Agreement Between Methods of Measurement of Mean Aortic Wall Thickness by MRI

被引:21
|
作者
Rosero, Eric B. [1 ]
Peshock, Ronald M. [2 ,3 ]
Khera, Amit [3 ]
Clagett, G. Patrick [1 ]
Lo, Hao [2 ]
Timaran, Carlos [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Surg, Div Vasc & Endovasc Surg, Dallas, TX 75390 USA
[2] Univ Texas SW Med Ctr Dallas, Dept Radiol, Donald W Reynolds Cardiovasc Clin Res Ctr, Dallas, TX 75390 USA
[3] Univ Texas SW Med Ctr Dallas, Dept Internal Med, Donald W Reynolds Cardiovasc Clin Res Ctr, Dallas, TX 75390 USA
关键词
wall thickness; cardiovascular MRI; atherosclerosis; HUMAN ATHEROSCLEROTIC LESIONS; INTIMA-MEDIA THICKNESS; MAGNETIC-RESONANCE; HIGH-RESOLUTION; CAROTID-ARTERY; PLAQUE; REPRODUCIBILITY; SIMVASTATIN; STATISTICS; REGRESSION;
D O I
10.1002/jmri.21697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the agreement between three methods of calculation of mean aortic wall thickness (MAWT) using magnetic resonance imaging (MRI). Materials and Methods: High-resolution MRI of the infra-renal abdominal aorta was performed on 70 subjects with a history of coronary artery disease who were part of a multi-ethnic population-based sample. MAWT was calculated as the mean distance between the adventitial and luminal aortic boundaries using three different methods: average distance at four standard positions (AWT-4P). average distance at 100 automated positions (AWT-100P), and using a mathematical computation derived from the total vessel and luminal areas (AWT-VA). Bland-Altman plots and Passing-Bablok regression analyses were used to assess agreement between methods. Results: Bland-Altman analyses demonstrated a positive bias of 3.02 +/- 7.31% between the AWT-VA and the AWT-4P methods, and of 1.76 +/- 6.82% between the WT-100P and the AWT-4P methods. Passing-Bablok regression analyses demonstrated constant bias between the AWT-4P method and the other two methods. Proportional bias was, however, not evident among the three methods. Conclusion: MRI methods of measurement of MAWT using a limited number of positions of the aortic wall systematically underestimate the MAWT value compared with the method that calculates MAWT from the vessel areas.
引用
收藏
页码:576 / 582
页数:7
相关论文
共 50 条
  • [31] Novel MRI Technique Enables Non-Invasive Measurement of Atrial Wall Thickness
    Varela, Marta
    Morgan, Ross
    Theron, Adeline
    Dillon-Murphy, Desmond
    Chubb, Henry
    Whitaker, John
    Henningsson, Markus
    Aljabar, Paul
    Schaeffter, Tobias
    Kolbitsch, Christoph
    Aslanidi, Oleg V.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (08) : 1607 - 1614
  • [32] Improvement in Aortic Vascular Inflammation by 18-FDG PET/CT Associates With Reduction in Aortic Wall Thickness by MRI
    Kabbany, Mohammad T.
    Dey, Amit K.
    Shukla, Parag
    Chaturvedi, Abhishek
    Lerman, Joseph B.
    Aberra, Tsion M.
    Joshi, Aditya A.
    Silverman, Joanna I.
    Ng, Qimin
    Teague, Heather L.
    Dahiya, Asha
    Rodante, Justin A.
    Ahlman, Mark A.
    Playford, Martin P.
    Mehta, Nehal N.
    CIRCULATION, 2016, 134
  • [34] Agreement between methods
    van Stralen, Karlijn J.
    Jager, Kitty J.
    Zoccali, Carmine
    Dekker, Friedo W.
    KIDNEY INTERNATIONAL, 2008, 74 (09) : 1116 - 1120
  • [35] Wall Thickness Measurement of Pipes Using Digital Radiography and Three Wavelet Methods
    Zeinab Kiapasha
    Effat Yahaghi
    Mahdi Mirzapour
    Sajjad Monem
    Jahangir Nekoei
    Journal of Nondestructive Evaluation, 2020, 39
  • [36] Wall Thickness Measurement of Pipes Using Digital Radiography and Three Wavelet Methods
    Kiapasha, Zeinab
    Yahaghi, Effat
    Mirzapour, Mahdi
    Monem, Sajjad
    Nekoei, Jahangir
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2020, 39 (01)
  • [38] Measurement of the thickness of the liquid microlayer between a sliding bubble and a heated wall
    Li, Xin
    Hollingsworth, D. Keith
    Witte, Larry C.
    HT2005: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2005, VOL 2, 2005, : 431 - 441
  • [39] AGREEMENT BETWEEN 2 DIETARY METHODS IN THE MEASUREMENT OF ALCOHOL-CONSUMPTION
    FLEGAL, KM
    JOURNAL OF STUDIES ON ALCOHOL, 1990, 51 (05): : 408 - 414
  • [40] Median nerve latency measurement agreement between portable and conventional methods
    Atroshi, I
    Gummesson, C
    Johnsson, R
    Ornstein, E
    Rosén, I
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (01): : 73 - 77