Comparison of Clinical Performance of C-MAC Video Laryngoscope Guided vs Blind Placement of I-Gel® in Paediatric Patients: A Randomized Controlled OpenLabel Trial

被引:0
|
作者
Kumar, Rakesh [1 ]
Bihani, Pooja [2 ]
Mohammed, Sadik [1 ]
Syal, Rashmi [2 ]
Bhatia, Pradeep [1 ]
Jaju, Rishabh [3 ]
机构
[1] All India Inst Med Sci AIIMS, Dept Anaesthesiol, Jodhpur, Rajasthan, India
[2] Dr Sampurnanand Med Coll, Dept Anaesthesiol, Jodhpur, Rajasthan, India
[3] All India Inst Med Sci AIIMS, Dept Anaesthesiol, Deoghar, India
关键词
Bronchoscope; children; functional performance; general anaesthesia; supraglottic airway device; SUPRAGLOTTIC AIRWAY DEVICES; FIBEROPTIC ASSESSMENT; INSERTION; ANESTHETISTS; GUIDELINES; MANAGEMENT; SOCIETY;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Placement of the supraglottic airway devices under direct vision has been shown to decrease the incidence of malposition in adults. This study was designed to compare the clinical performance of C-MAC guided and blind placement of i-gel (R) in paediatric patients. Methods: The present prospective, randomized controlled study was conducted on 102 paediatric patients scheduled to undergo elective infraumbilical surgeries under general anaesthesia. Patients were randomly divided into group "B" (blind) and group "C" (C-MAC) based on the technique used for placement of i-gel (R). The primary objective of the study was to compare the incidence of malposition based on the fiberoptic bronchoscope (FOB) score of the glottic view. Oropharyngeal leak pressure (OPLP), hemodynamic parameters, and insertion characteristics (time taken to insert and the number of attempts) were secondary objectives. Categorical data were presented as ratio or percentage and continuous data were presented as mean +/- standard deviation or median [95% confidence interval (CI)]. Results: The incidence of malposition (Brimacombe score 1 or 2) was significantly lower in group C compared to group B (7.8% vs 49% respectively) (P < 0.001); implying a relative risk reduction of 2.42 (95% CI 1.72 to 3.40) with C-MAC. On FOB assessment, the median (interquartile range) Brimacombe score was significantly better in group C [4 (4-4)] compared to group B [3 (2-3)] (P < 0.001). The OPLP was significantly higher in group C compared to group B. Other insertion characteristics were comparable in both the study groups. Conclusion: Compared to blind placement, C-MAC guided placement ensures proper alignment of i-gel (R) with periglottic structures and proper functioning of i-gel (R)
引用
收藏
页码:347 / 353
页数:7
相关论文
共 49 条
  • [1] Comparison of Clinical Performance of C-MAC Video Laryngoscope Guided vs Blind Placement of I-Gel® in Paediatric Patients: A Randomized Controlled Open-Label Trial
    Kumar, Rakesh
    Bihani, Pooja
    Mohammed, Sadik
    Syal, Rashmi
    Bhatia, Pradeep
    Jaju, Rishabh
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2022, 51 (04) : 347 - 353
  • [2] Clinical evaluation of C-Mac D-Blade video laryngoscope: randomized comparison with C-Mac Blade and direct laryngoscopy
    Hostic, V.
    Maldini, B.
    Novotny, Z.
    Hodzovic, I.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (06) : E905 - E906
  • [3] Comparison of conventional C-MAC video laryngoscope guided intubation by anesthesia trainees with and without Frova endotracheal introducer: A randomized clinical trial
    Arasu, Meenupriya
    Rudingwa, Priya
    Satyaprakash, Mv S.
    Panneerselvam, Sakthirajan
    Kuberan, Aswini
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2020, 36 (04) : 483 - 488
  • [4] Comparison of malposition of i-gel in pediatric patients after blind and CMAC guided insertion - A randomized controlled trial
    Kumar, Rakesh
    Bihani, Pooja
    Syal, Rashmi
    Mohammed, Sadik
    Chhabra, Swati
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 1250 - 1250
  • [5] Comparison of the C-MAC D-Blade videolaryngoscope and direct laryngoscope in pediatric patients: Randomized controlled trial
    Hajiyeva, Konul
    Can, Ozlem Selvi
    Baytas, Volkan
    Guclu, Cigdem Yildirim
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2021, 27 (04): : 421 - 426
  • [6] Bougie-assisted C-MAC video laryngoscope versus C-MAC video stylet for awake endoscopic intubation in anticipated difficult airways: A randomized controlled trial
    Falcetta, S.
    Borioni, M.
    Montozzi, A.
    Carsetti, A.
    Sorbello, M.
    Cataldo, R.
    Di Giacinto, I.
    Cerutti, E.
    Donati, A.
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2023, 50
  • [7] Learning curve and performance in simulated difficult airway for the novel C-MAC® video-stylet and C-MAC® Macintosh video laryngoscope: A prospective randomized manikin trial
    Pius, James
    Noppens, Ruediger R.
    PLOS ONE, 2020, 15 (11):
  • [8] Comparison of aerosol box intubation with C-MAC video laryngoscope and direct laryngoscopy-A randomised controlled trial
    Puthenveettil, Nitu
    Rahman, Sajan
    Vijayaraghavan, Sundeep
    Suresh, Sneha
    Kadapamannil, Dilesh
    Paul, Jerry
    INDIAN JOURNAL OF ANAESTHESIA, 2021, 65 (02) : 133 - 138
  • [9] The C-MAC video laryngoscope helps presbyopic anesthetists to overcome difficulty in neonatal and infantile intubation: a randomized controlled trial
    Abdalla, Ashraf E.
    Eissa, Mohsen M.
    Elbasyouny, Mohamed R.
    Zomra, Mahmoud R.
    Elnaggar, Ahmed M.
    Elsayed, Mahmoud M.
    BMC ANESTHESIOLOGY, 2025, 25 (01):
  • [10] Comparing the effectiveness of c-mac video laryngoscope™ and reverse sellick's techniques to the blind method for nasogastric tube insertion in anesthetized, intubated patients: A randomized controlled trial
    Karthik, Nikhil
    Satish, Aparna
    Sushma, H.
    Vellanki, Susmitha
    Tom, Mathew
    Kulkarni, Malavika
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2024, 59