Simultaneous Measurement of Contact Angle and Surface Tension Using Axisymmetric Drop-Shape Analysis-No Apex (ADSA-NA)

被引:38
|
作者
Kalantarian, A. [1 ]
David, R. [1 ]
Chen, J. [1 ]
Neumann, A. W. [1 ]
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
INTERFACIAL-TENSION; RECENT PROGRESS; LIQUID BRIDGES; WETTABILITY; HYSTERESIS; PENDANT; STABILITY;
D O I
10.1021/la104155x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Axisymmetric drop-shape analysis-no apex (ADSA-NA) is a recent drop-shape method that allows the simultaneous measurement of contact angles and surface tensions of drop configurations without an apex (i.e., a sessile drop with a capillary protruding into the drop). Although ADSA-NA significantly enhanced the accuracy of contact angle and surface tension measurements compared to that of original ADSA using a drop with an apex, it is still not as accurate as a surface tension measurement using a pendant drop suspended from a holder. In this article, the computational and experimental aspects of ADSA-NA were scrutinized to improve the accuracy of the simultaneous measurement of surface tensions and contact angles. It was found that the results are relatively insensitive to different optimization methods and edge detectors. The precision of contact angle measurement was enhanced by improving the location of the contact points of the liquid meniscus with the solid substrate to subpixel resolution. To optimize the experimental design, the capillary was replaced with an inverted sharp-edged pedestal, or holder, to control the drop height and to ensure the axisymmetry of the drops. It was shown that the drop height is the most important experimental parameter affecting the accuracy of the surface tension measurement, and larger drop heights yield lower surface tension errors. It is suggested that a minimum nondimensional drop height (drop height divided by capillary length) of 1.7 is required to reach an error of less than 0.2 mJ/m(2) for the measured surface tension. As an example, the surface tension of water was measured to be 72.46 +/- 0.04 at 24 degrees C by ADSA-NA, compared to 72.39 +/- 0.01 mJ/m(2) obtained with pendant drop experiments.
引用
收藏
页码:3485 / 3495
页数:11
相关论文
共 50 条
  • [1] Axisymmetric Drop Shape Analysis (ADSA) for the determination of surface tension and contact angle
    Neumann, A.W. (neumann@mie.utoronto.ca), 1600, Taylor and Francis Ltd. (80):
  • [2] Axisymmetric Drop Shape Analysis (ADSA) for the determination of surface tension and contact angle
    Hoorfar, M
    Neumann, AW
    JOURNAL OF ADHESION, 2004, 80 (08): : 727 - 743
  • [3] Measurement of surface tension and contact angle of solar salt at high temperature with axisymmetric drop-shape analysis
    Detrick, Kent P.
    Staker, Michael
    Schouten, Lydia
    Detrick, John P.
    Seo, Dongjin
    Memmott, Matthew
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2025, 163
  • [4] Evaluation of the surface tension measurement of axisymmetric drop shape analysis (ADSA) using a shape parameter
    Hoorfar, M
    Kurz, MA
    Neumann, AW
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2005, 260 (1-3) : 277 - 285
  • [5] Determination of ultralow interfacial tension by axisymmetric drop-shape analysis
    Kwok, DY
    Chiefalo, P
    Khorshiddoust, B
    Lahooti, S
    CabrerizoVilchez, MA
    delRio, O
    Neumann, AW
    SURFACTANT ADSORPTION AND SURFACE SOLUBILIZATION, 1995, 615 : 374 - 386
  • [6] Improvement of interfacial tension measurement using a captive bubble in conjunction with axisymmetric drop shape analysis (ADSA)
    Zuo, YY
    Ding, M
    Bateni, A
    Hoorfar, M
    Neumann, AW
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2004, 250 (1-3) : 233 - 246
  • [7] A new drop-shape methodology for surface tension measurement
    Cabezas, MG
    Bateni, A
    Montanero, JM
    Neumann, AW
    APPLIED SURFACE SCIENCE, 2004, 238 (1-4) : 480 - 484
  • [8] CONTACT-ANGLE MEASUREMENT BY AXISYMMETRICAL DROP SHAPE-ANALYSIS (ADSA)
    LI, D
    CHENG, P
    NEUMANN, AW
    ADVANCES IN COLLOID AND INTERFACE SCIENCE, 1992, 39 : 347 - 382
  • [9] An Improved Contact Angle Measurement and Simultaneous Measurement of Liquid Surface Tension Using Sessile Drop
    Takahashi K.
    Yosetsu Gakkai Shi/Journal of the Japan Welding Society, 2023, 94 (02): : 246 - 249
  • [10] Tissue surface tension measurement by rigorous axisymmetric drop shape analysis
    David, Robert
    Ninomiya, Hiromasa
    Winklbauer, Rudolf
    Neumann, A. Wilhelm
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 72 (02) : 236 - 240