Implementation and examination of a new drop shape analysis algorithm to measure contact angle and surface tension from the diameters of two sessile drops

被引:11
|
作者
Amirfazli, A
Graham-Eagle, J
Pennell, S
Neumann, AW
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] Univ Massachusetts, Dept Math Sci, Lowell, MA 01854 USA
基金
加拿大自然科学与工程研究理事会;
关键词
sessile drop; contact angle; surface tension; drop shape analysis;
D O I
10.1016/S0927-7757(99)00325-8
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The performance of a new algorithm developed to measure contact angle and surface tension of sessile drops is examined. To calculate the contact angle and surface tension, the new algorithm (ADSA-TD) requires the radius (contact or equatorial) and volume of two sessile drops of different sizes that are placed on the same surface. Initially, the algorithm was tested using synthetic drops (synthetic or theoretical drops are produced by numerical integration of the Laplace equation). The radii and volumes of synthetic drops were used as ADSA-TD inputs. The calculated contact angle (theta) and surface tension (gamma) by ADSA-TD matched perfectly the assumed values of theta and gamma used to produce the synthetic drops, confirming theoretically the validity of the new algorithm. In the next step, the sensitivity of the algorithm to input errors was examined. It was shown experimentally that both calculated contact angle and surface tension are affected by the errors in volume and radius. Besides the error in input values, it was shown that the size difference between the paired drops and the differences in their contact angles would affect the output of ADSA-TD. As it turns out, the calculated surface tension is so sensitive to the above factors that ADSA-TD does not appear to be promising as a surface tension measurement technique. However, ADSA-TD produced acceptable contact angle values as compared to measurements made by other proven techniques such as axisymmetric drop shape analysis-profile. Thus, ADSA-TD may be of interest as a contact angle measurement technique which does not require the liquid surface tension as input. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:63 / 74
页数:12
相关论文
共 45 条
  • [31] An algorithm for selecting the most accurate protocol for contact angle measurement by drop shape analysis
    Xu, Z. N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (12):
  • [32] A non-iterative method to evaluate surface tension and contact angle simultaneously by a sessile drop in gravity using universal figures
    Takahashi K.
    Masumoto N.
    Yosetsu Gakkai Ronbunshu/Quarterly Journal of the Japan Welding Society, 2021, 39 (01): : 32 - 38
  • [33] A non-iterative method to evaluate surface tension and contact angle simultaneously by a sessile drop in gravity using universal figures
    Takahashi K.
    Masumoto N.
    Welding International, 2021, 35 (4-6) : 230 - 239
  • [34] Surface free energy components of aggregates from contact angle measurements using Sessile Drop method
    Koc, M.
    Bulut, R.
    ADVANCES IN TRANSPORTATION GEOTECHNICS II, 2012, : 560 - 565
  • [35] A new methodics of drop edge recognition and its application for surface tension and contact angle measurement
    Boinovich, LB
    Emelyanenko, AM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U644 - U644
  • [36] Sessile Drop Method: Critical Analysis and Optimization for Measuring the Contact Angle of an Ion-Exchange Membrane Surface
    Ponomar, Maria
    Krasnyuk, Ekaterina
    Butylskii, Dmitrii
    Nikonenko, Victor
    Wang, Yaoming
    Jiang, Chenxiao
    Xu, Tongwen
    Pismenskaya, Natalia
    MEMBRANES, 2022, 12 (08)
  • [37] Simultaneous Measurement of Contact Angle and Surface Tension Using Axisymmetric Drop-Shape Analysis-No Apex (ADSA-NA)
    Kalantarian, A.
    David, R.
    Chen, J.
    Neumann, A. W.
    LANGMUIR, 2011, 27 (07) : 3485 - 3495
  • [38] CONTACT ANGLES - WETTING AND DE-WETTING OF MERCURY .1. A CRITICAL EXAMINATION OF SURFACE TENSION MEASUREMENT BY THE SESSILE DROP METHOD
    SMOLDERS, CA
    DUYVIS, EM
    RECUEIL DES TRAVAUX CHIMIQUES DES PAYS-BAS-JOURNAL OF THE ROYAL NETHERLANDS CHEMICAL SOCIETY, 1961, 80 (06): : 635 - &
  • [39] THE INFLUENCE OF DROPLET VOLUME AND CONTACT-ANGLE ON LIQUID SURFACE-TENSION MEASUREMENTS BY AXISYMMETRICAL DROP SHAPE ANALYSIS-PROFILE (ADSA-P)
    NOORDMANS, J
    BUSSCHER, HJ
    COLLOIDS AND SURFACES, 1991, 58 (03): : 239 - 249
  • [40] MEASUREMENT OF CONTACT ANGLES FROM THE MAXIMUM DIAMETER OF NONWETTING DROPS BY MEANS OF A MODIFIED AXISYMMETRICAL DROP SHAPE-ANALYSIS
    MOY, E
    CHENG, P
    POLICOVA, Z
    TREPPO, S
    KWOK, D
    MACK, DR
    SHERMAN, PM
    NEUMANN, AW
    COLLOIDS AND SURFACES, 1991, 58 (03): : 215 - 227