Agreement Between Methods of Measurement of Mean Aortic Wall Thickness by MRI

被引:21
|
作者
Rosero, Eric B. [1 ]
Peshock, Ronald M. [2 ,3 ]
Khera, Amit [3 ]
Clagett, G. Patrick [1 ]
Lo, Hao [2 ]
Timaran, Carlos [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Surg, Div Vasc & Endovasc Surg, Dallas, TX 75390 USA
[2] Univ Texas SW Med Ctr Dallas, Dept Radiol, Donald W Reynolds Cardiovasc Clin Res Ctr, Dallas, TX 75390 USA
[3] Univ Texas SW Med Ctr Dallas, Dept Internal Med, Donald W Reynolds Cardiovasc Clin Res Ctr, Dallas, TX 75390 USA
关键词
wall thickness; cardiovascular MRI; atherosclerosis; HUMAN ATHEROSCLEROTIC LESIONS; INTIMA-MEDIA THICKNESS; MAGNETIC-RESONANCE; HIGH-RESOLUTION; CAROTID-ARTERY; PLAQUE; REPRODUCIBILITY; SIMVASTATIN; STATISTICS; REGRESSION;
D O I
10.1002/jmri.21697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the agreement between three methods of calculation of mean aortic wall thickness (MAWT) using magnetic resonance imaging (MRI). Materials and Methods: High-resolution MRI of the infra-renal abdominal aorta was performed on 70 subjects with a history of coronary artery disease who were part of a multi-ethnic population-based sample. MAWT was calculated as the mean distance between the adventitial and luminal aortic boundaries using three different methods: average distance at four standard positions (AWT-4P). average distance at 100 automated positions (AWT-100P), and using a mathematical computation derived from the total vessel and luminal areas (AWT-VA). Bland-Altman plots and Passing-Bablok regression analyses were used to assess agreement between methods. Results: Bland-Altman analyses demonstrated a positive bias of 3.02 +/- 7.31% between the AWT-VA and the AWT-4P methods, and of 1.76 +/- 6.82% between the WT-100P and the AWT-4P methods. Passing-Bablok regression analyses demonstrated constant bias between the AWT-4P method and the other two methods. Proportional bias was, however, not evident among the three methods. Conclusion: MRI methods of measurement of MAWT using a limited number of positions of the aortic wall systematically underestimate the MAWT value compared with the method that calculates MAWT from the vessel areas.
引用
收藏
页码:576 / 582
页数:7
相关论文
共 50 条
  • [21] NONDESTRUCTIVE MEASUREMENT OF WALL THICKNESS
    ROSENBERG, R
    KUNSTSTOFFE-GERMAN PLASTICS, 1991, 81 (03): : 237 - 239
  • [22] WALL AND BAND THICKNESS MEASUREMENT
    JUNKE, H
    CHEMISCHE TECHNIK, 1972, 24 (10): : 650 - &
  • [23] Wall thickness measurement and control
    Koetter, Wilfried
    Pielsticker, Bernd
    Wireworld, 1994, 36 (02):
  • [24] WALL THICKNESS MEASUREMENT BY ULTRASONICS
    BROOKE, C
    ANTI-CORROSION METHODS AND MATERIALS, 1978, 25 (06) : 8 - 10
  • [25] Multimodal optical measurement in vitro of surface deformations and wall thickness of the pressurized aortic arch
    Genovese, Katia
    Humphrey, Jay D.
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (04)
  • [26] How to evaluate the vascular consequences of hypertension:: Measurement of carotid wall thickness or aortic stiffness?
    Baguet, JP
    Mounier-Véhier, C
    Moreau-Gaudry, A
    Bouvaist, H
    Mallion, JM
    JOURNAL OF HYPERTENSION, 2002, 20 : S344 - S344
  • [27] MEASUREMENT OF THORACIC AORTIC-WALL THICKNESS BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY - AN IN-VITRO VALIDATION
    SLAMA, MA
    FORNES, P
    HEUDES, D
    DIEBOLD, B
    FAGON, JY
    SAFAR, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A145 - A145
  • [28] MRI-based Determination of Reference Values of Thoracic Aortic Wall Thickness in a General Population
    Birger Mensel
    Alexander Quadrat
    Tobias Schneider
    Jens-Peter Kühn
    Marcus Dörr
    Henry Völzke
    Wolfgang Lieb
    Katrin Hegenscheid
    Roberto Lorbeer
    European Radiology, 2014, 24 : 2038 - 2044
  • [29] MRI-based Determination of Reference Values of Thoracic Aortic Wall Thickness in a General Population
    Mensel, Birger
    Quadrat, Alexander
    Schneider, Tobias
    Kuehn, Jens-Peter
    Doerr, Marcus
    Voelzke, Henry
    Lieb, Wolfgang
    Hegenscheid, Katrin
    Lorbeer, Roberto
    EUROPEAN RADIOLOGY, 2014, 24 (09) : 2038 - 2044
  • [30] Improvement in Aortic Vascular Inflammation by 18-FDG PET/CT Associates With Reduction in Aortic Wall Thickness by MRI
    Kabbany, Mohammad T.
    Dey, Amit K.
    Shukla, Parag
    Chaturvedi, Abhishek
    Lerman, Joseph B.
    Aberra, Tsion M.
    Joshi, Aditya A.
    Silverman, Joanna I.
    Ng, Qimin
    Teague, Heather L.
    Dahiya, Asha
    Rodante, Justin A.
    Ahlman, Mark A.
    Playford, Martin P.
    Mehta, Nehal N.
    CIRCULATION, 2016, 134