008.12.258
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The effective and safe operation of helium cooled ceramic breeder blankets with beryllium as a neutron multiplier requires among others an efficient tritium release. A micrometric resolution computer aided microtomography (CMT) setup located at the European Synchrotron Radiation Facility made possible the 3D reconstruction of interconnected channel networks of helium bubbles in beryllium pebbles, thus enabling the identification of open porosities in the micrometer range. Beryllium pebbles of 2 mm diameter were neutron irradiated at 770 K to a fluence of 1.24 x 10(25) nm(-2), resulting in 480 appm helium and 12 appm tritium. After annealing at 1500 K, CMT was performed on the pebbles at 4.9 and 1.4 mu m spatial resolution. respectively, followed by the post-processing of the reconstructed pebble volumes. Besides a bimodal pore distribution with a smaller population around 10 mu m diameter and a high density of partly interconnected pores around 40 mu m diameter, a swelling of 17% was found. The spatial distribution of the void fraction network will be discussed together with implications on tritium release behaviour. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1052 / 1055
页数:4
相关论文
共 50 条
  • [21] X-ray fluorescence and X-ray transmission microtomography imaging system
    Pereira, Gabriela R.
    Rocha, Henrique S.
    Anjos, Marcelino J.
    Faria, Paulo
    Perez, Carlos A.
    Lopes, Ricardo T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 128 - 132
  • [22] PROSPECTS OF X-RAY MICROSCOPY AND X-RAY MICROTOMOGRAPHY FOR INTERFACE STUDIES
    ERRE, D
    THOMAS, X
    MOUZE, D
    PATAT, JM
    TREBBIA, P
    CAZAUX, J
    SURFACE AND INTERFACE ANALYSIS, 1992, 19 (1-12) : 89 - 92
  • [23] X-RAY COMPUTED MICROTOMOGRAPHY OF RUBBER
    Jago, Karine Le Gorju
    RUBBER CHEMISTRY AND TECHNOLOGY, 2012, 85 (03): : 387 - 407
  • [24] Desktop X-ray microscopy and microtomography
    Sasov, A
    Van Dyck, D
    JOURNAL OF MICROSCOPY-OXFORD, 1998, 191 : 151 - 158
  • [25] MICROSCOPY X-RAY MICROTOMOGRAPHY IN LABORATORY
    CAZAUX, J
    THOMAS, X
    MOUZE, D
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1989, 14 (04): : 263 - &
  • [26] X-ray microtomography, past and present
    Elliott, J. C.
    Davis, G. R.
    Dover, S. D.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [27] X-ray microtomography of heart tissue
    Phillips, SJ
    Siegler, S
    Stabinski, M
    Goldman, BI
    FASEB JOURNAL, 2004, 18 (04): : A19 - A19
  • [28] X-ray microtomography of bones and teeth
    Davis, GR
    Wong, FSL
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 (03) : 121 - 146
  • [29] X-RAY MICROSCOPY OF BERYLLIUM
    SAWKILL, J
    SCHWARZENBERGER, DR
    BRITISH JOURNAL OF APPLIED PHYSICS, 1960, 11 (11): : 498 - 503
  • [30] Combined imaging system for X-ray fluorescence and transmission X-ray microtomography
    Ohigashi, T
    Watanabe, N
    Yokosuka, H
    Aoki, S
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 1352 - 1355