A pocket-sized metabolic analyzer for assessment of resting energy expenditure

被引:20
|
作者
Zhao, Di [1 ]
Xian, Xiaojun [1 ]
Terrera, Mirna [1 ]
Krishnan, Ranganath [1 ,3 ]
Miller, Dylan [1 ,2 ]
Bridgeman, Devon [1 ,2 ]
Tao, Kevin [1 ]
Zhang, Lihua [1 ]
Tsow, Francis [1 ]
Forzani, Erica S. [1 ,2 ]
Tao, Nongjian [1 ,3 ]
机构
[1] Arizona State Univ, Ctr Bioelect & Biosensors, Biodesign Inst, Tempe, AZ 85287 USA
[2] Arizona State Univ, Sch Engn Matter Transport & Energy, Tempe, AZ 85287 USA
[3] Arizona State Univ, Sch Elect Comp & Energy Engn, Tempe, AZ 85287 USA
关键词
Resting energy expenditure; Indirect calorimetry; Oxygen consumption; Carbon dioxide production; Weight management; Fitness; CROSS-VALIDATION; EQUATIONS;
D O I
10.1016/j.clnu.2013.06.001
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background & aims: The assessment of metabolic parameters related to energy expenditure has a proven value for weight management; however these measurements remain too difficult and costly for monitoring individuals at home. The objective of this study is to evaluate the accuracy of a new pocket-sized metabolic analyzer device for assessing energy expenditure at rest (REE) and during sedentary activities (EE). The new device performs indirect calorimetry by measuring an individual's oxygen consumption (VO2) and carbon dioxide production (VCO2) rates, which allows the determination of resting- and sedentary activity-related energy expenditure. Methods: VO2 and VCO2 values of 17 volunteer adult subjects were measured during resting and sedentary activities in order to compare the metabolic analyzer with the Douglas bag method. The Douglas bag method is considered the Gold Standard method for indirect calorimetry. Metabolic parameters of VO2, VCO2, and energy expenditure were compared using linear regression analysis, paired t-tests, and Bland-Altman plots. Results: Linear regression analysis of measured VO2 and VCO2 values, as well as calculated energy expenditure assessed with the new analyzer and Douglas bag method, had the following linear regression parameters (linear regression slope LRS0, and R-squared coefficient, r(2)) with p = 0: LRS0 (SD) = 1.00 (0.01), r(2) = 0.9933 for VO2; LRS0 (SD) = 1.00 (0.01), r(2) = 0.9929 for VCO2; and LRS0 (SD) = 1.00 (0.01), r(2) = 0.9942 for energy expenditure. In addition, results from paired t-tests did not show statistical significant difference between the methods with a significance level of alpha = 0.05 for VO2, VCO2, REE, and EE. Furthermore, the Bland-Altman plot for REE showed good agreement between methods with 100% of the results within +/- 2SD, which was equivalent to <= 10% error. Conclusion: The findings demonstrate that the new pocket-sized metabolic analyzer device is accurate for determining VO2, VCO2, and energy expenditure. (C) 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [21] VIDEO ON A CHIP IS SECRET OF POCKET-SIZED CAMCORDER
    HADFIELD, P
    NEW SCIENTIST, 1994, 143 (1945) : 22 - 22
  • [22] SIMPLE POCKET-SIZED DATA BLENDER FOR SCANS
    LEINS, PA
    BODFISH, RE
    PATTON, DD
    JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (06) : 417 - &
  • [23] POCKET-SIZED PERSONAL AIR CONTAMINANT MONITOR
    TERRY, SC
    ANGELL, JB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 175 (MAR): : 25 - 25
  • [24] AN IMMEDIATE, POCKET-SIZED, PERSONAL ARRHYTHMIA MONITOR
    SISKEN, RB
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 21 - 22
  • [25] MEDIAPOD: A POCKET-SIZED AND PERSONALIZED MULTIMEDIA DESKTOP
    Potter, Shaya
    Laadan, Oren
    Baratto, Ricardo
    Kim, Leonard
    Nieh, Jason
    INTERNATIONAL JOURNAL OF SEMANTIC COMPUTING, 2010, 4 (02) : 181 - 202
  • [26] ROTHEROE AND MITCHELL POCKET-SIZED AIR SAMPLER
    不详
    MACHINERY AND PRODUCTION ENGINEERING, 1974, 125 (3223): : 276 - 276
  • [27] Swallowing assessment in patients with dysphagia: Validity and reliability of a pocket-sized ultrasound system
    Winiker, Katharina
    Hammond, Rebecca
    Thomas, Paige
    Dimmock, Alice
    Huckabee, Maggie-Lee
    INTERNATIONAL JOURNAL OF LANGUAGE & COMMUNICATION DISORDERS, 2022, 57 (03) : 539 - 551
  • [28] Development of a pediatric pocket-sized guide for antimicrobial therapy
    Ahern, John W.
    Corriveau, Michele
    Raszka, William V., Jr.
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2008, 65 (03) : 203 - 205
  • [29] Use of pocket-sized ultrasound device in vascular surgery
    Fagertun, Henriette
    Vapenstad, Cecilie
    Brekken, Reidar
    Dahl, Torbjorn
    TIDSSKRIFT FOR DEN NORSKE LAEGEFORENING, 2020, 140 (06) : 561 - 565
  • [30] Security development of a pocket-sized teleradiology consultation system
    Niinimäki, J
    Holopainen, A
    Kerttula, J
    Reponen, J
    MEDINFO 2001: PROCEEDINGS OF THE 10TH WORLD CONGRESS ON MEDICAL INFORMATICS, PTS 1 AND 2, 2001, 84 : 1266 - 1270