A prospective randomised comparison of two insertion methods for i-gel placement in anaesthetised paralysed patients: standard vs rotational technique

被引:19
|
作者
Kim, H. C. [1 ]
Yoo, D. H. [1 ]
Kim, H. J. [1 ]
Jeon, Y. T. [2 ]
Hwang, J. W. [2 ]
Park, H. P. [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Seoul Natl Univ Hosp, Dept Anaesthesiol & Pain Med, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Bundang Hosp, Dept Anaesthesiol & Pain Med, Songnam, South Korea
关键词
LARYNGEAL MASK AIRWAY; SUPRAGLOTTIC AIRWAY; CARDIOPULMONARY-RESUSCITATION; LMA-UNIQUE; I-GEL(TM); TRIAL; INTUBATION; CROSSOVER; SURGERY;
D O I
10.1111/anae.12680
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In this prospective randomised study, we compared two techniques for i-gel insertion. One hundred and eighty-one anaesthetised, paralysed adult patients were randomly allocated into one of two groups. In the standard group (n=91), the i-gel was inserted using the standard technique. In the rotation group (n=90), the i-gel was rotated 90 degrees anticlockwise in the mouth and re-rotated in the hypopharynx to the original alignment. The success rate, insertion time, air leak pressure and complications were assessed. The success rate for insertion at the first attempt was lower for the standard technique, 78 (86%) vs 87 (97%; p=0.016). The mean (SD) insertion time was longer (26.9 (14.5) s vs 22.4 (10.2)s; p=0.016) and air leak pressure was lower (22.5 (10.4) cmH2O vs 27.1 (9.4)cmH2O; p=0.002) in the standard group. The incidence of bloodstaining was higher with the standard technique (8 (9%) vs 1 (1%); p=0.034). This study suggests that the rotational technique is superior to the standard technique for i-gel insertion.
引用
收藏
页码:729 / 734
页数:6
相关论文
共 50 条
  • [31] COMPARISON OF HAEMODYNAMIC EFFECTS AND EASE OF I-GEL INSERTION WITH DEXMEDETOMIDINE-PROPOFOL VS. FENTANYL-PROPOFOL
    Dabas, Priyanka
    Rasquinha, Jitesh M.
    Puttige, Keerthi
    Dubey, Ashirwad
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (102): : 7450 - 7454
  • [32] End-tidal concentration of Sevoflurane for removal of Proseal-laryngeal mask airway versus I-gel in Anaesthetised adults - A prospective Randomised clinical study
    Rajendran, Shanthi Sharmiya
    Patel, Mamta G.
    Upadhyay, M. R. Upadhyay
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 229 - 229
  • [33] Comparison of malposition of i-gel in pediatric patients after blind and CMAC guided insertion - A randomized controlled trial
    Kumar, Rakesh
    Bihani, Pooja
    Syal, Rashmi
    Mohammed, Sadik
    Chhabra, Swati
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 1250 - 1250
  • [34] Comparison of Baska mask airway and i-gel for ease of insertion and hemodynamic stability in patients undergoing general anesthesia
    Gupta, Ankita
    Rastogi, Kapil
    Khan, Aamir Laique
    Pathak, Amitesh
    Shahid, Razi
    ANAESTHESIA PAIN & INTENSIVE CARE, 2025, 29 (01) : 70 - 76
  • [35] The effects of two-handed jaw thrust on i-gel™ placement in anesthetized non-paralyzed patients
    Huh, Hyub
    Cho, Jang E.
    Lee, Suk W.
    Kim, Hyun-Chang
    MINERVA ANESTESIOLOGICA, 2021, 87 (10) : 1109 - 1116
  • [36] A RANDOMISED CONTROLLED STUDY OF COMPARISON OF INTRAOCULAR PRESSURE AND HAEMODYNAMIC RESPONSES TO INSERTION OF THE I-GEL, CLASSICAL LARYNGEAL MASK AIRWAY AND ENDOTRACHEAL TUBE
    Khot, Aditya
    Jamale, P. B.
    Dhulkhed, V. K.
    Naik, Shraddha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (41): : 2614 - 2619
  • [37] Comparison of Clinical Performance of C-MAC Video Laryngoscope Guided vs Blind Placement of I-Gel® in Paediatric Patients: A Randomized Controlled OpenLabel Trial
    Kumar, Rakesh
    Bihani, Pooja
    Mohammed, Sadik
    Syal, Rashmi
    Bhatia, Pradeep
    Jaju, Rishabh
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2023, 51 (04) : 347 - 353
  • [38] Assessment of awake i-gel (TM) insertion for fiberoptic-guided intubation in patients with predicted difficult airway: A prospective, observational study
    Arevalo Ludena, Julian
    Arcas Bellas, Jose Juan
    Alvarez Rementeria, Rafael
    Munoz Alameda, Luis Enrique
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2018, 34 (04) : 490 - 495
  • [39] Does prewarming the i-gel supraglottic airway device fit the larynx better compared to keeping it at room temperature for non-paralysed, sedated patients: a randomised controlled trial
    Komasawa, Nobuyasu
    Nishihara, Isao
    Tatsumi, Shinichi
    Minami, Toshiaki
    BMJ OPEN, 2015, 5 (01):
  • [40] Comparison of the i-gel (TM) and the LMA ProsealTM in anesthetized patients undergoing laparoscopic cholecystectomy: a prospective, randomized clinical trial
    Belena, Jose M.
    Nunez, Monica
    Vidal, Alfonso
    Gasco, Carmen
    Yuste, Javier
    Kahn, Amjad
    ANAESTHESIA PAIN & INTENSIVE CARE, 2015, 19 (02) : 135 - 140