Comparative Evaluation of Foveal Avascular Zone on Two Optical Coherence Tomography Angiography Devices

被引:10
|
作者
Dave, Prachi A. [1 ]
Dansingani, Kunal K. [2 ]
Jabeen, Ayesha [3 ]
Jabeen, Asiya [3 ]
Ali, M. Hasnat [3 ]
Vupparaboina, Kiran Kumar [3 ]
Peguda, Hari Kumar [3 ]
Pappurru, Rajeev Reddy [3 ]
Agrawal, Rupesh [4 ]
Chhablani, Jay [3 ]
机构
[1] Dr Shroffs Char Eye Hosp, New Delhi, India
[2] Univ Nebraska Med Ctr, Truhlsen Eye Inst, Omaha, NE USA
[3] Srimati Kanuri Santhamma Ctr Vitreo Retinal Dis, LV Prasad Eye Inst, KAR Campus, Hyderabad, Telangana, India
[4] Tan Tock Seng Hosp, Natl Healthcare Grp, Eye Inst, Singapore, Singapore
关键词
DIABETIC-RETINOPATHY; QUANTIFICATION; AREA;
D O I
10.1097/OPX.0000000000001238
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE: This study compares foveal avascular zone (FAZ) geometry in healthy eyes as imaged by two commercially available optical coherence tomography angiography (OCTA) devices. Foveal avascular zone measurements are repeatable and reproducible with each OCTA device, but interdevice agreement was poor. We provide conversion factors between devices. PURPOSE: The purpose of this study was to perform comparative evaluation of FAZ geometry in healthy eyes as imaged by two commercially available OCTA devices. METHODS: Ninety-six eyes of 48 healthy subjects were imaged prospectively on each of two OCTA devices (DRI-OCT [Topcon Corporation, Tokyo, Japan]; Cirrus 5000 [Carl Zeiss Meditec Inc., Dublin, CA]). The FAZ was evaluated in the superficial capillary plexus layer of 6 x 6-mm foveal scans by two masked observers. Intraobserver and interobserver agreement was determined using intraclass correlation by using linear mixed models and Bland-Altman plots. K-means clustering was used to provide conversion values between two devices. Foveal avascular zone acircularity was calculated using scans from each device and compared. RESULTS: The intraobserver repeatability for DRI-OCT was 0.95 (95% confidence interval [CI], 0.90 to 0.98) for observer A and 0.92 (95% CI, 0.83 to 0.96) for observer B. Intraobserver repeatability for Cirrus 5000 was 0.988 (95% CI, 0.972 to 0.995) for observer A and 0.993 (95% CI, 0.983 to 0.997) for observer B. The interobserver variability between observers A and B for DRI-OCT was 0.87 (0.73 to 0.94) and for Cirrus 5000 was 0.984 (95% CI, 0.964 to 0.993). Poor interdevice agreement (0.205 [95% CI, -0.202 to 0.554]) was noted, and conversion formulas were devised to convert FAZ area measurements from one device to another. No significant correlation was found when comparing FAZ acircularity indices between devices (P = .39). CONCLUSIONS: Repeatable and reproducible FAZ area measurements were obtained with each respective OCTA device, but interdevice agreement was poor, yet quantifiable and systematic with calculable conversion factors between devices.
引用
收藏
页码:602 / 607
页数:6
相关论文
共 50 条
  • [41] Evaluation of macular microvasculature and foveal avascular zone in patients with retinal vein occlusion using optical coherence tomography angiography
    Fan, Lingling
    Zhu, Yazhou
    Liao, Rongfeng
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (01) : 211 - 218
  • [42] Reproducibility of Vessel Density, Fractal Dimension, and Foveal Avascular Zone Using 7 Different Optical Coherence Tomography Angiography Devices
    Sacconi, Riccardo
    Borrelli, Enrico
    Querques, Giuseppe
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 192 : 252 - 253
  • [43] Evaluation of foveal avascular zone in diabetic patients with or without macular edema by swept source optical coherence tomography angiography
    Ham, Don-Il
    Kim, Sung Min
    Kong, Mingui
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [44] Evaluation of macular microvasculature and foveal avascular zone in patients with retinal vein occlusion using optical coherence tomography angiography
    Lingling Fan
    Yazhou Zhu
    Rongfeng Liao
    International Ophthalmology, 2022, 42 : 211 - 218
  • [45] Reproducibility of Vessel Density, Fractal Dimension, and Foveal Avascular Zone Using 7 Different Optical Coherence Tomography Angiography Devices
    Corvi, Federico
    Pellegrini, Marco
    Erba, Stefano
    Cozzi, Mariano
    Staurenghi, Giovanni
    Giani, Andrea
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 186 : 25 - 31
  • [46] Superficial and Deep Foveal Avascular Zone Area Measurement in Healthy Subjects Using Two Different Spectral Domain Optical Coherence Tomography Angiography Devices
    Anvari, Pasha
    Najafi, Amin
    Mirshahi, Reza
    Sardarinia, Mahsa
    Ashrafkhorasani, Maryam
    Kazemi, Pegah
    Aghai, Gholamhoseyn
    Habibi, Abbas
    Falavarjani, Khalil Ghasemi
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2020, 15 (04) : 517 - 523
  • [47] Investigations of Foveal Avascular Zone by Optical Coherence Tomography Angiography before and after Macular Hole Surgery
    Kakisu, Masato
    Baba, Takayuki
    Nizawa, Tomohiro
    Oshitari, Toshiyuki
    Yamamoto, Shuichi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [48] Automatic quantification of superficial foveal avascular zone in optical coherence tomography angiography implemented with deep learning
    Guo, Menglin
    Zhao, Mei
    Cheong, Allen M. Y.
    Dai, Houjiao
    Lam, Andrew K. C.
    Zhou, Yongjin
    VISUAL COMPUTING FOR INDUSTRY BIOMEDICINE AND ART, 2019, 2 (01)
  • [49] Foveal avascular zone segmentation in optical coherence tomography angiography images using a deep learning approach
    Mirshahi, Reza
    Anvari, Pasha
    Riazi-Esfahani, Hamid
    Sardarinia, Mahsa
    Naseripour, Masood
    Falavarjani, Khalil Ghasemi
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [50] A morphological study of the foveal avascular zone in patients with diabetes mellitus using optical coherence tomography angiography
    Gong Di
    Yu Weihong
    Zhang Xiao
    Yang Zhikun
    Zou Xuan
    Qu Yi
    Dong Fangtian
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 873 - 879