MEASURING THE RESOLVING POWER OF ION MOBILITY SPECTROMETERS

被引:209
|
作者
SIEMS, WF [1 ]
WU, C [1 ]
TARVER, EE [1 ]
HILL, HH [1 ]
LARSEN, PR [1 ]
MCMINN, DG [1 ]
机构
[1] GONZAGA UNIV,DEPT CHEM,SPOKANE,WA 99258
关键词
D O I
10.1021/ac00095a014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion mobility spectrometry peak width data are fitted by a least-squares procedure to a semiempirical model having three adjustable parameters. Peaks are wider than contributions from initial pulse width and diffusion predict, and it is suggested that the additional width is due mainly to electric field inhomogeneity and Coulombic repulsion. The effects of operating conditions and instrument dimensions on resolving power are discussed. It is proposed that increased inhomogeneity of the electric field results in lower measured mobility values, as well as lower resolving power.
引用
收藏
页码:4195 / 4201
页数:7
相关论文
共 50 条
  • [41] Nonlinear wavelet compression of ion mobility spectra from ion mobility spectrometers mounted in an unmanned aerial vehicle
    Cao, L
    Harrington, PD
    Harden, CS
    McHugh, VM
    Thomas, MA
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (04) : 1069 - 1077
  • [42] A NEW DESIGN FOR PULSE MAGNETIC MASS-SPECTROMETERS WITH HIGH RESOLVING POWER
    SHUSTROV, BN
    [J]. SOVIET PHYSICS-TECHNICAL PHYSICS, 1961, 5 (07): : 810 - 814
  • [43] EFFECT OF SLIT WIDTH ON RESOLVING POWER OF CYLINDRICAL AND PARALLEL PLANE ELECTROSTATIC SPECTROMETERS
    ROY, D
    DECELLES, M
    CARETTE, JD
    [J]. REVUE DE PHYSIQUE APPLIQUEE, 1971, 6 (01): : 51 - &
  • [44] Methods of ion mobility measuring and their applications
    Karachevtsev, GV
    [J]. USPEKHI KHIMII, 1996, 65 (08) : 712 - 717
  • [45] Broadscale resolving power performance of a high precision uniform field ion mobility-mass spectrometer
    May, Jody C.
    Dodds, James N.
    Kurulugama, Ruwan T.
    Stafford, George C.
    Fjeldsted, John C.
    McLean, John A.
    [J]. ANALYST, 2015, 14 (20) : 6824 - 6833
  • [46] Planar Differential Mobility Analyzer with a Resolving Power of 110
    Amo-Gonzalez, Mario
    Perez, Sergio
    [J]. ANALYTICAL CHEMISTRY, 2018, 90 (11) : 6735 - 6741
  • [47] Performance, resolving power, and radial ion distributions of a prototype nanoelectrospray ionization resistive glass atmospheric pressure ion mobility spectrometer
    Kwasnik, Mark
    Fuhrer, Katrin
    Gonin, Marc
    Barbeau, Katherine
    Fernandez, Facundo M.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (20) : 7782 - 7791
  • [48] Dynamic Time-Warping Correction for Shifts in Ultrahigh Resolving Power Ion Mobility Spectrometry and Structures for Lossless Ion Manipulations
    Hollerbach, Adam L.
    Conant, Christopher R.
    Nagy, Gabe
    Monroe, Matthew E.
    Gupta, Khushboo
    Donor, Micah
    Giberson, Cameron M.
    Garimella, Sandilya V. B.
    Smith, Richard D.
    Ibrahim, Yehia M.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (04) : 996 - 1007
  • [49] Intercomparison of five mobility size spectrometers for measuring atmospheric submicrometer aerosol particles
    Helsper, C.
    Horn, H. -G.
    Schneider, F.
    Wehner, B.
    Wiedensohler, A.
    [J]. GEFAHRSTOFFE REINHALTUNG DER LUFT, 2008, 68 (11-12): : 475 - 481
  • [50] Increasing the resolution of ion mobility increment spectrometers using the ripple voltage
    Pervukhin, V. V.
    Sheven, D. G.
    [J]. TECHNICAL PHYSICS LETTERS, 2008, 34 (11) : 977 - 980