Expanded theory for the resolving power of a linear ion mobility spectrometer

被引:36
|
作者
Spangler, GE [1 ]
机构
[1] Techispan LLC, Pikesville, MD 21208 USA
关键词
ion mobility spectrometry (IMS); expectation values (drift time); moment analysis (peak width); induced current; collision cross section; theory;
D O I
10.1016/S1387-3806(02)00841-2
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
An expanded theory for the resolving power of a linear ion mobility spectrometer (IMS) is derived. By definition, the resolving power is directly proportional to the total drift time for the ion through the drift tube divided by the full-width-at-half-height (FWHH) of the observed ion mobility peak. Two approaches to theoretically estimating these two parameters are possible, depending on the operating parameters of the IMS cell. The drift time is given by the first moment of the IMS response. If the electric fields (assumed uniform) are equal in both the shutter/aperture and aperture/collector region, the FWHH is given by a difference in error functions. If the electric fields (again assumed uniform) are not equal, the FWHH is given by the second central moment of the IMS response and can only be known to within a multiplicative factor. The effectiveness of these two approaches is demonstrated using IMS data from the published literature. The additional peak broadening often observed in a linear IMS has several possible sources. One depends on the construction of the cell and the parallelism (or lack thereof) that might exist between the aperture grid and ion collector. Another depends on electric fields used to bias the cell. If the electric field in the aperture/collector region is less than in the shutter/aperture region, peak broadening occurs. Induction effects in the aperture/collector region not only shorten drift times, but also create diffusion-like broadening of the peak. Shortening the distance between the aperture grid and ion collector, or using a higher electric field in that region, minimizes induction effects. Drift time calibration requires adjustments for induction effects. (Int J Mass Spectrom 220 (2002) 399-418) (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:399 / 418
页数:20
相关论文
共 50 条
  • [1] Measurements of reduced mobility of standard compounds by high resolving power ion mobility spectrometer in remote laboratories
    D. M. Chernyshev
    I. S. Frolov
    A. S. Frolov
    M. S. Mukhanov
    A. A. Sysoev
    [J]. Journal of Analytical Chemistry, 2011, 66 : 1253 - 1257
  • [2] Measurements of reduced mobility of standard compounds by high resolving power ion mobility spectrometer in remote laboratories
    Chernyshev, D. M.
    Frolov, I. S.
    Frolov, A. S.
    Mukhanov, M. S.
    Sysoev, A. A.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (13) : 1253 - 1257
  • [4] High Resolving Power Electrospray Ionization Ion Mobility Spectrometer Based on Fourier Deconvolution Multiplexing
    Yang, Binwang
    Ye, Zhixiong
    Lu, Feiyu
    Yu, Jianna
    Liu, Jiaxu
    Zheng, Xiuqing
    Wang, Cheng
    Duan, Lian
    Yang, Zhijian
    Jing, Guoxing
    Liu, Wen
    Li, Wenshan
    Liu, Wenjie
    [J]. Analytical Chemistry, 2024, 96 (43) : 17423 - 17431
  • [5] MEASURING THE RESOLVING POWER OF ION MOBILITY SPECTROMETERS
    SIEMS, WF
    WU, C
    TARVER, EE
    HILL, HH
    LARSEN, PR
    MCMINN, DG
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (23) : 4195 - 4201
  • [6] Broadscale resolving power performance of a high precision uniform field ion mobility-mass spectrometer
    May, Jody C.
    Dodds, James N.
    Kurulugama, Ruwan T.
    Stafford, George C.
    Fjeldsted, John C.
    McLean, John A.
    [J]. ANALYST, 2015, 14 (20) : 6824 - 6833
  • [7] Performance, resolving power, and radial ion distributions of a prototype nanoelectrospray ionization resistive glass atmospheric pressure ion mobility spectrometer
    Kwasnik, Mark
    Fuhrer, Katrin
    Gonin, Marc
    Barbeau, Katherine
    Fernandez, Facundo M.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (20) : 7782 - 7791
  • [8] Electrospray Ion Mobility Spectrometer Based on Flexible Printed-Circuit Board Electrodes with Improved Resolving Power
    Boillat, Marc-Aurele
    Rakus, Julian M.
    Hauser, Peter C.
    [J]. ANALYTICAL CHEMISTRY, 2023, 95 (28) : 10777 - 10784
  • [9] Enhanced Resolving Power by Moving Field Ion Mobility Spectrometry
    Bohnhorst, Alexander
    Hitzemann, Moritz
    Lippmann, Martin
    Kirk, Ansgar T.
    Zimmermann, Stefan
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (19) : 12967 - 12974
  • [10] Effect of Space Charge on Resolving Power and Ion Loss in Ion Mobility Spectrometry
    Mariano, Adrian V.
    Su, Wansheng
    Guharay, Samar K.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (09) : 3385 - 3391