Expanded theory for the resolving power of a linear ion mobility spectrometer

被引:36
|
作者
Spangler, GE [1 ]
机构
[1] Techispan LLC, Pikesville, MD 21208 USA
关键词
ion mobility spectrometry (IMS); expectation values (drift time); moment analysis (peak width); induced current; collision cross section; theory;
D O I
10.1016/S1387-3806(02)00841-2
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
An expanded theory for the resolving power of a linear ion mobility spectrometer (IMS) is derived. By definition, the resolving power is directly proportional to the total drift time for the ion through the drift tube divided by the full-width-at-half-height (FWHH) of the observed ion mobility peak. Two approaches to theoretically estimating these two parameters are possible, depending on the operating parameters of the IMS cell. The drift time is given by the first moment of the IMS response. If the electric fields (assumed uniform) are equal in both the shutter/aperture and aperture/collector region, the FWHH is given by a difference in error functions. If the electric fields (again assumed uniform) are not equal, the FWHH is given by the second central moment of the IMS response and can only be known to within a multiplicative factor. The effectiveness of these two approaches is demonstrated using IMS data from the published literature. The additional peak broadening often observed in a linear IMS has several possible sources. One depends on the construction of the cell and the parallelism (or lack thereof) that might exist between the aperture grid and ion collector. Another depends on electric fields used to bias the cell. If the electric field in the aperture/collector region is less than in the shutter/aperture region, peak broadening occurs. Induction effects in the aperture/collector region not only shorten drift times, but also create diffusion-like broadening of the peak. Shortening the distance between the aperture grid and ion collector, or using a higher electric field in that region, minimizes induction effects. Drift time calibration requires adjustments for induction effects. (Int J Mass Spectrom 220 (2002) 399-418) (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:399 / 418
页数:20
相关论文
共 50 条
  • [41] PRECISION LABORATORY MASS SPECTROMETER WITH HIGH RESOLVING POWER
    LEPORSKII, BB
    DESHKEVICH, VL
    KAZAKOV, VI
    ZALETSKII, EI
    VOLGIN, LN
    BEZMATERNYKH, YV
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1969, (06): : 1541 - +
  • [42] THEORETICAL RESOLVING POWER OF A RADIOFREQUENCY MASS SPECTROMETER.
    Coc, A.
    Le Gac, R.
    Simon, M.De Saint
    Thibault, C.
    Touchard, F.
    [J]. Nuclear instruments and methods in physics research, 1988, A271 (03): : 512 - 517
  • [43] VARIATION OF RESOLVING POWER OF A MASS-SPECTROMETER WITH PRESSURE
    GHOSHAL, SN
    DAS, M
    MITRA, NN
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1975, 17 (01): : 67 - 76
  • [44] THEORETICAL RESOLVING POWER OF A RADIOFREQUENCY MASS-SPECTROMETER
    COC, A
    LEGAC, R
    SIMON, MD
    THIBAULT, C
    TOUCHARD, F
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 271 (03): : 512 - 517
  • [45] RESOLVING POWER AND MEASUREMENT OF ISOTOPIC ABUNDANCES BY A TIME-OF-FLIGHT MASS SPECTROMETER WITH A LASER ION SOURCE
    BYKOVSKII, YA
    DYMOVICH, VI
    KOZYREV, YP
    NEVOLIN, VN
    SILNOV, SM
    [J]. SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1971, 15 (11): : 1877 - +
  • [46] Sliding Windows in Ion Mobility (SWIM): A New Approach to Increase the Resolving Power in Trapped Ion Mobility-Mass Spectrometry Hyphenated with Chromatography
    Muller, Hugo B.
    Scholl, Georges
    Far, Johann
    De Pauw, Edwin
    Eppe, Gauthier
    [J]. ANALYTICAL CHEMISTRY, 2023, 95 (48) : 17586 - 17594
  • [47] Application of mobility theory to the interpretation of data generated by linear and RF excited ion mobility spectrometers
    Spangler, GE
    Miller, RA
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 214 (01) : 95 - 104
  • [48] X-ray ion mobility spectrometer
    Pershenkov, VS
    Tremasov, AD
    Belyakov, VV
    Razvalyaev, AU
    Mochkin, VS
    [J]. MICROELECTRONICS RELIABILITY, 2006, 46 (2-4) : 641 - 644
  • [49] Methods for the Self Calibration of Ion Mobility Spectrometer
    Vasilyev, V.
    Pershenkov, V.
    Samotaev, N.
    Belyakov, V.
    Golovin, A.
    Malkin, E.
    Gromov, E.
    Ivanov, I.
    Shaltaeva, Y.
    Lipatov, D.
    [J]. 3RD INTERNATIONAL CONFERENCE ON NANOTECHNOLOGIES AND BIOMEDICAL ENGINEERING, 2016, 55 : 551 - 555
  • [50] SIMPLE ELECTRODE DESIGN FOR ION MOBILITY SPECTROMETER
    CARRICO, JP
    SICKENBERGER, DW
    SPANGLER, GE
    VORA, KN
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (11): : 1058 - 1062