MEASURING THE RESOLVING POWER OF ION MOBILITY SPECTROMETERS

被引:209
|
作者
SIEMS, WF [1 ]
WU, C [1 ]
TARVER, EE [1 ]
HILL, HH [1 ]
LARSEN, PR [1 ]
MCMINN, DG [1 ]
机构
[1] GONZAGA UNIV,DEPT CHEM,SPOKANE,WA 99258
关键词
D O I
10.1021/ac00095a014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion mobility spectrometry peak width data are fitted by a least-squares procedure to a semiempirical model having three adjustable parameters. Peaks are wider than contributions from initial pulse width and diffusion predict, and it is suggested that the additional width is due mainly to electric field inhomogeneity and Coulombic repulsion. The effects of operating conditions and instrument dimensions on resolving power are discussed. It is proposed that increased inhomogeneity of the electric field results in lower measured mobility values, as well as lower resolving power.
引用
收藏
页码:4195 / 4201
页数:7
相关论文
共 50 条
  • [1] How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers
    Thoben, Christian
    Raddatz, Christian-Robert
    Tataroglu, Aykut
    Kobelt, Tim
    Zimmermann, Stefan
    [J]. ANALYTICAL CHEMISTRY, 2023, 95 (21) : 8277 - 8283
  • [2] RESOLVING POWER OF MULTIGRATING SPECTROMETERS
    LINDBLOM, P
    STENMAN, F
    [J]. APPLIED OPTICS, 1989, 28 (13): : 2542 - 2549
  • [3] An analytical model for the optimum drift voltage of drift tube ion mobility spectrometers with respect to resolving power and detection limits
    Kirk, Ansgar T.
    Zimmermann, Stefan
    [J]. INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2015, 18 (3-4) : 129 - 135
  • [4] NOTE ON THE RESOLVING POWER OF MASS SPECTROMETERS
    KERWIN, L
    [J]. CANADIAN JOURNAL OF PHYSICS, 1952, 30 (05) : 503 - 511
  • [5] ON THE MULTIPLE GRATING SPECTROMETERS RESOLVING POWER
    MAZZACURATI, V
    RUOCCO, G
    SIGNORELLI, G
    [J]. OPTICS COMMUNICATIONS, 1988, 67 (06) : 399 - 403
  • [6] THE RESOLVING POWER OF INFRARED PRISM SPECTROMETERS
    MELTZER, RJ
    [J]. ANALYTICAL CHEMISTRY, 1950, 22 (04) : 623 - 623
  • [7] DISPERSION AND RESOLVING POWER OF PRISM SPECTROMETERS
    HAZZARD, GW
    [J]. AMERICAN JOURNAL OF PHYSICS, 1951, 19 (04) : 235 - 236
  • [8] Expanded theory for the resolving power of a linear ion mobility spectrometer
    Spangler, GE
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 220 (03) : 399 - 418
  • [9] Enhanced Resolving Power by Moving Field Ion Mobility Spectrometry
    Bohnhorst, Alexander
    Hitzemann, Moritz
    Lippmann, Martin
    Kirk, Ansgar T.
    Zimmermann, Stefan
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (19) : 12967 - 12974
  • [10] Effect of Space Charge on Resolving Power and Ion Loss in Ion Mobility Spectrometry
    Mariano, Adrian V.
    Su, Wansheng
    Guharay, Samar K.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (09) : 3385 - 3391