Age dependency of sensing performance and AV synchrony in single lead VDD pacing

被引:17
|
作者
Wiegand, UKH [1 ]
Potratz, J [1 ]
Bode, F [1 ]
Schneider, R [1 ]
Peters, W [1 ]
Bonnemeier, H [1 ]
Katus, HA [1 ]
机构
[1] Med Univ Lubeck, Med Klin 2, Dept Internal Med 2, D-23538 Lubeck, Germany
来源
关键词
single lead VDD pacemaker; age; atrial sensing; sinus node function; atrial fibrillation; AV synchrony;
D O I
10.1111/j.1540-8159.2000.tb00856.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implantation of single lead VDD pacemakers is an established therapeutic option in patients with AV block and normal sinus node function. However, related to occurrence of sinus node disease and atrial undersensing, there is concern whether VDD devices are appropriate in physically active young patients. Two hundred thirty-two consecutive patients with isolated AV block and VDD pacemakers were investigated. This population was subdivided into quartiles of 58 patients according to age at time of inclusion: 26.2-59.4 years (group A), 59.5-70.1 years (group B), 70.2-81.0 years (group C), and 81.1-92.5 years (group D). Follow-up visits included pacemaker telemetry, Holter monitoring, and exercise testing. Patients were visited at 2 and 12 weeks after implantation thereafter followed by 6-month intervals. Mean follow-up period was 35 +/- 14 months. Three months after implantation, atrial sensing threshold was significantly higher in young patients: 1.18 +/- 0.58 mV (group A) versus 0.79 +/- 0.35 mV (group B), 0.68 +/- 0.33 mV(group C), and 0.60 +/- 0.25 mV (group D), P < 0.001 for comparison of group A to all other groups. Atrial undersensing was observed less frequently in young patients: 6.9% (group A) versus 17.2 % (group B), 24.1 % (group C), and 27.6% (group D), P = 0.025 for intergroup comparisons. Sinus node dysfunction did not occur in group A. Atrial arrhythmias and loss of AV synchronized pacing mode occurred rarely in young patients: 0.6% (0.4%) per year in group A versus 1.3% (1.3%) in group B, 3.9% (3.4%) in group C, and 5.7% (7.4%) per year in group D, P < 0.01 for intergroup comparisons. Our data show good atrial sensing performance, low incidence of sinus node dysfunction, and few atrial arrhythmias in young patients with VDD pacing for AV block. Thus, single lead VDD pacing can be recommended particularly for young patients with AV block.
引用
收藏
页码:863 / 869
页数:7
相关论文
共 50 条
  • [21] Dual chamber pacing with a single lead VDD pacing system
    Rey, JL
    PACEMAKER LEADS 1997, 1997, : 169 - 172
  • [22] Usefulness of echocardiography to predict inappropriate atrial sensing in single-lead VDD pacing
    De Cock, CC
    Van Campen, LC
    Huygens, J
    Kamp, O
    Visser, CA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (09): : 1344 - 1347
  • [23] Feasibility and sensing thresholds of temporary single-lead VDD pacing in intensive care
    Voigtlander, T
    Nowak, B
    Barenfanger, P
    Himmrich, E
    Treese, N
    Becker, HJ
    Meyer, J
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (10): : 1360 - 1363
  • [24] SINGLE-LEAD VDD PACING - EXCELLENCE OR EXPEDIENCE
    KATRITSIS, D
    CAMM, AJ
    CLINICAL CARDIOLOGY, 1991, 14 (11) : 917 - 922
  • [25] Single lead atrial synchronised ventricular (VDD) pacing
    Crick, JCP
    PRACTICE AND PROGRESS IN CARDIAC PACING AND ELECTROPHYSIOLOGY, 1996, : 119 - 125
  • [26] Single pass lead VDD pacing in children and adolescents
    Rosenheck, S
    Elami, A
    Amikam, S
    Erdman, S
    Ovsyshcher, IE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (08): : 1961 - 1966
  • [27] VDD PACING WITH A PREVIOUSLY IMPLANTED SINGLE LEAD SYSTEM
    NAKATA, Y
    OGURA, S
    TOKANO, T
    YASUDA, M
    OHNO, Y
    HISAOKA, T
    SUMIYOSHI, M
    NAKAZATO, Y
    YAMAGUCHI, H
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (10): : 1425 - 1429
  • [28] Safety and effectiveness of single-lead VDD pacing
    Chabbar Boudet, Maruan C.
    Lukic, Antonella
    Galache Osuna, Jose G.
    de Juan Montiel, Jesus
    Cay Diarte, Eduardo
    Diarte de Miguel, Jose A.
    Peralta, Luis J. Placer
    REVISTA ESPANOLA DE CARDIOLOGIA, 2006, 59 (09): : 897 - 904
  • [29] Single lead VDD pacemaker: atrial sensing performance and treadmill test
    Guyomar, Y
    Graux, P
    Moulin, C
    Carlioz, R
    Dutoit, A
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 763 - 767
  • [30] How reliable is atrial sensing in single-lead VDD pacing:: Comparison of three systems
    Nowak, B
    Middeldorf, T
    Voigtländer, T
    Rosocha, S
    Liebrich, A
    Zellerhoff, C
    Przibille, O
    Himmrich, E
    Meyer, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11): : 2226 - 2231