Swallowing assessment in patients with dysphagia: Validity and reliability of a pocket-sized ultrasound system

被引:10
|
作者
Winiker, Katharina [1 ,2 ,3 ]
Hammond, Rebecca [1 ,2 ,4 ]
Thomas, Paige [1 ,2 ,4 ]
Dimmock, Alice [4 ]
Huckabee, Maggie-Lee [1 ,2 ]
机构
[1] Univ Canterbury, Dept Psychol Speech & Hearing, Christchurch, New Zealand
[2] Univ Canterbury, Rose Ctr Stroke Recovery & Res, Christchurch, New Zealand
[3] Swiss Univ Speech & Language Sci SHLR, Dept Res & Dev, Rorschach, Switzerland
[4] Waitemat Dist Hlth Board, Speech Language Therapy, Auckland, New Zealand
关键词
ultrasound; videofluoroscopy; deglutition; dysphagia; validity; reliability; ULTRASONOGRAPHY; DISPLACEMENT;
D O I
10.1111/1460-6984.12703
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Background The use of ultrasound as an adjunct to clinical swallowing evaluation provides quantitative physiological and morphological data. As a low-risk procedure, ultrasound imaging can be performed outside of a medical setting. This is particularly important for patients living in rural areas with restricted access to a hospital. Technical advances have produced pocket-sized ultrasound technology that is more affordable, and therefore within the fiscal reach of most allied health services. Aims To explore the validity and reliability of pocket-sized ultrasound technology in dysphagia assessment. Methods & Procedures Data were acquired from 43 patients with dysphagia using the Clarius ultrasound device. Ultrasound and videofluoroscopic measures of hyoid and laryngeal displacement during liquid and puree swallowing were collected concurrently to quantify correlation and agreement between identical measures derived from the two instruments. Reliability of ultrasound was assessed for measures of hyoid and laryngeal displacement, tongue thickness, and size of the submental muscles in eight patients. Reliability was evaluated for the entire process of data acquisition including scanning and online measurement using an iPad in a clinical setting and for offline measurement on a computer screen to explore environmental influences on reliability. Outcomes & Results Results revealed poor correlation between the measures of interest across instruments. Reliability of the entire process of data acquisition in a clinical setting was insufficient while reliability was more promising for offline measurements. Conclusions & Implications The clinical use of pocket-sized ultrasound devices, such as the Clarius system, for swallowing evaluation is not indicated at this time. Enhanced validity and reliability of the entire process of data acquisition are needed prior to clinical translation of such technology. WHAT THIS PAPER ADDS What is already known on the subject The use of ultrasound allows for radiation-free, non-invasive swallowing assessment. Some data suggest that ultrasound is valid and reliable in the evaluation of swallowing using standard-sized equipment. Insufficient validity and reliability have been reported for pocket-sized ultrasound technology in the assessment of healthy swallowing. What this paper adds to existing knowledge This research is the first to provide validity and reliability data of the pocket-sized Clarius technology in the evaluation of swallowing in patients with dysphagia. Insufficient validity and reliability of online data acquisition in a clinical environment were found. Reliability for offline measurement was more promising. What are the potential or actual clinical implications of this work? The clinical use of pocket-sized ultrasound devices, such as the Clarius system, for swallowing assessment is not indicated at this time.
引用
收藏
页码:539 / 551
页数:13
相关论文
共 50 条
  • [1] Ultrasound: Validity of a Pocket-Sized System in the Assessment of Swallowing
    Winiker, Katharina
    Burnip, Emma
    Gozdzikowska, Kristin
    Guiu Hernandez, Esther
    Hammond, Rebecca
    Macrae, Phoebe
    Huckabee, Maggie-Lee
    DYSPHAGIA, 2021, 36 (06) : 1010 - 1018
  • [2] Ultrasound: Validity of a Pocket-Sized System in the Assessment of Swallowing
    Katharina Winiker
    Emma Burnip
    Kristin Gozdzikowska
    Esther Guiu Hernandez
    Rebecca Hammond
    Phoebe Macrae
    Maggie-Lee Huckabee
    Dysphagia, 2021, 36 : 1010 - 1018
  • [3] Ultrasound: Reliability of a Pocket-Sized System in the Assessment of Swallowing
    Winiker, Katharina
    Burnip, Emma
    Gozdzikowska, Kristin
    Hernandez, Esther Guiu
    Hammond, Rebecca
    Macrae, Phoebe
    Thomas, Paige
    Huckabee, Maggie-Lee
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2021, 64 (08): : 2928 - 2940
  • [4] Validity and reliability of pocket-sized ultrasound devices in measurement of optic nerve sheath diameter in ICU patients
    Uğur Özdemir
    Meltem Çimen
    Tuba Güney
    Gül Gürsel
    Journal of Clinical Monitoring and Computing, 2020, 34 : 597 - 605
  • [5] Validity and reliability of pocket-sized ultrasound devices in measurement of optic nerve sheath diameter in ICU patients
    Ozdemir, Ugur
    Cimen, Meltem
    Guney, Tuba
    Gursel, Gul
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (03) : 597 - 605
  • [6] Assessment of the renal collecting system using a pocket-sized ultrasound device
    Kameda, Toru
    Uebayashi, Kumiko
    Wagai, Kazuko
    Kawai, Fukiko
    Taniguchi, Nobuyuki
    JOURNAL OF MEDICAL ULTRASONICS, 2018, 45 (04) : 577 - 581
  • [7] Assessment of the renal collecting system using a pocket-sized ultrasound device
    Toru Kameda
    Kumiko Uebayashi
    Kazuko Wagai
    Fukiko Kawai
    Nobuyuki Taniguchi
    Journal of Medical Ultrasonics, 2018, 45 : 577 - 581
  • [8] The Validity and Reliability of a Pocket-Sized Ultrasound to Diagnose Distal Radius Fracture and Assess Quality of Closed Reduction
    Lau, Brian C.
    Robertson, Aaron
    Motamedi, Dania
    Lee, Nicolas
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (06): : 420 - 427
  • [9] Pocket-sized Ultrasound for Physical Diagnosis
    Galen, Benjamin T.
    Schnobrich, Daniel J.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2015, 30 (07) : 883 - 883
  • [10] Pocket-sized Ultrasound for Physical Diagnosis
    Benjamin T. Galen
    Daniel J. Schnobrich
    Journal of General Internal Medicine, 2015, 30 : 883 - 883