Swallowing assessment in patients with dysphagia: Validity and reliability of a pocket-sized ultrasound system

被引:10
|
作者
Winiker, Katharina [1 ,2 ,3 ]
Hammond, Rebecca [1 ,2 ,4 ]
Thomas, Paige [1 ,2 ,4 ]
Dimmock, Alice [4 ]
Huckabee, Maggie-Lee [1 ,2 ]
机构
[1] Univ Canterbury, Dept Psychol Speech & Hearing, Christchurch, New Zealand
[2] Univ Canterbury, Rose Ctr Stroke Recovery & Res, Christchurch, New Zealand
[3] Swiss Univ Speech & Language Sci SHLR, Dept Res & Dev, Rorschach, Switzerland
[4] Waitemat Dist Hlth Board, Speech Language Therapy, Auckland, New Zealand
关键词
ultrasound; videofluoroscopy; deglutition; dysphagia; validity; reliability; ULTRASONOGRAPHY; DISPLACEMENT;
D O I
10.1111/1460-6984.12703
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Background The use of ultrasound as an adjunct to clinical swallowing evaluation provides quantitative physiological and morphological data. As a low-risk procedure, ultrasound imaging can be performed outside of a medical setting. This is particularly important for patients living in rural areas with restricted access to a hospital. Technical advances have produced pocket-sized ultrasound technology that is more affordable, and therefore within the fiscal reach of most allied health services. Aims To explore the validity and reliability of pocket-sized ultrasound technology in dysphagia assessment. Methods & Procedures Data were acquired from 43 patients with dysphagia using the Clarius ultrasound device. Ultrasound and videofluoroscopic measures of hyoid and laryngeal displacement during liquid and puree swallowing were collected concurrently to quantify correlation and agreement between identical measures derived from the two instruments. Reliability of ultrasound was assessed for measures of hyoid and laryngeal displacement, tongue thickness, and size of the submental muscles in eight patients. Reliability was evaluated for the entire process of data acquisition including scanning and online measurement using an iPad in a clinical setting and for offline measurement on a computer screen to explore environmental influences on reliability. Outcomes & Results Results revealed poor correlation between the measures of interest across instruments. Reliability of the entire process of data acquisition in a clinical setting was insufficient while reliability was more promising for offline measurements. Conclusions & Implications The clinical use of pocket-sized ultrasound devices, such as the Clarius system, for swallowing evaluation is not indicated at this time. Enhanced validity and reliability of the entire process of data acquisition are needed prior to clinical translation of such technology. WHAT THIS PAPER ADDS What is already known on the subject The use of ultrasound allows for radiation-free, non-invasive swallowing assessment. Some data suggest that ultrasound is valid and reliable in the evaluation of swallowing using standard-sized equipment. Insufficient validity and reliability have been reported for pocket-sized ultrasound technology in the assessment of healthy swallowing. What this paper adds to existing knowledge This research is the first to provide validity and reliability data of the pocket-sized Clarius technology in the evaluation of swallowing in patients with dysphagia. Insufficient validity and reliability of online data acquisition in a clinical environment were found. Reliability for offline measurement was more promising. What are the potential or actual clinical implications of this work? The clinical use of pocket-sized ultrasound devices, such as the Clarius system, for swallowing assessment is not indicated at this time.
引用
收藏
页码:539 / 551
页数:13
相关论文
共 50 条
  • [21] EVALUATION OF A POCKET-SIZED ULTRASOUND DEVICE AS AN AID TO THE PHYSICAL EXAMINATION
    Ojeda, Jason
    Colbert, James
    McMahon, Graham T.
    Benson, Carol
    Doubilet, Peter
    Wu, Justina
    Katz, Joel T.
    Yialamas, Maria
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2013, 28 : S462 - S462
  • [22] Preoperative detection of pleural adhesions using pocket-sized ultrasound
    Sano, Atsushi
    Hiranuma, Ayako
    Nagashima, Makoto
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2021, 29 (05): : 400 - 404
  • [23] The Test of Masticating and Swallowing Solids (TOMASS): Reliability and validity in patients with dysphagia
    Todaro, Francesca
    Pizzorni, Nicole
    Scarponi, Letizia
    Ronzoni, Clara
    Huckabee, Maggie-Lee
    Schindler, Antonio
    INTERNATIONAL JOURNAL OF LANGUAGE & COMMUNICATION DISORDERS, 2021, 56 (03) : 558 - 566
  • [24] Pocket-sized versus standard ultrasound machines in abdominal imaging
    Tse, Ka Hei
    Luk, Wing Hang
    Lam, Mau Chu
    SINGAPORE MEDICAL JOURNAL, 2014, 55 (06) : 325 - 332
  • [25] FAST AUTOMATIC MEASUREMENT OF MITRAL ANNULUS EXCURSION USING A POCKET-SIZED ULTRASOUND SYSTEM
    Snare, Sten Roar
    Mjolstad, Ole Christian
    Orderud, Fredrik
    Haugen, Bjorn Olav
    Torp, Hans
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (04): : 617 - 631
  • [26] Security development of a pocket-sized teleradiology consultation system
    Niinimäki, J
    Holopainen, A
    Kerttula, J
    Reponen, J
    MEDINFO 2001: PROCEEDINGS OF THE 10TH WORLD CONGRESS ON MEDICAL INFORMATICS, PTS 1 AND 2, 2001, 84 : 1266 - 1270
  • [27] Reliability and validity of a low cost, pocket-sized and battery operated sodium analyzer in measuring urinary sodium concentration
    Goulet, Eric D. B.
    Asselin, Audrey
    TECHNOLOGY AND HEALTH CARE, 2015, 23 (06) : 881 - 891
  • [28] USEFULNESS OF ULTRASOUND LUNG COMETS OBTAINED BY A POCKET-SIZED ULTRASOUND DEVICE IN SITTING OUTPATIENTS
    Kamiyama, Tetsuo
    Nishioka, Toshihiko
    Toyama, Kentaro
    Sasaki, Osamu
    Ito, Hiroyuki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E609 - E609
  • [29] A pocket-sized metabolic analyzer for assessment of resting energy expenditure
    Zhao, Di
    Xian, Xiaojun
    Terrera, Mirna
    Krishnan, Ranganath
    Miller, Dylan
    Bridgeman, Devon
    Tao, Kevin
    Zhang, Lihua
    Tsow, Francis
    Forzani, Erica S.
    Tao, Nongjian
    CLINICAL NUTRITION, 2014, 33 (02) : 341 - 347
  • [30] Pocket-Sized Versus Conventional Ultrasound for Detecting Fatty Infiltration of the Liver
    D. A. Miles
    C. S. Levi
    J. Uhanova
    S. Cuvelier
    K. Hawkins
    G. Y. Minuk
    Digestive Diseases and Sciences, 2020, 65 : 82 - 85