Agreement Between Methods of Measurement of Mean Aortic Wall Thickness by MRI

被引:21
|
作者
Rosero, Eric B. [1 ]
Peshock, Ronald M. [2 ,3 ]
Khera, Amit [3 ]
Clagett, G. Patrick [1 ]
Lo, Hao [2 ]
Timaran, Carlos [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Surg, Div Vasc & Endovasc Surg, Dallas, TX 75390 USA
[2] Univ Texas SW Med Ctr Dallas, Dept Radiol, Donald W Reynolds Cardiovasc Clin Res Ctr, Dallas, TX 75390 USA
[3] Univ Texas SW Med Ctr Dallas, Dept Internal Med, Donald W Reynolds Cardiovasc Clin Res Ctr, Dallas, TX 75390 USA
关键词
wall thickness; cardiovascular MRI; atherosclerosis; HUMAN ATHEROSCLEROTIC LESIONS; INTIMA-MEDIA THICKNESS; MAGNETIC-RESONANCE; HIGH-RESOLUTION; CAROTID-ARTERY; PLAQUE; REPRODUCIBILITY; SIMVASTATIN; STATISTICS; REGRESSION;
D O I
10.1002/jmri.21697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the agreement between three methods of calculation of mean aortic wall thickness (MAWT) using magnetic resonance imaging (MRI). Materials and Methods: High-resolution MRI of the infra-renal abdominal aorta was performed on 70 subjects with a history of coronary artery disease who were part of a multi-ethnic population-based sample. MAWT was calculated as the mean distance between the adventitial and luminal aortic boundaries using three different methods: average distance at four standard positions (AWT-4P). average distance at 100 automated positions (AWT-100P), and using a mathematical computation derived from the total vessel and luminal areas (AWT-VA). Bland-Altman plots and Passing-Bablok regression analyses were used to assess agreement between methods. Results: Bland-Altman analyses demonstrated a positive bias of 3.02 +/- 7.31% between the AWT-VA and the AWT-4P methods, and of 1.76 +/- 6.82% between the WT-100P and the AWT-4P methods. Passing-Bablok regression analyses demonstrated constant bias between the AWT-4P method and the other two methods. Proportional bias was, however, not evident among the three methods. Conclusion: MRI methods of measurement of MAWT using a limited number of positions of the aortic wall systematically underestimate the MAWT value compared with the method that calculates MAWT from the vessel areas.
引用
收藏
页码:576 / 582
页数:7
相关论文
共 50 条
  • [1] Towards Accurate Measurement of Abdominal Aortic Aneurysm Wall Thickness from CT and MRI
    Huynh, Andy T.
    Miller, Karol
    COMPUTATIONAL BIOMECHANICS FOR MEDICINE, 2022, : 3 - 14
  • [2] MEASUREMENT OF AORTIC WALL THICKNESS IN LIVING DOGS
    MARBLE, AE
    MACDONAL.AS
    HOLLAND, JG
    HILLIARD, W
    MILLER, CH
    WINTER, DA
    MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (01): : 39 - 42
  • [3] Assessing Agreement between Methods of Measurement
    Altman, Douglas G.
    Bland, J. Martin
    CLINICAL CHEMISTRY, 2017, 63 (10) : 1653 - 1654
  • [4] Associations between aortic pulse wave velocity and aortic and carotid vessel wall thickness in patients with hypertension: assessment with MRI
    Anne Brandts
    Albert de Roos
    Saskia G van Elderen
    Lucia J Kroft
    Stijntje D Roes
    Johan H Reiber
    Rob J van der Geest
    Jos J Westenberg
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [5] MEASUREMENT OF THE AORTIC WALL THICKNESS USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN PATIENTS WITH AORTIC DISSECTION
    Fanari, Zaher
    Ibrahim, Morhaf
    Hamilton, Andrew
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E2065 - E2065
  • [6] ASSESSING AGREEMENT BETWEEN CLINICAL MEASUREMENT METHODS
    LIEHR, P
    DEDO, YL
    TORRES, S
    MEININGER, JC
    HEART & LUNG, 1995, 24 (03): : 240 - 245
  • [7] Noninvasive ultrasound methods for the measurement of arterial wall thickness
    Girerd, X
    Boutouyrie, P
    Pannier, B
    Mourad, JJ
    Safar, M
    Laurent, S
    INTIMA-MEDIA THICKNESS AN ATHEROSCLEROSIS: PREDICTING THE RISK?, 1997, : 45 - 57
  • [8] Automated measurement of mean wall thickness in the common carotid artery by MRI: A comparison to intima-media thickness by B-mode ultrasound
    Underhill, Hunter R.
    Kerwin, William S.
    Hatsukami, Thomas S.
    Yuan, Chun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (02) : 379 - 387
  • [9] Commentary on quantifying agreement between two methods of measurement
    Altman, DG
    Bland, JM
    CLINICAL CHEMISTRY, 2002, 48 (05) : 801 - 802
  • [10] Mean Thoracic Aortic Wall Thickness Determination by Cine MRI with Steady-State Free Precession: Validation with Dark Blood Imaging
    Mensel, Birger
    Kuehn, Jens-Peter
    Schneider, Tobias
    Quadrat, Alexander
    Hegenscheid, Katrin
    ACADEMIC RADIOLOGY, 2013, 20 (08) : 1004 - 1008